authorEvgeny Boger <boger@wirenboard.com>2022-01-12 11:47:27 +0300
committerGreg Kroah-Hartman <gregkh@linuxfoundation.org>2022-04-13 21:59:03 +0300
commit793a3704589358ac55e7ec881552b250f384a6ec (patch)
tree65b15aa42228fd686a08e990348a5d292d716244 /drivers/power
parenta0f8220ce93453f31af01dcdb4bd638772b60cc0 (diff)
downloadlinux-793a3704589358ac55e7ec881552b250f384a6ec.tar.xz
power: supply: axp20x_battery: properly report current when discharging
[ Upstream commit d4f408cdcd26921c1268cb8dcbe8ffb6faf837f3 ] As stated in [1], negative current values are used for discharging batteries. AXP PMICs internally have two different ADC channels for shunt current measurement: one used during charging and one during discharging. The values reported by these ADCs are unsigned. While the driver properly selects ADC channel to get the data from, it doesn't apply negative sign when reporting discharging current. [1] Documentation/ABI/testing/sysfs-class-power Signed-off-by: Evgeny Boger <boger@wirenboard.com> Acked-by: Chen-Yu Tsai <wens@csie.org> Signed-off-by: Sebastian Reichel <sebastian.reichel@collabora.com> Signed-off-by: Sasha Levin <sashal@kernel.org>
Diffstat (limited to 'drivers/power')
-rw-r--r--drivers/power/supply/axp20x_battery.c13
1 files changed, 6 insertions, 7 deletions
diff --git a/drivers/power/supply/axp20x_battery.c b/drivers/power/supply/axp20x_battery.c
index 18a9db0df4b1..335e12cc5e2f 100644
--- a/drivers/power/supply/axp20x_battery.c
+++ b/drivers/power/supply/axp20x_battery.c
@@ -186,7 +186,6 @@ static int axp20x_battery_get_prop(struct power_supply *psy,
union power_supply_propval *val)
{
struct axp20x_batt_ps *axp20x_batt = power_supply_get_drvdata(psy);
- struct iio_channel *chan;
int ret = 0, reg, val1;
switch (psp) {
@@ -266,12 +265,12 @@ static int axp20x_battery_get_prop(struct power_supply *psy,
if (ret)
return ret;
- if (reg & AXP20X_PWR_STATUS_BAT_CHARGING)
- chan = axp20x_batt->batt_chrg_i;
- else
- chan = axp20x_batt->batt_dischrg_i;
-
- ret = iio_read_channel_processed(chan, &val->intval);
+ if (reg & AXP20X_PWR_STATUS_BAT_CHARGING) {
+ ret = iio_read_channel_processed(axp20x_batt->batt_chrg_i, &val->intval);
+ } else {
+ ret = iio_read_channel_processed(axp20x_batt->batt_dischrg_i, &val1);
+ val->intval = -val1;
+ }
if (ret)
return ret;