summaryrefslogtreecommitdiff
path: root/Documentation/hwmon/aquacomputer_d5next.rst
AgeCommit message (Collapse)AuthorFilesLines
2023-06-08hwmon: (aquacomputer_d5next) Add support for Aquacomputer LeakshieldAleksa Savic1-0/+9
Extend aquacomputer_d5next driver to expose various hardware sensors of the Aquacomputer Leakshield leak prevention system, which communicates through a proprietary USB HID protocol. Implemented by Noah Bergbauer [1]. Two temperature sensors are exposed, along with pressure (current, min, max and target), reservoir volume (total and filled), pump speed and flow. Pump speed and flow values are user provided and allow the Leakshield to optimize its operation. Writing them to the device is subject of future patches. [1] https://github.com/aleksamagicka/aquacomputer_d5next-hwmon/pull/41 Originally-from: Noah Bergbauer <main@ehvag.de> Signed-off-by: Aleksa Savic <savicaleksa83@gmail.com> Link: https://lore.kernel.org/r/20230520095447.509287-3-savicaleksa83@gmail.com Signed-off-by: Guenter Roeck <linux@roeck-us.net>
2023-04-21hwmon: (aquacomputer_d5next) Add support for Aquacomputer Aquastream XTAleksa Savic1-0/+5
Extend aquacomputer_d5next driver to expose various hardware sensors of the Aquacomputer Aquastream XT watercooling pump, which communicates through a proprietary USB HID protocol. Implemented by Leonard Anderweit [1] [2]. Coolant temp, fan IC and external temp sensor readings are available, along with speed and voltage of both the pump and optionally connected fan. It also exposes pump current. Additionally, serial number and firmware version are exposed through debugfs. [1] https://github.com/aleksamagicka/aquacomputer_d5next-hwmon/pull/46 [2] https://github.com/aleksamagicka/aquacomputer_d5next-hwmon/pull/49 Originally-from: Leonard Anderweit <leonard.anderweit@gmail.com> Signed-off-by: Aleksa Savic <savicaleksa83@gmail.com> Link: https://lore.kernel.org/r/20230416181702.9892-1-savicaleksa83@gmail.com Signed-off-by: Guenter Roeck <linux@roeck-us.net>
2023-04-19hwmon: (aquacomputer_d5next) Add fan PWM control for AquaeroLeonard Anderweit1-1/+2
Add the option to control fan PWM on Aquacomputer Aquaero. The Aquaero is the most complex Aquacomputer device, control is therefore more complicated then on already supported devices. Setting PWM requires multiple steps. First, an internal static PWM controller is set to the desired PWM value. Second, the fan is set to use that PWM controller. Last, the minimum and maximum accepted PWM values of the fan are set to allow all possible PWM values. Signed-off-by: Leonard Anderweit <leonard.anderweit@gmail.com> Link: https://lore.kernel.org/r/20230214220221.15003-7-leonard.anderweit@gmail.com Signed-off-by: Guenter Roeck <linux@roeck-us.net>
2023-04-19hwmon: (aquacomputer_d5next) Add temperature offset control for AquaeroLeonard Anderweit1-2/+2
Adds control over the Aquacomputer Aquaero temperature offset for all eight temperature sensors. Signed-off-by: Leonard Anderweit <leonard.anderweit@gmail.com> Link: https://lore.kernel.org/r/20230214220221.15003-6-leonard.anderweit@gmail.com Signed-off-by: Guenter Roeck <linux@roeck-us.net>
2023-02-03hwmon: (aquacomputer_d5next) Add support for Aquacomputer Aquastream UltimateAleksa Savic1-0/+5
Extend aquacomputer_d5next driver to expose various hardware sensors of the Aquacomputer Aquastream Ultimate watercooling pump, which communicates through a proprietary USB HID protocol. Coolant temp and external temp sensor readings are available, along with speed, power, voltage and current of both the pump and optionally connected fan. It also exposes pressure and flow speed readings. Additionally, serial number and firmware version are exposed through debugfs. Tested by a user on Github [1]. [1] https://github.com/aleksamagicka/aquacomputer_d5next-hwmon/issues/50 Signed-off-by: Aleksa Savic <savicaleksa83@gmail.com> Link: https://lore.kernel.org/r/20230203120324.579808-1-savicaleksa83@gmail.com Signed-off-by: Guenter Roeck <linux@roeck-us.net>
2023-02-03hwmon: (aquacomputer_d5next) Add support for Aquacomputer Poweradjust 3Aleksa Savic1-0/+3
Extend aquacomputer_d5next driver to expose the temp sensor of the Aquacomputer Poweradjust 3 fan controller, which communicates through a proprietary USB HID protocol. The Poweradjust 3 is not currently known to expose firmware version and serial number, so don't create debugfs entries if their values can't be retrieved. Tested by a user on Github [1]. [1] https://github.com/aleksamagicka/aquacomputer_d5next-hwmon/issues/57 Signed-off-by: Aleksa Savic <savicaleksa83@gmail.com> Link: https://lore.kernel.org/r/20230131101210.8095-1-savicaleksa83@gmail.com Signed-off-by: Guenter Roeck <linux@roeck-us.net>
2023-02-03hwmon: (aquacomputer_d5next) Add support for reading calculated Aquaero sensorsAleksa Savic1-3/+3
Add support for reading four calculated virtual temp sensors on the Aquacomputer Aquaero. Values of these sensors are calculated on the device itself based on what the user configured in the official software. Configuring these sensors is not currently reverse engineered. Signed-off-by: Aleksa Savic <savicaleksa83@gmail.com> Link: https://lore.kernel.org/r/20230101190056.1357124-1-savicaleksa83@gmail.com Signed-off-by: Guenter Roeck <linux@roeck-us.net>
2023-02-03hwmon: (aquacomputer_d5next) Support sensors for Aquacomputer AquaeroLeonard Anderweit1-0/+5
Add support for reading sensors of the Aquacomputer Aquaero 5/6 fan controllers. These fan controllers supports 4 fans, 8 physical temperature sensors, 8 virtual temperature sensors and 2 flow sensors. Temperature and flow sensor reading implemented by Aleksa Savic [1] [2] [3]. [1] https://github.com/aleksamagicka/aquacomputer_d5next-hwmon/pull/31 [2] https://github.com/aleksamagicka/aquacomputer_d5next-hwmon/pull/51 [3] https://github.com/aleksamagicka/aquacomputer_d5next-hwmon/pull/55 Originally-from: Aleksa Savic <savicaleksa83@gmail.com> Signed-off-by: Leonard Anderweit <leonard.anderweit@gmail.com> Link: https://lore.kernel.org/r/20221218113131.3752-7-leonard.anderweit@gmail.com Signed-off-by: Guenter Roeck <linux@roeck-us.net>
2022-12-05hwmon: (aquacomputer_d5next) Add support for Quadro flow sensor pulsesAleksa Savic1-1/+2
Add support for reading and writing flow sensor pulses value on the Aquacomputer Quadro. Implemented by Leonard Anderweit [1]. [1] https://github.com/aleksamagicka/aquacomputer_d5next-hwmon/pull/45 Originally-from: Leonard Anderweit <leonard.anderweit@gmail.com> Signed-off-by: Aleksa Savic <savicaleksa83@gmail.com> Link: https://lore.kernel.org/r/20221126071313.34356-1-savicaleksa83@gmail.com Signed-off-by: Guenter Roeck <linux@roeck-us.net>
2022-12-05hwmon: (aquacomputer_d5next) Add support for temperature sensor offsetsAleksa Savic1-0/+1
Add support for reading and writing temperature sensor offsets on the Aquacomputer D5 Next, Farbwerk 360, Octo and Quadro, for which the needed offsets are known. Implemented by Leonard Anderweit [1]. [1] https://github.com/aleksamagicka/aquacomputer_d5next-hwmon/pull/22 Originally-from: Leonard Anderweit <leonard.anderweit@gmail.com> Signed-off-by: Aleksa Savic <savicaleksa83@gmail.com> Link: https://lore.kernel.org/r/20221024151039.7222-1-savicaleksa83@gmail.com Signed-off-by: Guenter Roeck <linux@roeck-us.net>
2022-09-19hwmon: (aquacomputer_d5next) Add support for Aquacomputer High Flow NextAleksa Savic1-0/+5
Extend aquacomputer_d5next driver to expose various hardware sensors of the Aquacomputer High Flow Next flow sensor, which communicates through a proprietary USB HID protocol. The High Flow Next exposes +5V voltages, water quality, conductivity and flow readings. A temperature sensor can be connected to it, in which case it provides its reading and an estimation of the dissipated/absorbed power in the liquid cooling loop. Additionally, serial number and firmware version are exposed through debugfs. Registry offsets were discovered and tested by users on Github [1] [2]. [1] https://github.com/aleksamagicka/aquacomputer_d5next-hwmon/issues/8 [2] https://github.com/aleksamagicka/aquacomputer_d5next-hwmon/pull/34 Signed-off-by: Aleksa Savic <savicaleksa83@gmail.com> Link: https://lore.kernel.org/r/20220907100739.806571-1-savicaleksa83@gmail.com Signed-off-by: Guenter Roeck <linux@roeck-us.net>
2022-09-19hwmon: (aquacomputer_d5next) Add support for reading virtual temp sensorsAleksa Savic1-13/+19
Add support for reading virtual temperature sensors for the D5 Next, Octo, Quadro and Farbwerk 360. Virtual temperature sensors are written to the device by the user, pulling from an arbitrary value source. Writing to them is not yet reverse engineered, so the only way to set them for now is to use the official software. Signed-off-by: Aleksa Savic <savicaleksa83@gmail.com> Link: https://lore.kernel.org/r/20220817121441.112198-1-savicaleksa83@gmail.com Signed-off-by: Guenter Roeck <linux@roeck-us.net>
2022-07-27hwmon: (aquacomputer_d5next) Add support for Aquacomputer Quadro fan controllerAleksa Savic1-6/+11
Extend aquacomputer_d5next driver to expose hardware temperature sensors and fans of the Aquacomputer Quadro fan controller, which communicates through a proprietary USB HID protocol. Implemented by Jack Doan [1]. Four temperature sensors and PWM controllable fans are available. The liquid flow sensor is also exposed, implemented by Leonard Anderweit [2]. Additionally, serial number, firmware version and power-on count are exposed through debugfs. This driver has been tested on x86_64. [1] https://github.com/aleksamagicka/aquacomputer_d5next-hwmon/pull/5 [2] https://github.com/aleksamagicka/aquacomputer_d5next-hwmon/pull/9 Originally-from: Jack Doan <me@jackdoan.com> Originally-from: Leonard Anderweit <leonard.anderweit@gmail.com> Signed-off-by: Aleksa Savic <savicaleksa83@gmail.com> Link: https://lore.kernel.org/r/20220727100606.9328-1-savicaleksa83@gmail.com Signed-off-by: Guenter Roeck <linux@roeck-us.net>
2022-05-20hwmon: (aquacomputer_d5next) Add support for Aquacomputer FarbwerkJack Doan1-1/+2
Extend aquacomputer_d5next driver to expose hardware temperature sensors of the Aquacomputer Farbwerk RGB controller, which communicates through a proprietary USB HID protocol. Four temperature sensors are available. Additionally, serial number and firmware version are exposed through debugfs. Also, add Jack Doan to MAINTAINERS for this driver. Signed-off-by: Jack Doan <me@jackdoan.com> Signed-off-by: Aleksa Savic <savicaleksa83@gmail.com> Link: https://lore.kernel.org/r/YmTcrq8Gzel0zYYD@jackdesk Signed-off-by: Guenter Roeck <linux@roeck-us.net>
2022-05-17hwmon: (aquacomputer_d5next) Add support for Aquacomputer OctoAleksa Savic1-0/+4
Extend aquacomputer_d5next driver to expose hardware temperature sensors and fans of the Aquacomputer Octo fan controller, which communicates through a proprietary USB HID protocol. Four temperature sensors and eight PWM controllable fans are available. Additionally, serial number, firmware version and power-on count are exposed through debugfs. This driver has been tested on x86_64. Signed-off-by: Aleksa Savic <savicaleksa83@gmail.com> Link: https://lore.kernel.org/r/20220404134212.9690-1-savicaleksa83@gmail.com [groeck: Add missing "select CRC16"] Signed-off-by: Guenter Roeck <linux@roeck-us.net>
2022-02-28hwmon: (aquacomputer_d5next) Add support for Aquacomputer Farbwerk 360Aleksa Savic1-26/+23
Extend aquacomputer_d5next driver to expose hardware temperature sensors of the Aquacomputer Farbwerk 360 RGB controller, which communicates through a proprietary USB HID protocol. Four temperature sensors are available. Additionally, serial number and firmware version are exposed through debugfs. This driver has been tested on x86_64. Signed-off-by: Aleksa Savic <savicaleksa83@gmail.com> Signed-off-by: Guenter Roeck <linux@roeck-us.net>
2021-08-28hwmon: add driver for Aquacomputer D5 NextAleksa Savic1-0/+61
This driver exposes hardware sensors of the Aquacomputer D5 Next watercooling pump, which communicates through a proprietary USB HID protocol. Available sensors are pump and fan speed, power, voltage and current, as well as coolant temperature. Also available through debugfs are the serial number, firmware version and power-on count. Attaching a fan is optional and allows it to be controlled using temperature curves directly from the pump. If it's not connected, the fan-related sensors will report zeroes. The pump can be configured either through software or via its physical interface. Configuring the pump through this driver is not implemented, as it seems to require sending it a complete configuration. That includes addressable RGB LEDs, for which there is no standard sysfs interface. Thus, that task is better suited for userspace tools. This driver has been tested on x86_64, both in-kernel and as a module. Signed-off-by: Aleksa Savic <savicaleksa83@gmail.com> Signed-off-by: Guenter Roeck <linux@roeck-us.net>