meta-ampere: mtjade: don't configure OCP GPIO when BMC rebooted
Configure OCP_AUX_PWREN and/or OCP_MAIN_PWREN GPIOs, even without
changing their values, make the OCP power glitched which consequently
makes the Host OS generates many calltrace message.
When BMC is rebooted, the ampere-gpio-poweron@service service is
triggered that reconfigure these GPIOs.
This comit prevents this case by checking if the Host is currently ON to
skip the reconfiguration.
Tested:
1. Boot the BMC and Host CPU.
2. Reboot BMC. Ensure no call trace for OCP
Signed-off-by: Thang Q. Nguyen <thang@os.amperecomputing.com>
Change-Id: I621e025adf72baf84bffd011ea0e04229f739755