diff options
Diffstat (limited to 'meta-ibm/recipes-phosphor/fans/phosphor-fan_%.bbappend')
-rw-r--r-- | meta-ibm/recipes-phosphor/fans/phosphor-fan_%.bbappend | 59 |
1 files changed, 59 insertions, 0 deletions
diff --git a/meta-ibm/recipes-phosphor/fans/phosphor-fan_%.bbappend b/meta-ibm/recipes-phosphor/fans/phosphor-fan_%.bbappend new file mode 100644 index 000000000..713c0c6a2 --- /dev/null +++ b/meta-ibm/recipes-phosphor/fans/phosphor-fan_%.bbappend @@ -0,0 +1,59 @@ +FILESEXTRAPATHS_prepend := "${THISDIR}/${BPN}:" + +# Package configuration +FAN_PACKAGES_append_ibm-ac-server = " \ + phosphor-cooling-type \ + " + +FAN_PACKAGES_append_mihawk = " \ + phosphor-cooling-type \ + " + +PACKAGECONFIG_append_ibm-ac-server = " cooling-type" +PACKAGECONFIG_append_mihawk = " cooling-type" + +TMPL_COOLING = "phosphor-cooling-type@.service" +INSTFMT_COOLING = "phosphor-cooling-type@{0}.service" +MULTI_USR_TGT = "multi-user.target" +FMT_COOLING = "../${TMPL_COOLING}:${MULTI_USR_TGT}.requires/${INSTFMT_COOLING}" + +FILES_phosphor-cooling-type_append_ibm-ac-server = " ${bindir}/phosphor-cooling-type" +SYSTEMD_SERVICE_phosphor-cooling-type_append_ibm-ac-server = " ${TMPL_COOLING}" +SYSTEMD_LINK_phosphor-cooling-type_append_ibm-ac-server = " ${@compose_list(d, 'FMT_COOLING', 'OBMC_CHASSIS_INSTANCES')}" +FILES_phosphor-cooling-type_append_mihawk = " ${bindir}/phosphor-cooling-type" +SYSTEMD_SERVICE_phosphor-cooling-type_append_mihawk = " ${TMPL_COOLING}" +SYSTEMD_LINK_phosphor-cooling-type_append_mihawk = " ${@compose_list(d, 'FMT_COOLING', 'OBMC_CHASSIS_INSTANCES')}" + +COOLING_ENV_FMT = "obmc/phosphor-fan/phosphor-cooling-type-{0}.conf" + +SYSTEMD_ENVIRONMENT_FILE_phosphor-cooling-type_append_ibm-ac-server = " ${@compose_list(d, 'COOLING_ENV_FMT', 'OBMC_CHASSIS_INSTANCES')}" +SYSTEMD_ENVIRONMENT_FILE_phosphor-cooling-type_append_mihawk = " ${@compose_list(d, 'COOLING_ENV_FMT', 'OBMC_CHASSIS_INSTANCES')}" + +#These services are protected by the watchdog +SYSTEMD_OVERRIDE_phosphor-fan-control_witherspoon += "fan-watchdog-monitor.conf:phosphor-fan-control-init@0.service.d/fan-watchdog-monitor.conf" +SYSTEMD_OVERRIDE_phosphor-fan-control_witherspoon += "fan-watchdog-monitor.conf:phosphor-fan-control@0.service.d/fan-watchdog-monitor.conf" +SYSTEMD_OVERRIDE_phosphor-fan-monitor_witherspoon += "fan-watchdog-monitor.conf:phosphor-fan-monitor-init@0.service.d/fan-watchdog-monitor.conf" +SYSTEMD_OVERRIDE_phosphor-fan-monitor_witherspoon += "fan-watchdog-monitor.conf:phosphor-fan-monitor@0.service.d/fan-watchdog-monitor.conf" + +#These services need to be stopped when watchdog expires +SYSTEMD_OVERRIDE_phosphor-fan-control_witherspoon += "fan-watchdog-conflicts.conf:phosphor-fan-control@0.service.d/fan-watchdog-conflicts.conf" +SYSTEMD_OVERRIDE_phosphor-fan-monitor_witherspoon += "fan-watchdog-conflicts.conf:phosphor-fan-monitor@0.service.d/fan-watchdog-conflicts.conf" + +# Witherspoon fan control service linking +# Link fan control init service +SYSTEMD_LINK_${PN}-control_witherspoon += "${@compose_list(d, 'FMT_CONTROL_INIT', 'OBMC_CHASSIS_INSTANCES')}" +# Link fan control service to be started at standby +FMT_CONTROL_STDBY_witherspoon = "../${TMPL_CONTROL}:${MULTI_USR_TGT}.wants/${INSTFMT_CONTROL}" +SYSTEMD_LINK_${PN}-control_witherspoon += "${@compose_list(d, 'FMT_CONTROL_STDBY', 'OBMC_CHASSIS_INSTANCES')}" +# Link fan control service to also start at poweron +FMT_CONTROL_PWRON_witherspoon = "../${TMPL_CONTROL}:${POWERON_TGT}.requires/${INSTFMT_CONTROL}" +SYSTEMD_LINK_${PN}-control_witherspoon += "${@compose_list(d, 'FMT_CONTROL_PWRON', 'OBMC_CHASSIS_INSTANCES')}" + +# Enable the use of JSON on the fan applications that support it +EXTRA_OECONF_append_witherspoon = " --enable-json" +RDEPENDS_${PN}-presence-tach_append_witherspoon = " phosphor-fan-presence-config" + +# Set the appropriate i2c address used within the overridden phosphor-fan-control@.service +# file that's used for witherspoon type(including witherspoon-tacoma) machines +SYSTEMD_SUBSTITUTIONS_witherspoon = "ADDR:100:phosphor-fan-control@.service" +SYSTEMD_SUBSTITUTIONS_witherspoon-tacoma = "ADDR:200:phosphor-fan-control@.service" |