summaryrefslogtreecommitdiff
path: root/meta-ibm/meta-witherspoon/recipes-phosphor/dbus/phosphor-dbus-monitor-config.bbappend
diff options
context:
space:
mode:
authorBrad Bishop <bradleyb@fuzziesquirrel.com>2019-07-18 00:35:55 +0300
committerBrad Bishop <bradleyb@fuzziesquirrel.com>2019-07-24 04:18:54 +0300
commita29c2d5e6187adb2c309d049226085eb1283b555 (patch)
tree0fa19fd4aa4a95779e503e235109b769a013138d /meta-ibm/meta-witherspoon/recipes-phosphor/dbus/phosphor-dbus-monitor-config.bbappend
parentead9ee683e5829b00afae3032df6d4e505f492b6 (diff)
downloadopenbmc-a29c2d5e6187adb2c309d049226085eb1283b555.tar.xz
meta-ibm: use ibm-ac-server MACHINEOVERRIDE
Use an override in bbappends in meta-witherspoon as described and recommended in the "following best practices when creating layers" section of the the Yocto development tasks manual. ibm-ac-server represents common machine configuration shared by all of IBMs "Accelerated Compute" class of servers. Apply it wherever any variables are un-bounded by any override. This enables more flexible use of meta-witherspoon in build configurations, and easy addition of machines to the layer. (From meta-ibm rev: bb0e1d0699a4b9905c053c94af7d882cd71779fc) Change-Id: I82f7338b0d7a64b5e7a67e19bcdff07f48a332d4 Signed-off-by: Brad Bishop <bradleyb@fuzziesquirrel.com>
Diffstat (limited to 'meta-ibm/meta-witherspoon/recipes-phosphor/dbus/phosphor-dbus-monitor-config.bbappend')
-rw-r--r--meta-ibm/meta-witherspoon/recipes-phosphor/dbus/phosphor-dbus-monitor-config.bbappend8
1 files changed, 4 insertions, 4 deletions
diff --git a/meta-ibm/meta-witherspoon/recipes-phosphor/dbus/phosphor-dbus-monitor-config.bbappend b/meta-ibm/meta-witherspoon/recipes-phosphor/dbus/phosphor-dbus-monitor-config.bbappend
index b06da500a..185db1033 100644
--- a/meta-ibm/meta-witherspoon/recipes-phosphor/dbus/phosphor-dbus-monitor-config.bbappend
+++ b/meta-ibm/meta-witherspoon/recipes-phosphor/dbus/phosphor-dbus-monitor-config.bbappend
@@ -1,4 +1,4 @@
-PHOSPHOR_DBUS_MONITOR_CONFIGS_append = " fan-policy"
-PHOSPHOR_DBUS_MONITOR_CONFIGS_append = " thermal-policy"
-PHOSPHOR_DBUS_MONITOR_CONFIGS_append = " power-supply-policy"
-PHOSPHOR_DBUS_MONITOR_CONFIGS_append = " events-policy"
+PHOSPHOR_DBUS_MONITOR_CONFIGS_append_ibm-ac-server = " fan-policy"
+PHOSPHOR_DBUS_MONITOR_CONFIGS_append_ibm-ac-server = " thermal-policy"
+PHOSPHOR_DBUS_MONITOR_CONFIGS_append_ibm-ac-server = " power-supply-policy"
+PHOSPHOR_DBUS_MONITOR_CONFIGS_append_ibm-ac-server = " events-policy"