Age | Commit message (Collapse) | Author | Files | Lines |
|
Before the patch, the diagnostic mode was displayed as "Not available",
after the patch "Diagnostic mode".
Test: in the console run the command
"busctl set-property xyz.openbmc_project.State.Host \
/xyz/openbmc_project/state/host0 \
xyz.openbmc_project.State.Host CurrentHostState \
s "xyz.openbmc_project.State.Host.HostState.DiagnosticMode".
open the "Server power operations" page,
check the Server status
Signed-off-by: glukhov.mikhail <mikl@greenfil.ru>
Change-Id: I90d04e05188eb92c4c4b38fe578ae36db0424b5c
|
|
In the boot page, it did not allowed to send the same options.
However, there is a case that it is needed to send the boot options
anyway.
In typical x86 systems, when the BIOS is rebooted, it will clear the
boot options during the boot, so the settings in the web page does not
reflect to the BMC's boot option settings.
This patch allows to send the options anyway, so as long as user
"applies" the settings, the boot options are set to BMC.
Tested:
Verify the same boot options settings are set to BMC after BIOS
boots.
Signed-off-by: Lei YU <yulei.sh@bytedance.com>
Change-Id: I18ce341bbf9d968a78e8d818b005d1774936a48b
|
|
This is the third update to the information architecture changes and
has the following changes:
- The control section has been updated to operations
- The server led page has been removed
- The firmware page is moved to operations section
Signed-off-by: Sandeepa Singh <sandeepa.singh@ibm.com>
Change-Id: I2e23da447890d7bee51892e1f782d5f2db6dded4
|