phosphor-power: Only build monitor when told to
The 'monitor' package provides a power supply monitor application that
uses an org.open_power phosphor-dbus-interface that is only used
on a subset of the OpenPower systems.
So that non OpenPower systems can use phosphor-power and not need to
include the org.open_power D-Bus interfaces, add a packageconfig option
for this application to turn off its compilation. It will then only be
enabled for certain machines.
Fixes openbmc/phosphor-power#6
Tested:
Built Witherspoon, application still built and installed.
Built Rainier, application not built.
Signed-off-by: Matt Spinler <spinler@us.ibm.com>
Change-Id: Ib7fca16217d93b7d021ba8fb6659e9ddca17d1d9
Diffstat (limited to 'meta-phosphor/recipes-phosphor')
-rw-r--r-- | meta-phosphor/recipes-phosphor/power/phosphor-power_git.bb | 6 |
1 files changed, 5 insertions, 1 deletions
diff --git a/meta-phosphor/recipes-phosphor/power/phosphor-power_git.bb b/meta-phosphor/recipes-phosphor/power/phosphor-power_git.bb index 012b4939e..a01a99752 100644 --- a/meta-phosphor/recipes-phosphor/power/phosphor-power_git.bb +++ b/meta-phosphor/recipes-phosphor/power/phosphor-power_git.bb @@ -41,6 +41,10 @@ DEPENDS += " \ boost \ " +# The monitor package uses an org.open_power D-Bus interface and so +# should only build when told to. +PACKAGECONFIG[monitor] = "-Dsupply-monitor=true, -Dsupply-monitor=false" + SEQ_MONITOR_SVC = "pseq-monitor.service" SEQ_PGOOD_SVC = "pseq-monitor-pgood.service" PSU_MONITOR_TMPL = "power-supply-monitor@.service" @@ -51,7 +55,7 @@ REGS_MON_ENA_SVC = "phosphor-regulators-monitor-enable.service" REGS_MON_DIS_SVC = "phosphor-regulators-monitor-disable.service" SYSTEMD_SERVICE_${PN}-sequencer = "${SEQ_MONITOR_SVC} ${SEQ_PGOOD_SVC}" -SYSTEMD_SERVICE_${PN}-monitor = "${PSU_MONITOR_TMPL}" +SYSTEMD_SERVICE_${PN}-monitor = "${@bb.utils.contains('PACKAGECONFIG', 'monitor', '${PSU_MONITOR_TMPL}', '', d)}" SYSTEMD_SERVICE_${PN}-psu-monitor = "${PSU_MONITOR_SVC}" SYSTEMD_SERVICE_${PN}-regulators = "${REGS_SVC} ${REGS_CONF_SVC} ${REGS_MON_ENA_SVC} ${REGS_MON_DIS_SVC}" |