wspoon: Enable fan control to run at BMC standby
To allow thermal modes to be selected at BMC standby, the fan control
application must be running. The phosphor-fan-control@.service file is
needed to start fan control at BMC standby and the
phosphor-fan-control-init@.service is no longer required.
Tested:
Witherspoon phosphor-fan-control@.service replaced in image
phosphor-fan-control-init@.service removed from image
fan watchdog configs appended to fan control service still
phosphor-fan-control@.service started at BMC standby
fan control thermal modes presented/changeable at BMC standby
no function change in configured thermal modes
(From meta-ibm rev: f59761e1af85b3ae6432bf0297f5cfe5be71e557)
Change-Id: I4a946f58b6f0c22ebd402304ae9d8fd17a197571
Signed-off-by: Matthew Barth <msbarth@us.ibm.com>
Signed-off-by: Brad Bishop <bradleyb@fuzziesquirrel.com>