diff options
author | Bastian Stender <bst@pengutronix.de> | 2018-06-08 12:06:39 +0300 |
---|---|---|
committer | Rafael J. Wysocki <rafael.j.wysocki@intel.com> | 2018-07-02 12:26:36 +0300 |
commit | a1d0015423920672c3f32e69bd9feef2ec629b57 (patch) | |
tree | 59141b92e8d8fcb30c54cadf3617e9574f4b0e62 /drivers/thermal/imx_thermal.c | |
parent | 1111b7836c80ec4094318e1dfb3a5abe6df95afb (diff) | |
download | linux-a1d0015423920672c3f32e69bd9feef2ec629b57.tar.xz |
cpufreq: imx6q/thermal: imx: register cooling device depending on OF
The cooling device should be part of the i.MX cpufreq driver, but it
cannot be removed for the sake of DT stability. So turn the cooling
device registration into a separate function and perform the
registration only if the CPU OF node does not have the #cooling-cells
property.
Use of_cpufreq_power_cooling_register in imx_thermal code to link the
cooling device to the device tree node provided.
This makes it possible to bind the cpufreq cooling device to a custom
thermal zone via a cooling-maps entry like:
cooling-maps {
map0 {
trip = <&board_alert>;
cooling-device = <&cpu0 THERMAL_NO_LIMIT THERMAL_NO_LIMIT>;
};
};
Assuming a cpu node exists with label "cpu0" and #cooling-cells
property.
Signed-off-by: Bastian Stender <bst@pengutronix.de>
Reviewed-by: Lucas Stach <l.stach@pengutronix.de>
Signed-off-by: Rafael J. Wysocki <rafael.j.wysocki@intel.com>
Diffstat (limited to 'drivers/thermal/imx_thermal.c')
-rw-r--r-- | drivers/thermal/imx_thermal.c | 28 |
1 files changed, 24 insertions, 4 deletions
diff --git a/drivers/thermal/imx_thermal.c b/drivers/thermal/imx_thermal.c index 334d98be03b9..cbfcca828cd7 100644 --- a/drivers/thermal/imx_thermal.c +++ b/drivers/thermal/imx_thermal.c @@ -3,6 +3,7 @@ // Copyright 2013 Freescale Semiconductor, Inc. #include <linux/clk.h> +#include <linux/cpu.h> #include <linux/cpufreq.h> #include <linux/cpu_cooling.h> #include <linux/delay.h> @@ -644,6 +645,27 @@ static const struct of_device_id of_imx_thermal_match[] = { }; MODULE_DEVICE_TABLE(of, of_imx_thermal_match); +/* + * Create cooling device in case no #cooling-cells property is available in + * CPU node + */ +static int imx_thermal_register_legacy_cooling(struct imx_thermal_data *data) +{ + struct device_node *np = of_get_cpu_node(data->policy->cpu, NULL); + int ret; + + if (!np || !of_find_property(np, "#cooling-cells", NULL)) { + data->cdev = cpufreq_cooling_register(data->policy); + if (IS_ERR(data->cdev)) { + ret = PTR_ERR(data->cdev); + cpufreq_cpu_put(data->policy); + return ret; + } + } + + return 0; +} + static int imx_thermal_probe(struct platform_device *pdev) { struct imx_thermal_data *data; @@ -724,12 +746,10 @@ static int imx_thermal_probe(struct platform_device *pdev) return -EPROBE_DEFER; } - data->cdev = cpufreq_cooling_register(data->policy); - if (IS_ERR(data->cdev)) { - ret = PTR_ERR(data->cdev); + ret = imx_thermal_register_legacy_cooling(data); + if (ret) { dev_err(&pdev->dev, "failed to register cpufreq cooling device: %d\n", ret); - cpufreq_cpu_put(data->policy); return ret; } |