2023-05-12Revert "Add socket-id for the first console"Andrew Jeffery1-1/+0
This reverts commit ec7cab9378f548e94ee4af83946b2583d1fc7194. ec7cab9378f5 ("Add socket-id for the first console") was only a partial fixup of the obmc-console configurations found in the tree. For historical reasons not all platforms that support multiple consoles install a client configuration file for all consoles. Instead they relied on some default behaviour that was removed in obmc-console's 4e7186918599 ("Fixed broken dbus interface for multiple consoles"). Applying the configuration changes in the manner of ec7cab9378f5 ("Add socket-id for the first console") resulted in an asymmetric configuration between the client and server, breaking some SSH SOL instances. As of ae2460d0b8e8 ("obmc-console: Provide a default value for `console-id`.") in obmc-console the requirement to specify `socket-id`[^1] is lifted. Instead, the configuration can choose to override a default value. This restores the original behaviour and unbreaks SSH SOL. [^1]: Now an alias of the `console-id` configuration key Websocket and IPMI consoles remain broken. A fix is under development that also takes a proper approach to supporting multiple consoles in bmcweb, and the same solution pattern can be applied in ipmid. More discussion of the problems involved can be found here: https://amboar.github.io/notes/2023/05/08/happenings-in-obmc-console.html Change-Id: I274284c791758f336da6d6301dc523bac2b5dd69 Signed-off-by: Andrew Jeffery <andrew@aj.id.au>
2023-04-21Add socket-id for the first consoleNinad Palsule1-0/+1
This drop adds socket-id for first console. This was left out before but with the new design this parameter is required and enforced by obmc-console code. It is decided to set "socket-id = console0" initially because that is the current path used by bmcweb but in future you can change this value to whatever is appropriate. The console information is now available through the DBUS interface. Each console server register it's object path on DBUS. The leaf node of the object path is used to create a console path. For example in the following console0 the leaf node "console0" is used to make up the console path and the GUI will use console path "/console/console0" to connect to the console. busctl tree xyz.openbmc_project.Console.console0 `-/xyz `-/xyz/openbmc_project `-/xyz/openbmc_project/console `-/xyz/openbmc_project/console/console0 Here is a discord thread where new design was discussed. https://discord.com/channels/775381525260664832/1083551792094249051 Tested: Tested on the rainier system. Related commits: 1) phosphor-dbus-interface: https://gerrit.openbmc.org/c/openbmc/phosphor-dbus-interfaces/+/61486 2) obmc-console: https://gerrit.openbmc.org/c/openbmc/obmc-console/+/62496 3) bmcweb: https://gerrit.openbmc.org/c/openbmc/bmcweb/+/62525 Change-Id: I5fd06f3aac69872a3e5032d592a9b59711795cfe Signed-off-by: Ninad Palsule <ninadpalsule@us.ibm.com>
2022-05-19meta-yadro: vegman: setup obmc-consoleAndrei Kartashev1-0/+3
Add obmc-console configuration for Yadro VEGMAN machines Signed-off-by: Andrei Kartashev <a.kartashev@yadro.com> Change-Id: I392a6621f1588833d3aaf6187bc277ea661d416f