Arm TrustZone CryptoCell cryptographic accelerators Required properties: - compatible: must be "arm,cryptocell-712-ree". - reg: shall contain base register location and length. Typically length is 0x10000. - interrupts: shall contain the interrupt for the device. Optional properties: - interrupt-parent: can designate the interrupt controller the device interrupt is connected to, if needed. - clocks: may contain the clock handling the device, if needed. - power-domains: may contain a reference to the PM domain, if applicable. Examples: Zynq FPGA device ---------------- arm_cc7x: arm_cc7x@80000000 { compatible = "arm,cryptocell-712-ree"; interrupt-parent = <&intc>; interrupts = < 0 30 4 >; reg = < 0x80000000 0x10000 >; };