diff --git a/meta-ibm/meta-witherspoon/recipes-phosphor/sensors/phosphor-hwmon/witherspoon-tacoma/obmc/hwmon/ahb/apb/bus@1e78a000/i2c-bus@300/ir35221@70.conf b/meta-ibm/meta-witherspoon/recipes-phosphor/sensors/phosphor-hwmon/witherspoon-tacoma/obmc/hwmon/ahb/apb/bus@1e78a000/i2c-bus@300/ir35221@70.conf
deleted file mode 100644
index e7d8aaf23..000000000
--- a/meta-ibm/meta-witherspoon/recipes-phosphor/sensors/phosphor-hwmon/witherspoon-tacoma/obmc/hwmon/ahb/apb/bus@1e78a000/i2c-bus@300/ir35221@70.conf
+++ /dev/null
@@ -1,65 +0,0 @@
-#5-0070
-#VDD then VCS
-
-MODE_in1 = "label"
-MODE_in2 = "label"
-MODE_in3 = "label"
-MODE_in4 = "label"
-
-MODE_curr1 = "label"
-MODE_curr2 = "label"
-MODE_curr3 = "label"
-MODE_curr4 = "label"
-
-MODE_power1 = "label"
-MODE_power2 = "label"
-MODE_power3 = "label"
-MODE_power4 = "label"
-
-LABEL_temp1 = "p1_vdd_temp"
-WARNHI_temp1 = "80000"
-WARNLO_temp1 = "0"
-CRITHI_temp1 = "85000"
-CRITLO_temp1 = "0"
-
-LABEL_curriout1 = "p1_vdd_current"
-WARNLO_curriout1 = "0"
-CRITLO_curriout1 = "0"
-WARNHI_curriout1 = "320000"
-CRITHI_curriout1 = "360000"
-
-LABEL_invout1 = "p1_vdd_voltage"
-WARNLO_invout1 = "0"
-CRITLO_invout1 = "0"
-WARNHI_invout1 = "1150"
-CRITHI_invout1 = "1300"
-
-LABEL_powerpout1 = "p1_vdd_power"
-WARNLO_powerpout1 = "0"
-CRITLO_powerpout1 = "0"
-WARNHI_powerpout1 = "270000000"
-CRITHI_powerpout1 = "290000000"
-
-LABEL_temp2 = "p1_vcs_temp"
-WARNHI_temp2 = "80000"
-WARNLO_temp2 = "0"
-CRITHI_temp2 = "85000"
-CRITLO_temp2 = "0"
-
-LABEL_curriout2 = "p1_vcs_current"
-WARNLO_curriout2 = "0"
-CRITLO_curriout2 = "0"
-WARNHI_curriout2 = "20000"
-CRITHI_curriout2 = "25000"
-
-LABEL_invout2 = "p1_vcs_voltage"
-WARNLO_invout2 = "0"
-CRITLO_invout2 = "0"
-WARNHI_invout2 = "1150"
-CRITHI_invout2 = "1300"
-
-LABEL_powerpout2 = "p1_vcs_power"
-WARNLO_powerpout2 = "0"
-CRITLO_powerpout2 = "0"
-WARNHI_powerpout2 = "20000000"
-CRITHI_powerpout2 = "25000000"