From e161514219e0dc8a957dabbb8529fb9fcac4e115 Mon Sep 17 00:00:00 2001 From: Brad Bishop Date: Wed, 22 Apr 2020 14:06:02 -0400 Subject: meta-ibm: move all meta-witherspoon metadata The metadata common to all IBM systems is confusingly split between meta-ibm and meta-witherspoon. Move everything to meta-ibm. The meta-ibm README is re-written to more accurately reflect the scope of the layer. Allow the configuration samples (bblayers.conf.sample, local.conf.sample) to be sourced from either meta-ibm or meta-witherspoon until such a time that any workflows and tooling have had the opportunity to move to meta-ibm. (From meta-ibm rev: 6e05ef2e90b214eaf4e43ee7027bbbb1d8d09442) Change-Id: I3ec890d5300f9649c974ea6b9dca93a2e8a889ab Signed-off-by: Brad Bishop Signed-off-by: Andrew Geissler --- .../swift/zones.yaml | 68 ++++++++++++++++++++++ 1 file changed, 68 insertions(+) create mode 100644 meta-ibm/recipes-phosphor/fans/phosphor-fan-control-zone-config/swift/zones.yaml (limited to 'meta-ibm/recipes-phosphor/fans/phosphor-fan-control-zone-config/swift/zones.yaml') diff --git a/meta-ibm/recipes-phosphor/fans/phosphor-fan-control-zone-config/swift/zones.yaml b/meta-ibm/recipes-phosphor/fans/phosphor-fan-control-zone-config/swift/zones.yaml new file mode 100644 index 0000000000..c10c6c1860 --- /dev/null +++ b/meta-ibm/recipes-phosphor/fans/phosphor-fan-control-zone-config/swift/zones.yaml @@ -0,0 +1,68 @@ +manager_configuration: + power_on_delay: 20 + +zone_configuration: + +#Air cooled zones +- zone_conditions: + - name: air_cooled_chassis + + zones: + - zone: 0 + cooling_profiles: + - air + - all + full_speed: 9500 + default_floor: 8000 + increase_delay: 5 + decrease_interval: 30 + interfaces: + - name: xyz.openbmc_project.Control.ThermalMode + properties: + - name: Supported + type: array[string] + values: + - value: DEFAULT + description: > + Default thermal control mode + - name: Current + type: string + persist: true + values: + - value: DEFAULT + description: > + Set current thermal control mode to the + default which will be replaced on startup if + another supported mode was selected & persisted. + +#Water cooled zones +- zone_conditions: + - name: water_and_air_cooled_chassis + + zones: + - zone: 0 + cooling_profiles: + - water + - all + full_speed: 9500 + default_floor: 8000 + increase_delay: 5 + decrease_interval: 30 + interfaces: + - name: xyz.openbmc_project.Control.ThermalMode + properties: + - name: Supported + type: array[string] + values: + - value: DEFAULT + description: > + Default thermal control mode + - name: Current + type: string + persist: true + values: + - value: DEFAULT + description: > + Set current thermal control mode to the + default which will be replaced on startup if + another supported mode was selected & persisted. -- cgit v1.2.3