summaryrefslogtreecommitdiff
path: root/drivers/thermal/cpufreq_cooling.c
diff options
context:
space:
mode:
authorLinus Torvalds <torvalds@linux-foundation.org>2020-10-17 20:40:22 +0300
committerLinus Torvalds <torvalds@linux-foundation.org>2020-10-17 20:40:22 +0300
commit5a77b6a0131f7197e1a037f65fc7cbabcb4fe680 (patch)
tree78259db0fae2871b2ad6a6ec8dffe2e652a7418b /drivers/thermal/cpufreq_cooling.c
parent071a0578b0ce0b0e543d1e38ee6926b9cc21c198 (diff)
parent48b458591749d35c927351b4960b49e35af30fe6 (diff)
downloadlinux-5a77b6a0131f7197e1a037f65fc7cbabcb4fe680.tar.xz
Merge tag 'thermal-v5.10-rc1' of git://git.kernel.org/pub/scm/linux/kernel/git/thermal/linux
Pull thermal updates from Daniel Lezcano: - Fix Kconfig typo "acces" -> "access" (Colin Ian King) - Use dev_error_probe() to simplify the error handling on imx and imx8 platforms (Anson Huang) - Use dedicated kobj_to_dev() instead of container_of() in the sysfs core code (Tian Tao) - Fix coding style by adding braces to a one line conditional statement on rcar (Geert Uytterhoeven) - Add DT binding documentation for the r8a774e1 platform and update the Kconfig description supporting RZ/G2 SoCs (Lad Prabhakar) - Simplify the return expression of stm_thermal_prepare on the stm32 platform (Qinglang Miao) - Fix the unit in the function documentation for the idle injection cooling device (Zhuguang Qing) - Remove an unecessary mutex_init() in the core code (Qinglang Miao) - Add support for keep alive events in the core code and the specific int340x (Srinivas Pandruvada) - Remove unused thermal zone variable in devfreq and cpufreq cooling devices (Zhuguang Qing) - Add the A100's THS controller support (Yangtao Li) - Add power management on the omap3's bandgap sensor (Adam Ford) - Fix a missing nlmsg_free in the netlink core error path (Jing Xiangfeng) * tag 'thermal-v5.10-rc1' of git://git.kernel.org/pub/scm/linux/kernel/git/thermal/linux: thermal: core: Adding missing nlmsg_free() in thermal_genl_sampling_temp() thermal: ti-soc-thermal: Enable addition power management thermal: sun8i: Add A100's THS controller support thermal: sun8i: add TEMP_CALIB_MASK for calibration data in sun50i_h6_ths_calibrate dt-bindings: thermal: sun8i: Add binding for A100's THS controller thermal: cooling: Remove unused variable *tz thermal: int340x: Add keep alive response method thermal: core: Add new event for sending keep alive notifications thermal: int340x: Provide notification for OEM variable change thermal: core: remove unnecessary mutex_init() thermal/idle_inject: Fix comment of idle_duration_us and name of latency_ns thermal: Kconfig: Update description for RCAR_GEN3_THERMAL config thermal: stm32: simplify the return expression of stm_thermal_prepare() dt-bindings: thermal: rcar-gen3-thermal: Add r8a774e1 support thermal: rcar_thermal: Add missing braces to conditional statement thermal: Use kobj_to_dev() instead of container_of() thermal: imx8mm: Use dev_err_probe() to simplify error handling thermal: imx: Use dev_err_probe() to simplify error handling drivers: thermal: Kconfig: fix spelling mistake "acces" -> "access"
Diffstat (limited to 'drivers/thermal/cpufreq_cooling.c')
-rw-r--r--drivers/thermal/cpufreq_cooling.c8
1 files changed, 1 insertions, 7 deletions
diff --git a/drivers/thermal/cpufreq_cooling.c b/drivers/thermal/cpufreq_cooling.c
index 6cf23a54e853..cc2959f22f01 100644
--- a/drivers/thermal/cpufreq_cooling.c
+++ b/drivers/thermal/cpufreq_cooling.c
@@ -182,7 +182,6 @@ static u32 get_dynamic_power(struct cpufreq_cooling_device *cpufreq_cdev,
/**
* cpufreq_get_requested_power() - get the current power
* @cdev: &thermal_cooling_device pointer
- * @tz: a valid thermal zone device pointer
* @power: pointer in which to store the resulting power
*
* Calculate the current power consumption of the cpus in milliwatts
@@ -203,7 +202,6 @@ static u32 get_dynamic_power(struct cpufreq_cooling_device *cpufreq_cdev,
* Return: 0 on success, -E* if getting the static power failed.
*/
static int cpufreq_get_requested_power(struct thermal_cooling_device *cdev,
- struct thermal_zone_device *tz,
u32 *power)
{
unsigned long freq;
@@ -253,7 +251,6 @@ static int cpufreq_get_requested_power(struct thermal_cooling_device *cdev,
/**
* cpufreq_state2power() - convert a cpu cdev state to power consumed
* @cdev: &thermal_cooling_device pointer
- * @tz: a valid thermal zone device pointer
* @state: cooling device state to be converted
* @power: pointer in which to store the resulting power
*
@@ -266,7 +263,6 @@ static int cpufreq_get_requested_power(struct thermal_cooling_device *cdev,
* when calculating the static power.
*/
static int cpufreq_state2power(struct thermal_cooling_device *cdev,
- struct thermal_zone_device *tz,
unsigned long state, u32 *power)
{
unsigned int freq, num_cpus, idx;
@@ -288,7 +284,6 @@ static int cpufreq_state2power(struct thermal_cooling_device *cdev,
/**
* cpufreq_power2state() - convert power to a cooling device state
* @cdev: &thermal_cooling_device pointer
- * @tz: a valid thermal zone device pointer
* @power: power in milliwatts to be converted
* @state: pointer in which to store the resulting state
*
@@ -306,8 +301,7 @@ static int cpufreq_state2power(struct thermal_cooling_device *cdev,
* device.
*/
static int cpufreq_power2state(struct thermal_cooling_device *cdev,
- struct thermal_zone_device *tz, u32 power,
- unsigned long *state)
+ u32 power, unsigned long *state)
{
unsigned int target_freq;
u32 last_load, normalised_power;