diff options
Diffstat (limited to 'Documentation/devicetree/bindings/timer/arm,sp804.txt')
-rw-r--r-- | Documentation/devicetree/bindings/timer/arm,sp804.txt | 29 |
1 files changed, 0 insertions, 29 deletions
diff --git a/Documentation/devicetree/bindings/timer/arm,sp804.txt b/Documentation/devicetree/bindings/timer/arm,sp804.txt deleted file mode 100644 index 5cd8eee74af1..000000000000 --- a/Documentation/devicetree/bindings/timer/arm,sp804.txt +++ /dev/null @@ -1,29 +0,0 @@ -ARM sp804 Dual Timers ---------------------------------------- - -Required properties: -- compatible: Should be "arm,sp804" & "arm,primecell" -- interrupts: Should contain the list of Dual Timer interrupts. This is the - interrupt for timer 1 and timer 2. In the case of a single entry, it is - the combined interrupt or if "arm,sp804-has-irq" is present that - specifies which timer interrupt is connected. -- reg: Should contain location and length for dual timer register. -- clocks: clocks driving the dual timer hardware. This list should be 1 or 3 - clocks. With 3 clocks, the order is timer0 clock, timer1 clock, - apb_pclk. A single clock can also be specified if the same clock is - used for all clock inputs. - -Optional properties: -- arm,sp804-has-irq = <#>: In the case of only 1 timer irq line connected, this - specifies if the irq connection is for timer 1 or timer 2. A value of 1 - or 2 should be used. - -Example: - - timer0: timer@fc800000 { - compatible = "arm,sp804", "arm,primecell"; - reg = <0xfc800000 0x1000>; - interrupts = <0 0 4>, <0 1 4>; - clocks = <&timclk1 &timclk2 &pclk>; - clock-names = "timer1", "timer2", "apb_pclk"; - }; |