-rw-r--r--meta-ibm/meta-witherspoon/recipes-phosphor/fans/phosphor-fan-control-events-config-native/events.yaml2
-rw-r--r--meta-ibm/meta-witherspoon/recipes-phosphor/fans/phosphor-fan-control-zone-config-native/zones.yaml41
2 files changed, 42 insertions, 1 deletions
diff --git a/meta-ibm/meta-witherspoon/recipes-phosphor/fans/phosphor-fan-control-events-config-native/events.yaml b/meta-ibm/meta-witherspoon/recipes-phosphor/fans/phosphor-fan-control-events-config-native/events.yaml
index e726f90f22..5f6a094bac 100644
--- a/meta-ibm/meta-witherspoon/recipes-phosphor/fans/phosphor-fan-control-events-config-native/events.yaml
+++ b/meta-ibm/meta-witherspoon/recipes-phosphor/fans/phosphor-fan-control-events-config-native/events.yaml
@@ -455,7 +455,7 @@ events:
actions:
- name: use_alternate_events_on_state
property:
- value: Custom
+ value: CUSTOM
type: std::string
defevents:
- name: default_floor_boundary
diff --git a/meta-ibm/meta-witherspoon/recipes-phosphor/fans/phosphor-fan-control-zone-config-native/zones.yaml b/meta-ibm/meta-witherspoon/recipes-phosphor/fans/phosphor-fan-control-zone-config-native/zones.yaml
index 29dd2c79e7..d31b304450 100644
--- a/meta-ibm/meta-witherspoon/recipes-phosphor/fans/phosphor-fan-control-zone-config-native/zones.yaml
+++ b/meta-ibm/meta-witherspoon/recipes-phosphor/fans/phosphor-fan-control-zone-config-native/zones.yaml
@@ -16,6 +16,30 @@ zone_configuration:
default_floor: 8000
increase_delay: 5
decrease_interval: 30
+ interfaces:
+ - name: xyz.openbmc_project.Control.ThermalMode
+ properties:
+ - name: Supported
+ type: array[string]
+ values:
+ - value: DEFAULT
+ description: >
+ Default thermal control mode
+ - value: CUSTOM
+ description: >
+ Custom thermal control mode for handling the use of
+ optical cables located behind the GPU exhaust that
+ could produce overtemp warnings without this mode
+ enabled.
+ - name: Current
+ type: string
+ persist: true
+ values:
+ - value: DEFAULT
+ description: >
+ Set current thermal control mode to the
+ default which will be replaced on startup if
+ another selected mode was persisted.
#Water cooled zones
- zone_conditions:
@@ -30,3 +54,20 @@ zone_configuration:
default_floor: 8000
increase_delay: 5
decrease_interval: 30
+ interfaces:
+ - name: xyz.openbmc_project.Control.ThermalMode
+ properties:
+ - name: Supported
+ type: array[string]
+ values:
+ - value: DEFAULT
+ description: >
+ Default thermal control mode
+ - name: Current
+ type: string
+ persist: true
+ values:
+ - value: DEFAULT
+ description: >
+ Set current thermal control mode to the
+ default. No other modes are supported.