diff options
author | Cheng C Yang <cheng.c.yang@linux.intel.com> | 2019-07-11 20:02:14 +0300 |
---|---|---|
committer | Ed Tanous <ed.tanous@intel.com> | 2019-07-18 02:01:21 +0300 |
commit | 646438f7297cc34043cf142fc083e6bab05c7eb6 (patch) | |
tree | 2be76ba07e29db66a80540292a8170b3301b59fb | |
parent | 9a95dae4357f8150d280ef9d3d43952b7a5a49c5 (diff) | |
download | bmcweb-646438f7297cc34043cf142fc083e6bab05c7eb6.tar.xz |
Change Name of PSU Event Log
Originally PSU Event Log use PSU number as the parameter, change to PSU name
as the parameter.
Tested:
Plug out AC cable on PSU2, we can see below in Redfish Log Entries.
{
"@odata.context": "/redfish/v1/$metadata#LogEntry.LogEntry",
data.context": "/redfish/v1/$metadata#LogEntry.LogEntry",
"@odata.id": "/redfish/v1/Systems/system/LogServices/EventLog/
Entries/#1562158096",
"@odata.type": "#LogEntry.v1_4_0.LogEntry",
"Created": "2019-07-03T12:48:16+00:00",
"EntryType": "Event",
"Id": "1562158096",
"Message": "Power supply PSU2 AC power lost.",
"MessageArgs": [
"PSU2"
],
"MessageId": "OpenBMC.0.1.PowerSupplyACLost",
"Name": "System Event Log Entry",
"Severity": "Critical"
},
Signed-off-by: Cheng C Yang <cheng.c.yang@linux.intel.com>
Change-Id: I2fc32606bef334c9c5db8b8883ea14bb1e653579
-rw-r--r-- | redfish-core/include/registries/openbmc_message_registry.hpp | 14 |
1 files changed, 7 insertions, 7 deletions
diff --git a/redfish-core/include/registries/openbmc_message_registry.hpp b/redfish-core/include/registries/openbmc_message_registry.hpp index df561eddcf..f85f0257b2 100644 --- a/redfish-core/include/registries/openbmc_message_registry.hpp +++ b/redfish-core/include/registries/openbmc_message_registry.hpp @@ -994,7 +994,7 @@ const std::array registry = { .message = "Power supply %1 AC power lost.", .severity = "Critical", .numberOfArgs = 1, - .paramTypes = {"number"}, + .paramTypes = {"string"}, .resolution = "None.", }}, MessageEntry{ @@ -1004,7 +1004,7 @@ const std::array registry = { .message = "Power supply %1 configuration error.", .severity = "Critical", .numberOfArgs = 1, - .paramTypes = {"number"}, + .paramTypes = {"string"}, .resolution = "None.", }}, MessageEntry{ @@ -1015,7 +1015,7 @@ const std::array registry = { .message = "Power supply %1 fan %2 failed.", .severity = "Critical", .numberOfArgs = 2, - .paramTypes = {"number", "number"}, + .paramTypes = {"string", "string"}, .resolution = "None.", }}, MessageEntry{"PowerSupplyFailed", @@ -1024,7 +1024,7 @@ const std::array registry = { .message = "Power supply %1 failed.", .severity = "Critical", .numberOfArgs = 1, - .paramTypes = {"number"}, + .paramTypes = {"string"}, .resolution = "None.", }}, MessageEntry{"PowerSupplyFailurePredicted", @@ -1034,7 +1034,7 @@ const std::array registry = { .message = "Power supply %1 failure predicted.", .severity = "Warning", .numberOfArgs = 1, - .paramTypes = {"number"}, + .paramTypes = {"string"}, .resolution = "None.", }}, MessageEntry{ @@ -1044,7 +1044,7 @@ const std::array registry = { .message = "Power supply %1 inserted.", .severity = "OK", .numberOfArgs = 1, - .paramTypes = {"number"}, + .paramTypes = {"string"}, .resolution = "None.", }}, MessageEntry{ @@ -1054,7 +1054,7 @@ const std::array registry = { .message = "Power supply %1 removed.", .severity = "Warning", .numberOfArgs = 1, - .paramTypes = {"number"}, + .paramTypes = {"string"}, .resolution = "None.", }}, MessageEntry{ |