2020-04-25iio: chemical: atlas-sensor: add RTD-SM module supportMatt Ranostay1-0/+29
Atlas Scientific RTD-SM OEM sensor reads temperature using resistance temperature detector technology. Signed-off-by: Matt Ranostay <matt.ranostay@konsulko.com> Signed-off-by: Jonathan Cameron <Jonathan.Cameron@huawei.com>
2020-04-19iio:chemical:atlas-sensor: Drop unnecessary explicit casts in ↵Jonathan Cameron1-4/+3
regmap_bulk_read calls regmap_bulk_read takes a void * for its val parameter. It certainly makes no sense to cast to a (u8 *) + no need to explicitly cast at all when converting another pointer type to void *. Signed-off-by: Jonathan Cameron <Jonathan.Cameron@huawei.com> Acked-by: Matt Ranostay <matt.ranostay@konsulko.com> Reviewed-by: Andy Shevchenko <andy.shevchenko@gmail.com> Reviewed-by: Alexandru Ardelean <alexandru.ardelean@analog.com>
2020-03-08iio: chemical: atlas-sensor: add DO-SM module supportMatt Ranostay1-4/+60
Atlas Scientific DO-SM OEM sensor reads disolved oxygen in a solution. This is reported back as mg/L which maps directly to ppm and so the IIO_CONCENTRATION channel type can be used. Signed-off-by: Matt Ranostay <matt.ranostay@konsulko.com> Signed-off-by: Jonathan Cameron <Jonathan.Cameron@huawei.com>
2020-03-08iio: chemical: atlas-sensor: allow probe without interrupt lineMatt Ranostay1-15/+18
Sensors don't actually need a interrupt line to give valid readings, and can triggered with CONFIG_IIO_HRTIMER_TRIGGER as well. Remove the required check for interrupt, and continue along in the probe function. Signed-off-by: Matt Ranostay <matt.ranostay@konsulko.com> Signed-off-by: Jonathan Cameron <Jonathan.Cameron@huawei.com>
2020-01-12iio: chemical: atlas-sensor: add helper function atlas_buffer_num_channels()Matt Ranostay1-1/+12
Add helper function to detect the number of channels to output in trigger handler. This is based on IIO_TIMESTAMP channel being the delimiter between input and output channels. Signed-off-by: Matt Ranostay <matt.ranostay@konsulko.com> Signed-off-by: Jonathan Cameron <Jonathan.Cameron@huawei.com>
2019-12-29iio: chemical: atlas-ph-sensor: rename atlas-ph-sensor to atlas-sensorMatt Ranostay1-0/+684
Since the orginal scope of the driver was to only support the pH product from Atlas it has evolved to other sensors. Rename the file, driver name, and regmap to atlas-sensor which reflects this, although keep CONFIG_ATLAS_PH_SENSOR to not cause regressions with current configurations. Signed-off-by: Matt Ranostay <matt.ranostay@konsulko.com> Signed-off-by: Jonathan Cameron <Jonathan.Cameron@huawei.com>