wspoon: Add cooling-type dep to fan control
With commit c184a0f08, the phosphor-hwmon instance for the max31785 fan
control device no longer waited for the cooling-type application to
finish before starting. Since the fan control service depends on the
phosphor-hwmon instance, it is now starting earlier than before, before
cooling-type, which was causing a crash.
To fix this, add the cooling-type dependency into the witherspoon fan
control service file.
Tested: Can see in the journal that fan control now starts after
phosphor-cooling-type, and it doesn't crash on a genesis reboot when the
inventory had previously been cleared.
Signed-off-by: Matt Spinler <spinler@us.ibm.com>
Change-Id: I4bf9d8eb7f39acea71b790a61edfe1e8c4dae788