authorHans de Goede <hdegoede@redhat.com>2022-05-06 12:50:40 +0300
committerJonathan Cameron <Jonathan.Cameron@huawei.com>2022-05-07 17:23:39 +0300
commit048058399f19d43cf21de9f5d36cd8144337d004 (patch)
tree5b692b880cdb09fc117b4b7e24373e2e116f194c
parentfe18894930a025617114aa8ca0adbf94d5bffe89 (diff)
downloadlinux-048058399f19d43cf21de9f5d36cd8144337d004.tar.xz
iio: adc: axp288: Override TS pin bias current for some models
Since commit 9bcf15f75cac ("iio: adc: axp288: Fix TS-pin handling") we preserve the bias current set by the firmware at boot. This fixes issues we were seeing on various models. Some models like the Nuvision Solo 10 Draw tablet actually need the old hardcoded 80ųA bias current for battery temperature monitoring to work properly. Add a quirk entry for the Nuvision Solo 10 Draw to the DMI quirk table to restore setting the bias current to 80ųA on this model. Fixes: 9bcf15f75cac ("iio: adc: axp288: Fix TS-pin handling") BugLink: https://bugzilla.kernel.org/show_bug.cgi?id=215882 Signed-off-by: Hans de Goede <hdegoede@redhat.com> Link: https://lore.kernel.org/r/20220506095040.21008-1-hdegoede@redhat.com Cc: <Stable@vger.kernel.org> Signed-off-by: Jonathan Cameron <Jonathan.Cameron@huawei.com>
-rw-r--r--drivers/iio/adc/axp288_adc.c8
1 files changed, 8 insertions, 0 deletions
diff --git a/drivers/iio/adc/axp288_adc.c b/drivers/iio/adc/axp288_adc.c
index a4b8be5b8f88..580361bd9849 100644
--- a/drivers/iio/adc/axp288_adc.c
+++ b/drivers/iio/adc/axp288_adc.c
@@ -196,6 +196,14 @@ static const struct dmi_system_id axp288_adc_ts_bias_override[] = {
},
.driver_data = (void *)(uintptr_t)AXP288_ADC_TS_BIAS_80UA,
},
+ {
+ /* Nuvision Solo 10 Draw */
+ .matches = {
+ DMI_MATCH(DMI_SYS_VENDOR, "TMAX"),
+ DMI_MATCH(DMI_PRODUCT_NAME, "TM101W610L"),
+ },
+ .driver_data = (void *)(uintptr_t)AXP288_ADC_TS_BIAS_80UA,
+ },
{}
};