From 12f7c29b5365fc3d40665b4326b2f2c8c559ce67 Mon Sep 17 00:00:00 2001 From: Alexander Filippov Date: Wed, 23 Sep 2020 19:03:46 +0300 Subject: meta-nicole: phosphor-hwmon: Fix VBAT gain VBAT is measured in millivolts but should be shown in volts. This commit fixes the gain parameter. (From meta-yadro rev: 8b9a6e68150bb92990314743ba7b95166cf9d409) Change-Id: I508948907b5ffc8845bf1ce04c8a811f4632171f End-User-Impact: VBAT will now show in Volts. Signed-off-by: Alexander Filippov Signed-off-by: Andrew Geissler --- .../sensors/phosphor-hwmon/obmc/hwmon/iio-hwmon-battery.conf | 2 +- 1 file changed, 1 insertion(+), 1 deletion(-) (limited to 'meta-yadro') diff --git a/meta-yadro/meta-nicole/recipes-phosphor/sensors/phosphor-hwmon/obmc/hwmon/iio-hwmon-battery.conf b/meta-yadro/meta-nicole/recipes-phosphor/sensors/phosphor-hwmon/obmc/hwmon/iio-hwmon-battery.conf index 290a72252..a6065805c 100644 --- a/meta-yadro/meta-nicole/recipes-phosphor/sensors/phosphor-hwmon/obmc/hwmon/iio-hwmon-battery.conf +++ b/meta-yadro/meta-nicole/recipes-phosphor/sensors/phosphor-hwmon/obmc/hwmon/iio-hwmon-battery.conf @@ -1,5 +1,5 @@ LABEL_in1=vbat -GAIN_in1=2.25 +GAIN_in1=0.00225 # GPIOP2 needs to be pulled high for battery voltage reading GPIOCHIP_in1=0 -- cgit v1.2.3