Age | Commit message (Collapse) | Author | Files | Lines |
|
In hclgevf_mbx_handler() and hclgevf_get_mbx_resp() functions,
there is a typical store-store and load-load scenario between
received_resp and additional_info. This patch adds barrier
to fix the problem.
Fixes: 4671042f1ef0 ("net: hns3: add match_id to check mailbox response from PF to VF")
Signed-off-by: Yonglong Liu <liuyonglong@huawei.com>
Signed-off-by: Jijie Shao <shaojijie@huawei.com>
Signed-off-by: David S. Miller <davem@davemloft.net>
|
|
Currently, hns3 mailbox processing between PF and VF missed to convert
message byte order and use data type u16 instead of __le16 for mailbox
data process. These processes may cause problems between different
architectures.
So this patch uses __le16/__le32 data type to define mailbox data
structures. To be compatible with old hns3 driver, these structures use
one-byte alignment. Then byte order conversions are added to mailbox
messages from PF to VF.
Signed-off-by: Jie Wang <wangjie125@huawei.com>
Signed-off-by: Guangbin Huang <huangguangbin2@huawei.com>
Signed-off-by: David S. Miller <davem@davemloft.net>
|
|
This patch fixes wrong words in comments.
Signed-off-by: Peng Li<lipeng321@huawei.com>
Signed-off-by: Guangbin Huang <huangguangbin2@huawei.com>
Signed-off-by: David S. Miller <davem@davemloft.net>
|
|
The param of function hclgevf_get_mbx_resp has been changed but the
comments not upodated. This patch updates it.
Signed-off-by: Peng Li<lipeng321@huawei.com>
Signed-off-by: Guangbin Huang <huangguangbin2@huawei.com>
Signed-off-by: David S. Miller <davem@davemloft.net>
|
|
This patch uses common cmdq init and uninit APIs to replace the old APIs in
VF cmdq module init and uninit module. Then the old VF init and uninit
APIs is deleted.
Signed-off-by: Jie Wang <wangjie125@huawei.com>
Signed-off-by: Guangbin Huang <huangguangbin2@huawei.com>
Signed-off-by: David S. Miller <davem@davemloft.net>
|
|
This patch firstly uses new hardware description struct hclge_comm_hw as
child member of hclgevf_hw and deletes the old hardware description child
members. All the hclgevf_hw variables used in VF module is modified
according to the new hclgevf_hw.
Secondly hclgevf_cmd_send is refactored to use hclge_comm_cmd_send APIs.
The old functions called by hclgevf_cmd_send are all deleted. Still we kept
hclgevf_cmd_send to avoid too many meaningless modifications.
Signed-off-by: Jie Wang <wangjie125@huawei.com>
Signed-off-by: Guangbin Huang <huangguangbin2@huawei.com>
Signed-off-by: David S. Miller <davem@davemloft.net>
|
|
This patch use new common struct hclge_desc to replace struct hclgevf_desc
in VF cmdq module and then delete the old struct hclgevf_desc.
Signed-off-by: Jie Wang <wangjie125@huawei.com>
Signed-off-by: Guangbin Huang <huangguangbin2@huawei.com>
Signed-off-by: David S. Miller <davem@davemloft.net>
|
|
Currently, the hns3_remove function firstly uninstall client instance,
and then uninstall acceletion engine device. The netdevice is freed in
client instance uninstall process, but acceletion engine device uninstall
process still use it to trace runtime information. This causes a use after
free problem.
So fixes it by check the instance register state to avoid use after free.
Fixes: d8355240cf8f ("net: hns3: add trace event support for PF/VF mailbox")
Signed-off-by: Jie Wang <wangjie125@huawei.com>
Signed-off-by: Guangbin Huang <huangguangbin2@huawei.com>
Signed-off-by: David S. Miller <davem@davemloft.net>
|
|
This patch packages two new function to simplify the function
hclgevf_mbx_handler, and it can reduce the code cycle complexity
and make code more concise.
Signed-off-by: Peng Li <lipeng321@huawei.com>
Signed-off-by: Guangbin Huang <huangguangbin2@huawei.com>
Signed-off-by: David S. Miller <davem@davemloft.net>
|
|
The param msg_q is redundant, copy &req->msg to
hdev->arq.msg_q[hdev->arq.tail] directly makes code clean.
So removes the redundant param msg_q.
Signed-off-by: Peng Li <lipeng321@huawei.com>
Signed-off-by: Guangbin Huang <huangguangbin2@huawei.com>
Signed-off-by: David S. Miller <davem@davemloft.net>
|
|
Use memcpy to copy req->msg.resp_data to resp->additional_info,
to simplify the code and improve a little efficiency.
Signed-off-by: Peng Li <lipeng321@huawei.com>
Signed-off-by: Guangbin Huang <huangguangbin2@huawei.com>
Signed-off-by: David S. Miller <davem@davemloft.net>
|
|
This patch removes the redundant param mbx_event_pending.
Signed-off-by: Peng Li <lipeng321@huawei.com>
Signed-off-by: Guangbin Huang <huangguangbin2@huawei.com>
Signed-off-by: David S. Miller <davem@davemloft.net>
|
|
In bond 4, when the link goes down and up repeatedly, the bond may get an
unknown speed, and then this port can not work.
The driver notify netif_carrier_on() before update the link state, when the
bond receive carrier on, will query the speed of the port, if the query
operation happens before updating the link state, will get an unknown
speed. So need to notify netif_carrier_on() after update the link state.
Fixes: 46a3df9f9718 ("net: hns3: Add HNS3 Acceleration Engine & Compatibility Layer Support")
Fixes: e2cb1dec9779 ("net: hns3: Add HNS3 VF HCL(Hardware Compatibility Layer) Support")
Signed-off-by: Yonglong Liu <liuyonglong@huawei.com>
Signed-off-by: Guangbin Huang <huangguangbin2@huawei.com>
Signed-off-by: Jakub Kicinski <kuba@kernel.org>
|
|
When VF need response from PF, VF will wait (1us - 1s) to receive
the response, or it will wait timeout and the VF action fails.
If VF do not receive response in 1st action because timeout,
the 2nd action may receive response for the 1st action, and get
incorrect response data.VF must reciveve the right response from
PF,or it will cause unexpected error.
This patch adds match_id to check mailbox response from PF to VF,
to make sure VF get the right response:
1. The message sent from VF was labelled with match_id which was a
unique 16-bit non-zero value.
2. The response sent from PF will label with match_id which got from
the request.
3. The VF uses the match_id to match request and response message.
This scheme depends on PF driver supports match_id, if PF driver doesn't
support then VF will uses the original scheme.
Signed-off-by: Peng Li <lipeng321@huawei.com>
Signed-off-by: Guangbin Huang <huangguangbin2@huawei.com>
Signed-off-by: Jakub Kicinski <kuba@kernel.org>
|
|
To reduce the processing of unnecessary mailbox command when PF supports
actively push its link status to VFs, VFs stop sending request link
status command in periodic service task in this case.
Signed-off-by: Guangbin Huang <huangguangbin2@huawei.com>
Signed-off-by: Huazhong Tan <tanhuazhong@huawei.com>
Signed-off-by: David S. Miller <davem@davemloft.net>
|
|
This patch adds trace event support for PF/VF mailbox.
Signed-off-by: Yufeng Mo <moyufeng@huawei.com>
Signed-off-by: Huazhong Tan <tanhuazhong@huawei.com>
Signed-off-by: David S. Miller <davem@davemloft.net>
|
|
Currently, PF responds to VF depending on what mailbox it is
handling, it is a bit inflexible. The correct way is, PF should
check the mbx_need_resp field to decide whether gives response
to VF.
Signed-off-by: Huazhong Tan <tanhuazhong@huawei.com>
Signed-off-by: Yufeng Mo <moyufeng@huawei.com>
Signed-off-by: David S. Miller <davem@davemloft.net>
|
|
For making the code more readable, this adds several new
structure to replace the msg field in structure
hclge_mbx_vf_to_pf_cmd and hclge_mbx_pf_to_vf_cmd.
Also uses macro to instead of some magic number.
Signed-off-by: Yufeng Mo <moyufeng@huawei.com>
Signed-off-by: Huazhong Tan <tanhuazhong@huawei.com>
Signed-off-by: David S. Miller <davem@davemloft.net>
|
|
Currently, when mailbox handling fails, the PF driver
just responds 1 to the VF driver. It is not sufficient
for the VF driver to find out why its mailbox fails.
So the error should be responded to VF, but the error
is type int and the response field in struct
hclge_mbx_pf_to_vf_cmd is type u16, a conversion is
needed.
Signed-off-by: Jian Shen <shenjian15@huawei.com>
Signed-off-by: Huazhong Tan <tanhuazhong@huawei.com>
Signed-off-by: David S. Miller <davem@davemloft.net>
|
|
Using '%d' for printing type unsigned int or '%u' for
type int would cause static tools to give false warnings,
so this patch cleanups this warning by using the suitable
format specifier of the type of variable.
BTW, modifies the type of some variables and macro to
synchronize with their usage.
Signed-off-by: Guojia Liao <liaoguojia@huawei.com>
Signed-off-by: Huazhong Tan <tanhuazhong@huawei.com>
Signed-off-by: David S. Miller <davem@davemloft.net>
|
|
This patch adds supports for setting VF trust by host. If specified
VF is trusted, then it can enable promisc(include allmulti mode).
If a trusted VF enabled promisc, and being untrusted, host will
disable promisc mode for this VF.
For VF will update its promisc mode from set_rx_mode now, so it's
unnecessary to set broadcst promisc mode when initialization or
reset.
Signed-off-by: Jian Shen <shenjian15@huawei.com>
Signed-off-by: Huazhong Tan <tanhuazhong@huawei.com>
Signed-off-by: Jakub Kicinski <jakub.kicinski@netronome.com>
|
|
This patch fixes some incorrect type in assignment reported by sparse.
Those sparse warning as below:
- warning : restricted __le16 degrades to integer
- warning : cast from restricted __le32
- warning : expected restricted __le32
- warning : cast from restricted __be32
- warning : cast from restricted __be16
- warning : cast to restricted __le16
Signed-off-by: Guojia Liao <liaoguojia@huawei.com>
Reviewed-by: Peng Li <lipeng321@huawei.com>
Signed-off-by: Huazhong Tan <tanhuazhong@huawei.com>
Signed-off-by: David S. Miller <davem@davemloft.net>
|
|
All constant in 'enum HCLGE_MBX_OPCODE' start with HCLGE, except
'HLCGE_MBX_PUSH_VLAN_INFO' (C and L switched)
s/HLC/HCL/
Signed-off-by: Christophe JAILLET <christophe.jaillet@wanadoo.fr>
Signed-off-by: David S. Miller <davem@davemloft.net>
|
|
The value of msg_data may be NULL in some cases, which will cause
errors reported by some compiler.
So this patch adds a check to fix it.
Signed-off-by: Weihang Li <liweihang@hisilicon.com>
Signed-off-by: Peng Li <lipeng321@huawei.com>
Signed-off-by: Huazhong Tan <tanhuazhong@huawei.com>
Signed-off-by: David S. Miller <davem@davemloft.net>
|
|
This patch uses a reserved byte in the hclge_mbx_vf_to_pf_cmd
to save the need_resp flag, so when PF received the mailbox,
it can use it to decise whether send a response to VF.
For hclge_set_vf_uc_mac_addr(), it should use mbx_need_resp flag
to decide whether send response to VF.
Signed-off-by: Huazhong Tan <tanhuazhong@huawei.com>
Signed-off-by: Peng Li <lipeng321@huawei.com>
Signed-off-by: David S. Miller <davem@davemloft.net>
|
|
Since irq handler and mailbox task will both update arq's count,
so arq's count should use atomic_t instead of u32, otherwise
its value may go wrong finally.
Fixes: 07a0556a3a73 ("net: hns3: Changes to support ARQ(Asynchronous Receive Queue)")
Signed-off-by: Huazhong Tan <tanhuazhong@huawei.com>
Signed-off-by: Peng Li <lipeng321@huawei.com>
Signed-off-by: David S. Miller <davem@davemloft.net>
|
|
When wait for response timeout or response code not match, there
should be more information for debugging.
Signed-off-by: Huazhong Tan <tanhuazhong@huawei.com>
Signed-off-by: Peng Li <lipeng321@huawei.com>
Signed-off-by: David S. Miller <davem@davemloft.net>
|
|
In original codes, ndo_set_vf_vlan() in hns3 driver was implemented
wrong. It adds or removes VLAN into VLAN filter for VF, but VF is
unaware of it.
This patch fixes it. When VF loads up, it firstly queries the port
based VLAN state from PF. When user change port based VLAN state
from PF, PF firstly checks whether the VF is alive. If the VF is
alive, then PF notifies the VF the modification; otherwise PF
configure the port based VLAN state directly.
Fixes: 46a3df9f9718 ("net: hns3: Add HNS3 Acceleration Engine & Compatibility Layer Support")
Signed-off-by: Jian Shen <shenjian15@huawei.com>
Signed-off-by: Huazhong Tan <tanhuazhong@huawei.com>
Signed-off-by: David S. Miller <davem@davemloft.net>
|
|
Method for obtaining the media type of the VF network port periodically,
regular tasks will not run until the network port UP. When the network
port is DOWN, the network port cannot obtain the media type.
Modifies the media type obtained when initializing the VF network port.
Signed-off-by: liuzhongzhu <liuzhongzhu@huawei.com>
Signed-off-by: Peng Li <lipeng321@huawei.com>
Signed-off-by: Huazhong Tan <tanhuazhong@huawei.com>
Signed-off-by: David S. Miller <davem@davemloft.net>
|
|
Run ethtool ethx when displaying device information in VF,
the supported port and link mode items will be empty.
This patch fixes it.
Fixes: e2cb1dec9779 ("net: hns3: Add HNS3 VF HCL(Hardware Compatibility Layer) Support")
Signed-off-by: liuzhongzhu <liuzhongzhu@huawei.com>
Signed-off-by: Peng Li <lipeng321@huawei.com>
Signed-off-by: Huazhong Tan <tanhuazhong@huawei.com>
Signed-off-by: David S. Miller <davem@davemloft.net>
|
|
udelay() in driver may always occupancy processor. If there is only
one cpu in system, the VF driver may initialize fail when insmod
PF and VF driver in the same system. This patch use msleep() to free
cpu when VF wait PF message.
Signed-off-by: Peng Li <lipeng321@huawei.com>
Signed-off-by: David S. Miller <davem@davemloft.net>
|
|
According to hardware's description, after the reset occurs, the driver
needs to re-initialize the command queue before sending and receiving
any commands. Therefore, the VF's driver needs to identify the command
queue needs to re-initialize with HCLGEVF_STATE_CMD_DISABLE, and does
not allow sending or receiving commands before the re-initialization.
Signed-off-by: Huazhong Tan <tanhuazhong@huawei.com>
Signed-off-by: David S. Miller <davem@davemloft.net>
|
|
When PF performs a function reset, the hardware will reset both PF
and all the VF belong to this PF. Hence, both PF's driver and VF's
driver need to perform corresponding reset operations.
Before PF driver asserting function reset to hardware, it firstly
set up VF's hardware reset status, and inform the VF driver with
HNAE3_VF_PF_FUNC_RESET, then VF driver sets this reset type to
reset_pending and shechule reset task to stop IO and waits for the
hardware reset status to clear. When PF driver has reinitialized the
hardware and is ready to process mailbox from VF, PF driver clears
VF's hardware reset status for VF to continue its reset process.
Also, this patch uses readl_poll_timeout to simplify the hardware reset
status waitting.
Signed-off-by: Huazhong Tan <tanhuazhong@huawei.com>
Signed-off-by: Yunsheng Lin <linyunsheng@huawei.com>
Signed-off-by: David S. Miller <davem@davemloft.net>
|
|
Currently when VF need to reset itself, it will send a cmd to PF,
after receiving the VF reset requset, PF sends a cmd to inform
VF to enter the reset process and send a cmd to firmware to do the
actual reset for the VF, it is possible that firmware has resetted
the VF, but VF has not entered the reset process, which may cause
IO not stopped problem when firmware is resetting VF.
This patch fixes it by adjusting the VF reset process, when VF
need to reset itself, it will enter the reset process first, and
it will tell the PF to send cmd to firmware to reset itself.
Add member reset_pending to struct hclgevf_dev, which indicates that
there is reset event need to be processed by the VF's reset task, and
the VF's reset task chooses the highest-level one and clears other
low-level one when it processes reset_pending.
hclge_inform_reset_assert_to_vf function is unused now, but it will
be used to support the PF reset with VF working, so declare it in
the header file.
Signed-off-by: Huazhong Tan <tanhuazhong@huawei.com>
Signed-off-by: Yunsheng Lin <linyunsheng@huawei.com>
Signed-off-by: David S. Miller <davem@davemloft.net>
|
|
hclge_dev/hclgevf_dev
Saving reset related information in the hclge_dev/hclgevf_dev
structure is more suitable than the hnae3_handle, since hardware
related information is kept in these two structure.
Signed-off-by: Huazhong Tan <tanhuazhong@huawei.com>
Signed-off-by: David S. Miller <davem@davemloft.net>
|
|
The payload of mailbox message is 16 byte and the value of
HCLGE_MBX_MAX_ARQ_MSG_SIZE is 8. A message truncated problem will
happen when mailbox message is converted to ARQ message. This patch
replaces HCLGE_MBX_MAX_ARQ_MSG_SIZE with the size of ARQ message in
hclgevf_mbx_handler to fix this problem.
Fixes: b11a0bb231f3 ("net: hns3: Add mailbox support to VF driver")
Signed-off-by: Fuyun Liang <liangfuyun1@huawei.com>
Signed-off-by: Peng Li <lipeng321@huawei.com>
Signed-off-by: Salil Mehta <salil.mehta@huawei.com>
Signed-off-by: David S. Miller <davem@davemloft.net>
|
|
For consistency, prefix hnae_ should be modified to hnae3_.
Signed-off-by: Peng Li <lipeng321@huawei.com>
Signed-off-by: Huazhong Tan <tanhuazhong@huawei.com>
Signed-off-by: David S. Miller <davem@davemloft.net>
|
|
Before the firmware updates the crq's tail pointer, if the VF driver
reads the data in the crq, the data may be incomplete at this time,
which will lead to the driver read an unknown message.
This patch fixes it by checking if crq is empty before reading the
message.
Fixes: b11a0bb231f3 ("net: hns3: Add mailbox support to VF driver")
Signed-off-by: Xi Wang <wangxi11@huawei.com>
Signed-off-by: Peng Li <lipeng321@huawei.com>
Signed-off-by: Salil Mehta <salil.mehta@huawei.com>
Signed-off-by: David S. Miller <davem@davemloft.net>
|
|
Reset Asserting message is forwarded by PF to inform VF about
the hardware reset which is about to happen. This might be due
to the earlier VF reset request received by the PF or because PF
for any reason decides to undergo reset. This message results in
VF to go in pending state in which it polls the hardware to
complete the reset and then further resets/tears its own stack.
Signed-off-by: Salil Mehta <salil.mehta@huawei.com>
Signed-off-by: David S. Miller <davem@davemloft.net>
|
|
Current mailbox CRQ could consists of both synchronous and async
responses from the PF. Synchronous responses are time critical
and should be handed over to the waiting tasks/context as quickly
as possible otherwise timeout occurs.
Above problem gets accentuated if CRQ consists of even single
async message. Hence, it is important to have quick handling of
synchronous messages and maybe deferred handling of async messages
This patch introduces separate ARQ(async receive queues) for the
async messages. These messages are processed later with repsect
to mailbox task while synchronous messages still gets processed
in context to mailbox interrupt.
ARQ is important as VF reset introduces some new async messages
like MBX_ASSERTING_RESET which adds up to the presssure on the
responses for synchronousmessages and they timeout even more
quickly.
Signed-off-by: Salil Mehta <salil.mehta@huawei.com>
Signed-off-by: David S. Miller <davem@davemloft.net>
|
|
This patch adds support for querying speed and duplex by ethtool ethX
to VF.
Signed-off-by: Fuyun Liang <liangfuyun1@huawei.com>
Signed-off-by: Peng Li <lipeng321@huawei.com>
Signed-off-by: David S. Miller <davem@davemloft.net>
|
|
VF changes unicast mac address by sending mailbox msg to PF, then PF
completes the mac address modification. It may fail when the target
uc mac address is already in the mac_vlan table. VF should be aware
of it by reading the message result.
Signed-off-by: Jian Shen <shenjian15@huawei.com>
Signed-off-by: Peng Li <lipeng321@huawei.com>
Signed-off-by: David S. Miller <davem@davemloft.net>
|
|
Driver check the out_vld bit when get a new cmdq BD, if the bit is 1,
the BD is valid. driver Should set the bit 0 after used and hw will
set the bit 1 if get a valid BD.
Signed-off-by: Peng Li <lipeng321@huawei.com>
Signed-off-by: David S. Miller <davem@davemloft.net>
|
|
This patch adds the support of the mailbox to the VF driver. The
mailbox shall be used as an interface to communicate with the
PF driver for various purposes like {set|get} MAC related
operations, reset, link status etc. The mailbox supports both
synchronous and asynchronous command send to PF driver.
Signed-off-by: Salil Mehta <salil.mehta@huawei.com>
Signed-off-by: lipeng <lipeng321@huawei.com>
Signed-off-by: David S. Miller <davem@davemloft.net>
|