hwmon: (mr75203) fix wrong power-up delay value
[ Upstream commit a8d6d4992ad9d92356619ac372906bd29687bb46 ]
In the file mr75203.c we have a macro named POWER_DELAY_CYCLE_256,
the correct value should be 0x100. The register ip_tmr is expressed
in units of IP clk cycles, in accordance with the datasheet.
Typical power-up delays for Temperature Sensor are 256 cycles i.e. 0x100.
Fixes: 9d823351a337 ("hwmon: Add hardware monitoring driver for Moortec MR75203 PVT controller")
Signed-off-by: Arseny Demidov <a.demidov@yadro.com>
Link: https://lore.kernel.org/r/20211219102239.1112-1-a.demidov@yadro.com
Signed-off-by: Guenter Roeck <linux@roeck-us.net>
Signed-off-by: Sasha Levin <sashal@kernel.org>
Diffstat (limited to 'drivers/hwmon')
-rw-r--r-- | drivers/hwmon/mr75203.c | 2 |
1 files changed, 1 insertions, 1 deletions
diff --git a/drivers/hwmon/mr75203.c b/drivers/hwmon/mr75203.c index 868243dba1ee..1ba1e3145969 100644 --- a/drivers/hwmon/mr75203.c +++ b/drivers/hwmon/mr75203.c @@ -93,7 +93,7 @@ #define VM_CH_REQ BIT(21) #define IP_TMR 0x05 -#define POWER_DELAY_CYCLE_256 0x80 +#define POWER_DELAY_CYCLE_256 0x100 #define POWER_DELAY_CYCLE_64 0x40 #define PVT_POLL_DELAY_US 20 |