Age | Commit message (Collapse) | Author | Files | Lines |
|
Update to Version 1.8.5 for mihawk
(From meta-ibm rev: bf39d8f7981252cf0a56f75fd7e5533a828ceb08)
Change-Id: Ief4321ca06d729b6b735532c1a03265c63ab0d5d
Signed-off-by: Ben Pai <Ben_Pai@wistron.com>
Signed-off-by: Brad Bishop <bradleyb@fuzziesquirrel.com>
|
|
Added the BMC inventory for mihawk.
(From meta-ibm rev: 95efbf1fdb48951294a3832137d4c1a56fcab3a2)
Change-Id: I3478e33ce305324d2041e69d79d8873585cae23d
Signed-off-by: Ben Pai <Ben_Pai@wistron.com>
Signed-off-by: Brad Bishop <bradleyb@fuzziesquirrel.com>
|
|
This commit enables the configure option "enable-ibm-dbus-interfaces"
for phosphor-dbus-interfaces build to pull in all com.ibm.*
interfaces.
Tested:
Bitbaked to ensure the right configure options are passed.
(From meta-ibm rev: 8a2fdae730a41fb96887b6d404679800a9f74c8d)
Signed-off-by: Santosh Puranik <santosh.puranik@in.ibm.com>
Change-Id: I788ad7ce6e4e92567176f6dda235f6689d577260
Signed-off-by: Brad Bishop <bradleyb@fuzziesquirrel.com>
|
|
Enable the use of JSON and install the fan presence JSON config file
into the witherspoon image. The other fan applications will continue to
use their respective YAML build time config file(s).
Tested:
Built witherspoon image, uses JSON config
Built mihawk image, continues to use YAML
(From meta-ibm rev: a6817ca6ca8c87a10eb325835ba4db59109f6101)
Change-Id: I1b675e8a3b064b04007d7474d12e5d5ad2094dad
Signed-off-by: Matthew Barth <msbarth@us.ibm.com>
Signed-off-by: Brad Bishop <bradleyb@fuzziesquirrel.com>
|
|
JSON config file representing the same configuration that is given as
YAML at build time.
(From meta-ibm rev: 7e31e7a23d51757132e4d74873a16c65f2a1400b)
Change-Id: I8cb2697d93d402bb66f5967cba913e071a16f6b7
Signed-off-by: Matthew Barth <msbarth@us.ibm.com>
Signed-off-by: Brad Bishop <bradleyb@fuzziesquirrel.com>
|
|
Currently mihawk is missing information about dev id.
(From meta-ibm rev: 28bafefc05285df52eab617ea2158b3886dc93a8)
Change-Id: I02b138a1830e0c4627c70b338d31cb7dbaa2d75c
Signed-off-by: Ben Pai <Ben_Pai@wistron.com>
Signed-off-by: Brad Bishop <bradleyb@fuzziesquirrel.com>
|
|
This will be used so that during manufacturing test the PEL (Platform
Event Log) code that runs inside phosphor-log-manager can be told not to
send PELs to the host as that is not desired in some cases.
The D-Bus path is: /xyz/openbmc_project/logging/send_event_logs_to_host
and it uses the xyz.openbmc_project.Object.Enable interface that
provides an Enabled property. The default value is Enabled = true.
(From meta-ibm rev: 42cd2d857eb1d1c4ae6fdd8c9ee6c3c8de5ef7a0)
Signed-off-by: Matt Spinler <spinler@us.ibm.com>
Change-Id: I9cab4f1c1efdda3a6d3f6f38f7c3e19690f452c2
Signed-off-by: Brad Bishop <bradleyb@fuzziesquirrel.com>
|
|
Support to set the value for ClearSecurityKeys property which can be used to
indicate when certain security keys need to be cleared or reset those values
back to its default state from the system by the host. This property is mapped
to an IPMI sensor and default value will be zero. Setting this property does
not gurantee a successful operation as additional conditions like the physical
presence pin or jumper settings will be checked by the host to clear/reset the
sensitive data.
Tested: Verified that the property is getting created with the expected
default value as zero and can be updated to different values using ipmitool
or busctl command.
1. Default value output:
busctl get-property xyz.openbmc_project.Settings
/org/open_power/control/host0/ClearHostSecurityKeys
org.open_power.Control.TPM.SecurityKeys ClearHostSecurityKeys
y 0
ipmitool -I lanplus -H 9.3.185.33 -U root -P 0penBmc raw 0x04 0x2D 0xE8
00 40 00 00
2. Set to a new value as 5 using busctl command:
busctl set-property xyz.openbmc_project.Settings
/org/open_power/control/host0/ClearHostSecurityKeys
org.open_power.Control.TPM.SecurityKeys ClearHostSecurityKeys y 5
3. After setting to a new value as 5:
ipmitool -I lanplus -H 9.3.185.33 -U root -P 0penBmc raw 0x04 0x2D 0xE8
05 40 00 00
4. ipmitool command to set the value as 4
ipmitool -I lanplus -H 9.3.185.33 -U root -P 0penBmc raw 0x04 0x30 0xE8
0x00 0x04 0x00 0x00 0x00 0x00 0x00 0x00 0x00
ipmitool -I lanplus -H 9.3.185.33 -U root -P 0penBmc raw 0x04 0x2D 0xE8
09 40 00 00
5. Invalid value test o/p:
ipmitool -I lanplus -H 9.3.185.33 -U root -P 0penBmc raw 0x04 0x30 0xE8
0x00 0x12C 0x00 0x00 0x00 0x00 0x00 0x00 0x00
Given data "0x12C" is invalid.
(From meta-ibm rev: 81a9143100d5d4a7d97350afa1794be694d45590)
Signed-off-by: Jayashankar Padath <jayashankar.padath@in.ibm.com>
Change-Id: I9e12b6e5abb3a9b198921847605a74b771fd9945
Signed-off-by: Brad Bishop <bradleyb@fuzziesquirrel.com>
|
|
Tacoma was missing the OBMC_POWER_SUPPLY_INSTANCES config, and thus the
power supply monitor service will not start correctly.
And with the change in
https://gerrit.openbmc-project.xyz/c/openbmc/meta-phosphor/+/27463
the build will fail on constructing the rootfs.
Fix it by adding OBMC_POWER_SUPPLY_INSTANCES in tacoma config.
(From meta-ibm rev: 1f2b96d73f0117b9c07ce7e4beca0e1dfddfb8e2)
Change-Id: I20f1ca81642bb1d594aa783ca3872b6bd08720da
Signed-off-by: Lei YU <mine260309@gmail.com>
Signed-off-by: Brad Bishop <bradleyb@fuzziesquirrel.com>
|
|
HW CI on Palmetto trigers two issues:
1. The case to verify occ active fails because it was using the last
character of `cpux` for occ, e.g. cpu0 -> occ0.
Palmetto had an incorrect inventory path of `cpu`, which results in
`occu`, and it becomes an incorrect path, and the case gets a 404
error while trying to get the OCC active state.
2. The case to get https://$bmc/ fails, it's expecting HTTP 200 OK
resonse, but got a 401 error. This is because webui is not built into
Palmetto, so there is no page, and bmcweb returns 401 for such case.
Fix the above cases.
Tested: Verify the HW CI succeeds on Palmetto:
python3 -m robot -v OPENBMC_HOST:palmetto --argumentfile \
test_lists/HW_CI --exclude Verify_Redfish_Host_PowerOn --include \
Verify_Redfish_Host_PowerOn_No_Check_Watts redfish tests
(From meta-ibm rev: 4ac52cb28db30f89bdfd23ab1614f71b65dfdceb)
Signed-off-by: Lei YU <mine260309@gmail.com>
Change-Id: Ifd102f167cfa4d83769fb055b883e4c214a27b9a
Signed-off-by: Brad Bishop <bradleyb@fuzziesquirrel.com>
|
|
The yaml add the "xyz.openbmc_project.Inventory.Item.Chassis" interface
to "/xyz/openbmc_project/inventory/system/chassis" object.
This is needed for bmcweb to correctly get the chassis id in
/redfish/v1/Chassis/.
Tested: Verify that /redfish/v1/Chassis/chassis exists on Palmetto with
this change. It was 404 without this change.
(From meta-ibm rev: 5930fdcc620b5ab65418b748b3cc0db465dc05fb)
Signed-off-by: Lei YU <mine260309@gmail.com>
Change-Id: I67d5458d4540feacc67bd558dabb642b377f508b
Signed-off-by: Brad Bishop <bradleyb@fuzziesquirrel.com>
|
|
The yaml add the "xyz.openbmc_project.Inventory.Item.Chassis" interface
to "/xyz/openbmc_project/inventory/system/chassis" object.
This is needed for bmcweb to correctly get the chassis id in
/redfish/v1/Chassis/.
Tested: Verify that /redfish/v1/Chassis/chassis exists on Romulus with
this change. It was 404 without this change.
(From meta-ibm rev: 41b829feead473e5541f7d4c3c075e2b1a525c45)
Signed-off-by: Lei YU <mine260309@gmail.com>
Change-Id: Ie091ad32315fb4b4e45d8b35966a7a238dd1d539
Signed-off-by: Brad Bishop <bradleyb@fuzziesquirrel.com>
|
|
Currently avsbus-disable will be executed after power_up to 1.
We found that this will cause power on fail, so avsbus-disable should
be performed before power on.
(From meta-ibm rev: c569a42895ac035837f1508d14903cfea3c5a675)
Change-Id: Ib08573efbb1abf510b2683afd31cd74db9f66a2b
Signed-off-by: Ben Pai <Ben_Pai@wistron.com>
Signed-off-by: Brad Bishop <bradleyb@fuzziesquirrel.com>
|
|
Reviewing GPIO function with engineering, BMC_DCM_ALL_RESET_N GPIO
should be handled differently. Remove BMC_DCM_ALL_RESET_N from Rainier
power-on GPIO configuration.
(From meta-ibm rev: de595e38e6c38729d7e0c7eb6925fe639cbb5b85)
Signed-off-by: Jim Wright <jlwright@us.ibm.com>
Change-Id: I2fa2949b49d192b0a3a6a516c3ce9c49052dd3d7
Signed-off-by: Brad Bishop <bradleyb@fuzziesquirrel.com>
|
|
The power-supply-monitor configs were installed by
SYSTEMD_ENVIRONMENT_FILE_${PN}, which is defined in
obmc-phosphor-systemd.bbclass.
phosphor-power recipe does not inherit obmc-phosphor-systemd, results in
the files installed by SYSTEMD_ENVIRONMENT_FILE_${PN} are not installed
at all.
Fix this issue by inherit obmc-phosphor-systemd in the bbappend.
Tested: Verify the witherspoon build includes the power-supply-monitor
configs.
(From meta-ibm rev: d4374bf93e5927ccadb9de954384096ffb8590ec)
Change-Id: Iaa3a04694c7b591d349a32529a0afef16239203d
Signed-off-by: Lei YU <mine260309@gmail.com>
Signed-off-by: Brad Bishop <bradleyb@fuzziesquirrel.com>
|
|
Although 6 fanx_1 pwm targets are deleted, but fan0_1 fan1_1 and fan2_1
will have a default value that causes the issue to remain unresolved.
In this way, two Fans control the same pwm, but I think that our
current fan control event is controlled at the same time, so it does
not affect the fan control.
(From meta-ibm rev: c4ec0f10a091fe74f075d2033fe055b5bbd7d498)
Change-Id: I42647c92ffe5e20430cee28de6fd26e2716153d9
Signed-off-by: Ben Pai <Ben_Pai@wistron.com>
Signed-off-by: Brad Bishop <bradleyb@fuzziesquirrel.com>
|
|
Set warning and critical values for PSU.
(From meta-ibm rev: 1b9796d85dd41e8675d0d03132cbff8dd74a1d47)
Change-Id: Ie16955f7548e9e6fa54cea2aff767a164abb76f3
Signed-off-by: Ben Pai <Ben_Pai@wistron.com>
Signed-off-by: Brad Bishop <bradleyb@fuzziesquirrel.com>
|
|
Add led fault event, fault led will turn on when cpu or dimm or other
components fail
(From meta-ibm rev: f0aaa6f39f61366a6599d1e571f1eada4bf93b1c)
Change-Id: Ifdd49dab35d915cb7d9ff095e6571fba42801bba
Signed-off-by: Ben Pai <Ben_Pai@wistron.com>
Signed-off-by: Brad Bishop <bradleyb@fuzziesquirrel.com>
|
|
Mihawk's GPU temperature exceeds 92 degrees Celcius should be shutsown
to avoid GPU damage.
Tested:
GPU temperature exceeds 92 degrees Celcius system will shutdown.
(From meta-ibm rev: 623eb4dda626dd3dfb3f14d9afa4e10c86d3bbca)
Change-Id: Id085afa2a7d7a29a42cd5d508a03fb64dd53c108
Signed-off-by: Ben Pai <Ben_Pai@wistron.com>
Signed-off-by: Brad Bishop <bradleyb@fuzziesquirrel.com>
|
|
Currently power sensor might get the wrong channel.
We have to modify it to the correct channel.
Tested:
Check sensot list user can see the correct power sensor.
(From meta-ibm rev: aaceadff166052bef63b860063ccbda66d918629)
Change-Id: I2595c727915b8e72af4f56e5383efb183e9b3638
Signed-off-by: Ben Pai <Ben_Pai@wistron.com>
Signed-off-by: Brad Bishop <bradleyb@fuzziesquirrel.com>
|
|
Fan speed can be increased when occ or ambient is abnormal, so add the
monitor of the ambient and OCC control services.
(From meta-ibm rev: d0a123bdd618570e585a4020593bf9b13395398d)
Change-Id: I17eb679760c2e6f6002f5ea54f7d799f1c62680c
Signed-off-by: Ben Pai <Ben_Pai@wistron.com>
Signed-off-by: Brad Bishop <bradleyb@fuzziesquirrel.com>
|
|
According to our thermal team test report, we need to adjust the fan
control event.
Tested
Fan speed will be based on new fan control events.
(From meta-ibm rev: f242630e5a8195eeef089f01537b9be4fde000a2)
Signed-off-by: Ben Pai <Ben_Pai@wistron.com>
Change-Id: Ib4c296f128d625e78387cead26c46c76faa39535
Signed-off-by: Brad Bishop <bradleyb@fuzziesquirrel.com>
|
|
We think fan is a necessary sensor in ipmi sensor list.
Tested: Use ipmitool sdr to check it.
(From meta-ibm rev: 5bdc8591ac5e6ce708fdc0788806cb89452c3b14)
Change-Id: I87acef1dcfe11bc532eac5412375133b56f40320
Signed-off-by: Ben Pai <Ben_Pai@wistron.com>
Signed-off-by: Brad Bishop <bradleyb@fuzziesquirrel.com>
|
|
1. According to the thermal team test results, the cpu core should be
shutdown when it exceeds 95 degrees Celcius.
2.mihawk's ambient temperature exceeds 45 degrees Celcius should be
shutsown to avoid system damage.
Tested:
Cpu core exceeds 95 degrees Celcius or ambient exceeds 45 degrees
Celcius system will shutdown.
(From meta-ibm rev: 7f94a4b3a7c3d7346ae4b1bade6287ea1a70c41a)
Signed-off-by: Ben Pai <Ben_Pai@wistron.com>
Change-Id: I303a5047dc0b29e46829f4b838eaa6f151b13735
Signed-off-by: Brad Bishop <bradleyb@fuzziesquirrel.com>
|
|
Mihawk Every fan has two rotors but one of the rotors gets the wrong
fan pwm via REST command, so remove fanx_1 target.
Tested: Use command "curl -k -X GET https://root:0penBmc@<ip>/xyz/
openbmc_project/sensors/fan_tach/fan0_0"
This can show the correct pwm.
(From meta-ibm rev: 31a8e8430b5f2629249f80de7eb91b598fa6caca)
Signed-off-by: Ben Pai <Ben_Pai@wistron.com>
Change-Id: I68e40fefdc15a7580ca819084929813dae5d43a5
Signed-off-by: Brad Bishop <bradleyb@fuzziesquirrel.com>
|
|
Matt Spinler (1):
Updates for new association interface
(From meta-ibm rev: 19ce1444820160d3024e292e7863c9601508714a)
Change-Id: If1ab86647f0b8b90d72398d929e67cf16eaff1cc
Signed-off-by: Andrew Geissler <openbmcbump-github@yahoo.com>
Signed-off-by: Brad Bishop <bradleyb@fuzziesquirrel.com>
|
|
There isn't much content here and there hasn't been any activity in this
layer since it was added over a year ago. Drop from the tree.
(From meta-ibm rev: cff4a62a4f634cd6b0107a48ee631346c2246f33)
Change-Id: I32b8c0b965c6e12023329f490989ec1ecd7c966f
Signed-off-by: Brad Bishop <bradleyb@fuzziesquirrel.com>
|
|
The workarounds script does some unbinding and rebinding of the ucd
driver so ensure all of this is done before power is considered
officially on. Other services start after the power on target completes
and they depend on the ucd driver being bound and available.
Tested:
Verified on a system that was failing due to this issue now powers on
(From meta-ibm rev: b95b2f401bd37e0257c50d781e528d00962bbe0f)
Signed-off-by: Andrew Geissler <geissonator@yahoo.com>
Change-Id: I62219e15834506b9935c3a42431d991e3555e64c
Signed-off-by: Brad Bishop <bradleyb@fuzziesquirrel.com>
|
|
Add pldm to witherspoon system and install configs.
(From meta-ibm rev: 6f22923fcae11a46e1c21ac5eba23590d632ed7f)
Signed-off-by: Deepak Kodihalli <dkodihal@in.ibm.com>
Change-Id: I47cfd20eee48afaf4cf985678a0177044852372d
Signed-off-by: Brad Bishop <bradleyb@fuzziesquirrel.com>
|
|
When Rainier was removed from AC server builds, the phosphor-power
repository was dropped from the image. Add phosphor-power to Rainer
builds.
(From meta-ibm rev: 5bbf75e279cfd7d3cf77b8d49c69fe338f97ee72)
Signed-off-by: Jim Wright <jlwright@us.ibm.com>
Change-Id: I9c0105396d9b50d65abc2338eab46ae84bee209e
Signed-off-by: Brad Bishop <bradleyb@fuzziesquirrel.com>
|
|
phosphor-power recipe is added in meta-phosphor, replace
witherspoon-pfault-analysis with phosphor-power.
Add "psuDevices" in psu.json for witherspoon and swift.
Tested: Verify witherspoon build is OK, the phosphor-power related
binaries and the services are installed correctly.
(From meta-ibm rev: 9422171d261d155b903295cd7c0c5aedbab535a0)
Change-Id: I2706ac9e9bff11b943ae6861bebd67e67d0bee15
Signed-off-by: Lei YU <mine260309@gmail.com>
Signed-off-by: Brad Bishop <bradleyb@fuzziesquirrel.com>
|
|
Update rainier.conf to indicate the four power supply instances.
Update bbappend for Rainier SYSTEMD_LINK and SYSTEMD_ENVIRONMENT_FILE.
Add in subdirectory and power supply configuration files for GPIO
presence detect of the Rainier power supplies.
Use aspeed-gpio.sh from https://github.com/bradbishop/gpio-keys to
determine gpio-key values. Use 7-bit I2C addresses on BMC.
+-----+--------+----------+----+
| PSU | GPIO | gpio-key | AA |
+-----+--------+----------+----+
| ps0 | GPIOS0 | 144 | 68 |
+-----+--------+----------+----+
| ps1 | GPIOS1 | 145 | 69 |
+-----+--------+----------+----+
| ps2 | GPIOS2 | 146 | 6a |
+-----+--------+----------+----+
| ps3 | GPIOS3 | 147 | 6b |
+-----+--------+----------+----+
(From meta-ibm rev: 3e8f174546cf440fda56ce47523030d4d403edbd)
Change-Id: Ia55f80e4d857e7a477385d73c12f9719e3065f95
Signed-off-by: Brandon Wyman <bjwyman@gmail.com>
Signed-off-by: Brad Bishop <bradleyb@fuzziesquirrel.com>
|
|
1.Correct the channel of mihawk total power sensor
2.The current mihawk is not used to external gpu power.
Avoid confusing users so delete this sensor.
(From meta-ibm rev: e65b464ca953a0d1a7db93598956db6aa2d306b9)
Change-Id: Ib4dee8181376d848364c9e92b2b5d2e67ec1fc17
Signed-off-by: Ben Pai <Ben_Pai@wistron.com>
Signed-off-by: Brad Bishop <bradleyb@fuzziesquirrel.com>
|
|
Base hardware enablement support for meta-palmetto is provided by
meta-palmetto and meta-openpower. meta-ibm adds advanced serviceability
functions for IBM branded products backed by the IBM service structure.
Palmetto is a reference platform for ODMs and/or OEMS building POWER8
based systems. End users cannot purchase support contracts for Palmetto
systems. As such remove meta-ibm from the build configuration in the
spirit of keeping the reference implementation mini and simplified.
At a functional level this removes the ibm-logging application from
images.
Note that meta-ibm can always be re-integrated by simply adding it to
bblayers.conf
(From meta-ibm rev: 37a17426e42ecfc843e757732b01a81212a109e7)
Change-Id: Ic0ea8778b249ae14f21093157793c046e2c1de81
Signed-off-by: Brad Bishop <bradleyb@fuzziesquirrel.com>
|
|
Gunnar Mills (1):
Update sensor-architecture.md link
Jim Wright (2):
Make GPIOAnalysis section optional in power sequencer YAML
Update example power sequencer YAML
Shawn McCarney (4):
Create stubs for regulator Device, Rail, and Rule
Conform regulator methods to acronym conventions
Add explicit keyword to regulator constructors
Create regulators IDMap class
(From meta-ibm rev: 5f84ff75820207d4fb64979c303b719de971b453)
Change-Id: If52910de726d3083da3b4e1b0142650f30dc2988
Signed-off-by: Andrew Geissler <openbmcbump-github@yahoo.com>
Signed-off-by: Brad Bishop <bradleyb@fuzziesquirrel.com>
|
|
In the Witherspoon power sequencer YAML, the device path contains an
extra forward slash. Remove the unneed character.
(From meta-ibm rev: a68a95377dbee8779eeb5174e07f62cf335ce37b)
Signed-off-by: Jim Wright <jlwright@us.ibm.com>
Change-Id: I40d368bd36b573c000ec9352350e3a0f7c1a1926
Signed-off-by: Brad Bishop <bradleyb@fuzziesquirrel.com>
|
|
Following https://gerrit.openbmc-project.xyz/c/openbmc/phosphor-power/+/26667,
the GPIOAnalysis section is optional and unneeded on Rainier. Remove dummy
entry.
(From meta-ibm rev: 3b36c0bf33426ea4a900287619ae13054ac8f810)
Signed-off-by: Jim Wright <jlwright@us.ibm.com>
Change-Id: I02048ff2fa8a07dc89787939b4241381460c3166
Signed-off-by: Brad Bishop <bradleyb@fuzziesquirrel.com>
|
|
Base hardware enablement support for meta-romulus is provided by
meta-romulus and meta-openpower. meta-ibm adds advanced serviceability
functions for IBM branded products backed by the IBM service structure.
Romulus is a reference platform for ODMs and/or OEMS building POWER9
based systems. End users cannot purchase support contracts for Romulus
systems. As such remove meta-ibm from the build configuration in the
spirit of keeping the reference implementation mini and simplified.
At a functional level this removes the ibm-logging application from
images.
Note that meta-ibm can always be re-integrated by simply adding it to
bblayers.conf
(From meta-ibm rev: c8cb279e0a8e9d941d8a73f04496a81e0efd5501)
Change-Id: Ie657468f2566042c5faad9ae5a7923a2f9222564
Signed-off-by: Brad Bishop <bradleyb@fuzziesquirrel.com>
|
|
iKVM is not supported on Swift machines now.
(From meta-ibm rev: 55533fcc40c99e381dc97a87c120e4757bfc4d18)
Signed-off-by: Eddie James <eajames@linux.ibm.com>
Change-Id: Ibd39949acf0694b612861f23c5ae68e7c6507504
Signed-off-by: Brad Bishop <bradleyb@fuzziesquirrel.com>
|
|
Version 1.8.4
(From meta-ibm rev: 4e261e551fcb7e63a4e029b02e73d99144c5d5bf)
Signed-off-by: Matt Spinler <spinler@us.ibm.com>
Change-Id: I32ab957bc51ccd67448ce2eda22280ad49315e5d
Signed-off-by: Brad Bishop <bradleyb@fuzziesquirrel.com>
|
|
(From meta-ibm rev: d7297da031b8e412915328cec62e013abab74344)
Change-Id: Id0eb075e8c986813f316d636565b754d2a9e140e
Signed-off-by: Alvin Wang <alvinwang@msn.com>
Signed-off-by: Brad Bishop <bradleyb@fuzziesquirrel.com>
|
|
Lei YU (2):
Add power-utils
README: Add description for psu json config
(From meta-ibm rev: 9fa69399ca7eebdf1c4eef979e308d968b842f37)
Change-Id: I5d37e3eccb9b2b6c9739cd55a01c7b7384ce1f44
Signed-off-by: Andrew Geissler <openbmcbump-github@yahoo.com>
Signed-off-by: Brad Bishop <bradleyb@fuzziesquirrel.com>
|
|
The service psu-monitor in phosphor-power now requires psu.json to
run. Otherwise it fails due to unable to open and parse the JSON file.
Install psu.json for Witherspoon so it works OK.
Tested: On Witherspoon, the psu-monitor services are started correctly,
and the PSU model, serial, etc are correct in inventory.
(From meta-ibm rev: 19034168062473250be4e8faafbd85b0d029c0d9)
Change-Id: Ia647f3d540e3ed685ab134ae42aef67e32fc5e81
Signed-off-by: Lei YU <mine260309@gmail.com>
Signed-off-by: Brad Bishop <bradleyb@fuzziesquirrel.com>
|
|
Add actions to adjust the fan floor speed table used based on the
thermal mode of the system. In addition to adjusting the fan floor speed
table, in some modes the default fan floor required adjustment as well.
These fan floor speed values and the corresponding default fan floor
speed per mode were provided by the thermal characterization team.
Tested:
Generated code from these events
(From meta-ibm rev: 0c6a7b5a5aadcbabd7bf5d25cd102fd228e26f42)
Change-Id: Ic2bfca05979cb41489fcf123f1779d2d5f089e7c
Signed-off-by: Matthew Barth <msbarth@us.ibm.com>
Signed-off-by: Brad Bishop <bradleyb@fuzziesquirrel.com>
|
|
Swift has an emmc chip, add the directive to generate a tarball for it.
(From meta-ibm rev: 42c34123c54d5ebe407fbd7b87cc5ae6c75624a5)
Change-Id: I263399cba325131be2d72d9ae2d3015050317d8f
Signed-off-by: Adriana Kobylak <anoo@us.ibm.com>
Signed-off-by: Brad Bishop <bradleyb@fuzziesquirrel.com>
|
|
Tested: Verified mboxd started on rainier with 64M option
(From meta-ibm rev: 6116cd573167826b2080b32842a50251de1896ee)
Change-Id: I6ec47d582aa87afdc1155e87213670e54174c01b
Signed-off-by: Andrew Geissler <geissonator@yahoo.com>
Signed-off-by: Brad Bishop <bradleyb@fuzziesquirrel.com>
|
|
Prevent the BMC from failing over to the other ethernet port if it
detects a network drop on the one it's using.
(From meta-ibm rev: 4c3ea265721c4a1152ae75711af68c6caa29a772)
Signed-off-by: Ben Pai <Ben_Pai@wistron.com>
Signed-off-by: Brad Bishop <bradleyb@fuzziesquirrel.com>
Change-Id: Id7f3a939e967e661937098a2ea95fdb79e973862
Signed-off-by: Brad Bishop <bradleyb@fuzziesquirrel.com>
|
|
Lei YU (2):
Move services into repo
Update MAINTAINERS
(From meta-ibm rev: 3ef4cbbfb136130da1858221f8ba4808568949cf)
Change-Id: Iecc77b4a2f2f06214d082b74d075afe8f9e9ccb7
Signed-off-by: Andrew Geissler <openbmcbump-github@yahoo.com>
Signed-off-by: Brad Bishop <bradleyb@fuzziesquirrel.com>
|
|
George Liu (1):
Update to get PSU Asset information from parsing JSON file
Lei YU (2):
Refactor: rename namespace witherspoon to phosphor
Refactor: move get pmbus access type to utility
Shawn McCarney (9):
Add Shawn McCarney as a maintainer
Initial documentation for regulator config files
Document hardware objects in regulator config file
Document operations in regulator config file
Document rule and action in regulator config file
Document I2C actions in regulator config file
Document PMBus actions in regulator config file
Document logic actions in regulator config file
Document utility actions in regulator config file
(From meta-ibm rev: b360259adc3a494162b52ab01be5601ad622d750)
Change-Id: Ic96cd6513930a6031fe6baa293ade1a9154c0e80
Signed-off-by: Andrew Geissler <openbmcbump-github@yahoo.com>
Signed-off-by: Brad Bishop <bradleyb@fuzziesquirrel.com>
|
|
1. Add dcmi config
2. Add channel config : mihawk has 2 ethernet interfaces
Tested: 1. Verify ipmitool dcmi commands work ok on mihawk
2. Ran command : ipmitool lan print
(From meta-ibm rev: 1568817763fe9edc5ef62239ab97875fa40bc5b5)
Signed-off-by: Ben Pai <Ben_Pai@wistron.com>
Change-Id: I28854535aacb6938296eda3efa1480498b899e6d
Signed-off-by: Brad Bishop <bradleyb@fuzziesquirrel.com>
|