summaryrefslogtreecommitdiff
path: root/drivers
diff options
context:
space:
mode:
authorVasileios Amoiridis <vassilisamir@gmail.com>2024-06-07 00:22:53 +0300
committerGreg Kroah-Hartman <gregkh@linuxfoundation.org>2024-07-05 10:00:33 +0300
commit272736d778a42a3cdb623d53665a0e6a85125b66 (patch)
tree09c5cc44078a4e86a3b14ade280d043b5a1dec1d /drivers
parent75a024d3ab0d331fc1d0b640b00e63d31d556b1e (diff)
downloadlinux-272736d778a42a3cdb623d53665a0e6a85125b66.tar.xz
iio: chemical: bme680: Fix pressure value output
commit ae1f7b93b52095be6776d0f34957b4f35dda44d9 upstream. The IIO standard units are measured in kPa while the driver is using hPa. Apart from checking the userspace value itself, it is mentioned also in the Bosch API [1] that the pressure value is in Pascal. [1]: https://github.com/boschsensortec/BME68x_SensorAPI/blob/v4.4.8/bme68x_defs.h#L742 Fixes: 1b3bd8592780 ("iio: chemical: Add support for Bosch BME680 sensor") Signed-off-by: Vasileios Amoiridis <vassilisamir@gmail.com> Link: https://lore.kernel.org/r/20240606212313.207550-2-vassilisamir@gmail.com Cc: <Stable@vger.kernel.org> Signed-off-by: Jonathan Cameron <Jonathan.Cameron@huawei.com> Signed-off-by: Greg Kroah-Hartman <gregkh@linuxfoundation.org>
Diffstat (limited to 'drivers')
-rw-r--r--drivers/iio/chemical/bme680_core.c2
1 files changed, 1 insertions, 1 deletions
diff --git a/drivers/iio/chemical/bme680_core.c b/drivers/iio/chemical/bme680_core.c
index b2db59812755..9e2e9f137b79 100644
--- a/drivers/iio/chemical/bme680_core.c
+++ b/drivers/iio/chemical/bme680_core.c
@@ -678,7 +678,7 @@ static int bme680_read_press(struct bme680_data *data,
}
*val = bme680_compensate_press(data, adc_press);
- *val2 = 100;
+ *val2 = 1000;
return IIO_VAL_FRACTIONAL;
}