authorDave Jiang <dave.jiang@intel.com>2024-05-02 19:57:30 +0300
committerBjorn Helgaas <bhelgaas@google.com>2024-05-08 21:18:33 +0300
commit962f1e79e7acfb30207a378894b1bbf6742e6212 (patch)
treeed5ec51f8d91ea96148aa8cb311b034e5b853528 /drivers/cxl
parent4cece764965020c22cff7665b18a012006359095 (diff)
downloadlinux-962f1e79e7acfb30207a378894b1bbf6742e6212.tar.xz
PCI/CXL: Move CXL Vendor ID to pci_ids.h
Move PCI_DVSEC_VENDOR_ID_CXL in CXL private code to PCI_VENDOR_ID_CXL in pci_ids.h in order to be utilized in PCI subsystem. While the CXL Vendor ID (0x1e98) is not listed in the PCI SIG "Member Companies" database at https://pcisig.com/membership/member-companies, the SIG has confirmed that it is reserved by CXL. Link: https://lore.kernel.org/r/20240502165851.1948523-2-dave.jiang@intel.com Suggested-by: Bjorn Helgaas <helgaas@kernel.org> Link: https://lore.kernel.org/linux-cxl/20240402172323.GA1818777@bhelgaas/ Signed-off-by: Dave Jiang <dave.jiang@intel.com> [bhelgaas: update commit log] Signed-off-by: Bjorn Helgaas <bhelgaas@google.com> Reviewed-by: Kuppuswamy Sathyanarayanan <sathyanarayanan.kuppuswamy@linux.intel.com> Reviewed-by: Dan Williams <dan.j.williams@intel.com>
Diffstat (limited to 'drivers/cxl')
-rw-r--r--drivers/cxl/core/pci.c6
-rw-r--r--drivers/cxl/core/regs.c2
-rw-r--r--drivers/cxl/cxlpci.h1
-rw-r--r--drivers/cxl/pci.c2
4 files changed, 5 insertions, 6 deletions
diff --git a/drivers/cxl/core/pci.c b/drivers/cxl/core/pci.c
index 0df09bd79408..c496a9710d62 100644
--- a/drivers/cxl/core/pci.c
+++ b/drivers/cxl/core/pci.c
@@ -525,7 +525,7 @@ static int cxl_cdat_get_length(struct device *dev,
__le32 response[2];
int rc;
- rc = pci_doe(doe_mb, PCI_DVSEC_VENDOR_ID_CXL,
+ rc = pci_doe(doe_mb, PCI_VENDOR_ID_CXL,
CXL_DOE_PROTOCOL_TABLE_ACCESS,
&request, sizeof(request),
&response, sizeof(response));
@@ -555,7 +555,7 @@ static int cxl_cdat_read_table(struct device *dev,
__le32 request = CDAT_DOE_REQ(entry_handle);
int rc;
- rc = pci_doe(doe_mb, PCI_DVSEC_VENDOR_ID_CXL,
+ rc = pci_doe(doe_mb, PCI_VENDOR_ID_CXL,
CXL_DOE_PROTOCOL_TABLE_ACCESS,
&request, sizeof(request),
rsp, sizeof(*rsp) + remaining);
@@ -640,7 +640,7 @@ void read_cdat_data(struct cxl_port *port)
if (!pdev)
return;
- doe_mb = pci_find_doe_mailbox(pdev, PCI_DVSEC_VENDOR_ID_CXL,
+ doe_mb = pci_find_doe_mailbox(pdev, PCI_VENDOR_ID_CXL,
CXL_DOE_PROTOCOL_TABLE_ACCESS);
if (!doe_mb) {
dev_dbg(dev, "No CDAT mailbox\n");
diff --git a/drivers/cxl/core/regs.c b/drivers/cxl/core/regs.c
index 372786f80955..da52fc9e234b 100644
--- a/drivers/cxl/core/regs.c
+++ b/drivers/cxl/core/regs.c
@@ -313,7 +313,7 @@ int cxl_find_regblock_instance(struct pci_dev *pdev, enum cxl_regloc_type type,
.resource = CXL_RESOURCE_NONE,
};
- regloc = pci_find_dvsec_capability(pdev, PCI_DVSEC_VENDOR_ID_CXL,
+ regloc = pci_find_dvsec_capability(pdev, PCI_VENDOR_ID_CXL,
CXL_DVSEC_REG_LOCATOR);
if (!regloc)
return -ENXIO;
diff --git a/drivers/cxl/cxlpci.h b/drivers/cxl/cxlpci.h
index 93992a1c8eec..4da07727ab9c 100644
--- a/drivers/cxl/cxlpci.h
+++ b/drivers/cxl/cxlpci.h
@@ -13,7 +13,6 @@
* "DVSEC" redundancies removed. When obvious, abbreviations may be used.
*/
#define PCI_DVSEC_HEADER1_LENGTH_MASK GENMASK(31, 20)
-#define PCI_DVSEC_VENDOR_ID_CXL 0x1E98
/* CXL 2.0 8.1.3: PCIe DVSEC for CXL Device */
#define CXL_DVSEC_PCIE_DEVICE 0
diff --git a/drivers/cxl/pci.c b/drivers/cxl/pci.c
index 2ff361e756d6..110478573296 100644
--- a/drivers/cxl/pci.c
+++ b/drivers/cxl/pci.c
@@ -817,7 +817,7 @@ static int cxl_pci_probe(struct pci_dev *pdev, const struct pci_device_id *id)
cxlds->rcd = is_cxl_restricted(pdev);
cxlds->serial = pci_get_dsn(pdev);
cxlds->cxl_dvsec = pci_find_dvsec_capability(
- pdev, PCI_DVSEC_VENDOR_ID_CXL, CXL_DVSEC_PCIE_DEVICE);
+ pdev, PCI_VENDOR_ID_CXL, CXL_DVSEC_PCIE_DEVICE);
if (!cxlds->cxl_dvsec)
dev_warn(&pdev->dev,
"Device DVSEC not present, skip CXL.mem init\n");