regulator: bd718x7: Suopport configuring UVP/OVP state
The ROHM BD71837/47/50/78 do support enabling/disabling the under/over voltage protection. Add support for enabling/disabling the protection according to the device-tree information. Signed-off-by: Matti Vaittinen <matti.vaittinen@fi.rohmeurope.com> Link: https://lore.kernel.org/r/20210705105416.GA1189560@localhost.localdomain Signed-off-by: Mark Brown <broonie@kernel.org>
Diffstat (limited to 'drivers/regulator')
-rw-r--r--drivers/regulator/bd718x7-regulator.c369
1 files changed, 260 insertions, 109 deletions
diff --git a/drivers/regulator/bd718x7-regulator.c b/drivers/regulator/bd718x7-regulator.c
index b1eb46961993..d60fccedb250 100644
--- a/drivers/regulator/bd718x7-regulator.c
+++ b/drivers/regulator/bd718x7-regulator.c
@@ -55,7 +55,8 @@
#define BD718XX_HWOPNAME(swopname) swopname##_hwcontrol
#define BD718XX_OPS(name, _list_voltage, _map_voltage, _set_voltage_sel, \
- _get_voltage_sel, _set_voltage_time_sel, _set_ramp_delay) \
+ _get_voltage_sel, _set_voltage_time_sel, _set_ramp_delay, \
+ _set_uvp, _set_ovp) \
static const struct regulator_ops name = { \
.enable = regulator_enable_regmap, \
.disable = regulator_disable_regmap, \
@@ -66,6 +67,8 @@ static const struct regulator_ops name = { \
.get_voltage_sel = (_get_voltage_sel), \
.set_voltage_time_sel = (_set_voltage_time_sel), \
.set_ramp_delay = (_set_ramp_delay), \
+ .set_under_voltage_protection = (_set_uvp), \
+ .set_over_voltage_protection = (_set_ovp), \
}; \
\
static const struct regulator_ops BD718XX_HWOPNAME(name) = { \
@@ -76,6 +79,8 @@ static const struct regulator_ops BD718XX_HWOPNAME(name) = { \
.get_voltage_sel = (_get_voltage_sel), \
.set_voltage_time_sel = (_set_voltage_time_sel), \
.set_ramp_delay = (_set_ramp_delay), \
+ .set_under_voltage_protection = (_set_uvp), \
+ .set_over_voltage_protection = (_set_ovp), \
} \
/*
@@ -154,17 +159,9 @@ static void voltage_change_done(struct regulator_dev *rdev, unsigned int sel,
* exceed it due to the scheduling.
*/
msleep(1);
- /*
- * Note for next hacker. The PWRGOOD should not be masked on
- * BD71847 so we will just unconditionally enable detection
- * when voltage is set.
- * If someone want's to disable PWRGOOD he must implement
- * caching and restoring the old value here. I am not
- * aware of such use-cases so for the sake of the simplicity
- * we just always enable PWRGOOD here.
- */
- ret = regmap_update_bits(rdev->regmap, BD718XX_REG_MVRFLTMASK2,
- *mask, 0);
+
+ ret = regmap_clear_bits(rdev->regmap, BD718XX_REG_MVRFLTMASK2,
+ *mask);
if (ret)
dev_err(&rdev->dev,
"Failed to re-enable voltage monitoring (%d)\n",
@@ -208,12 +205,27 @@ static int voltage_change_prepare(struct regulator_dev *rdev, unsigned int sel,
* time configurable.
*/
if (new > now) {
+ int tmp;
+ int prot_bit;
int ldo_offset = rdev->desc->id - BD718XX_LDO1;
- *mask = BD718XX_LDO1_VRMON80 << ldo_offset;
- ret = regmap_update_bits(rdev->regmap,
- BD718XX_REG_MVRFLTMASK2,
- *mask, *mask);
+ prot_bit = BD718XX_LDO1_VRMON80 << ldo_offset;
+ ret = regmap_read(rdev->regmap, BD718XX_REG_MVRFLTMASK2,
+ &tmp);
+ if (ret) {
+ dev_err(&rdev->dev,
+ "Failed to read voltage monitoring state\n");
+ return ret;
+ }
+
+ if (!(tmp & prot_bit)) {
+ /* We disable protection if it was enabled... */
+ ret = regmap_set_bits(rdev->regmap,
+ BD718XX_REG_MVRFLTMASK2,
+ prot_bit);
+ /* ...and we also want to re-enable it */
+ *mask = prot_bit;
+ }
if (ret) {
dev_err(&rdev->dev,
"Failed to stop voltage monitoring\n");
@@ -267,99 +279,6 @@ static int bd71837_set_voltage_sel_pickable_restricted(
}
/*
- * OPS common for BD71847 and BD71850
- */
-BD718XX_OPS(bd718xx_pickable_range_ldo_ops,
- regulator_list_voltage_pickable_linear_range, NULL,
- bd718xx_set_voltage_sel_pickable_restricted,
- regulator_get_voltage_sel_pickable_regmap, NULL, NULL);
-
-/* BD71847 and BD71850 LDO 5 is by default OFF at RUN state */
-static const struct regulator_ops bd718xx_ldo5_ops_hwstate = {
- .is_enabled = never_enabled_by_hwstate,
- .list_voltage = regulator_list_voltage_pickable_linear_range,
- .set_voltage_sel = bd718xx_set_voltage_sel_pickable_restricted,
- .get_voltage_sel = regulator_get_voltage_sel_pickable_regmap,
-};
-
-BD718XX_OPS(bd718xx_pickable_range_buck_ops,
- regulator_list_voltage_pickable_linear_range, NULL,
- regulator_set_voltage_sel_pickable_regmap,
- regulator_get_voltage_sel_pickable_regmap,
- regulator_set_voltage_time_sel, NULL);
-
-BD718XX_OPS(bd718xx_ldo_regulator_ops, regulator_list_voltage_linear_range,
- NULL, bd718xx_set_voltage_sel_restricted,
- regulator_get_voltage_sel_regmap, NULL, NULL);
-
-BD718XX_OPS(bd718xx_ldo_regulator_nolinear_ops, regulator_list_voltage_table,
- NULL, bd718xx_set_voltage_sel_restricted,
- regulator_get_voltage_sel_regmap, NULL, NULL);
-
-BD718XX_OPS(bd718xx_buck_regulator_ops, regulator_list_voltage_linear_range,
- NULL, regulator_set_voltage_sel_regmap,
- regulator_get_voltage_sel_regmap, regulator_set_voltage_time_sel,
- NULL);
-
-BD718XX_OPS(bd718xx_buck_regulator_nolinear_ops, regulator_list_voltage_table,
- regulator_map_voltage_ascend, regulator_set_voltage_sel_regmap,
- regulator_get_voltage_sel_regmap, regulator_set_voltage_time_sel,
- NULL);
-
-/*
- * OPS for BD71837
- */
-BD718XX_OPS(bd71837_pickable_range_ldo_ops,
- regulator_list_voltage_pickable_linear_range, NULL,
- bd71837_set_voltage_sel_pickable_restricted,
- regulator_get_voltage_sel_pickable_regmap, NULL, NULL);
-
-BD718XX_OPS(bd71837_pickable_range_buck_ops,
- regulator_list_voltage_pickable_linear_range, NULL,
- bd71837_set_voltage_sel_pickable_restricted,
- regulator_get_voltage_sel_pickable_regmap,
- regulator_set_voltage_time_sel, NULL);
-
-BD718XX_OPS(bd71837_ldo_regulator_ops, regulator_list_voltage_linear_range,
- NULL, bd71837_set_voltage_sel_restricted,
- regulator_get_voltage_sel_regmap, NULL, NULL);
-
-BD718XX_OPS(bd71837_ldo_regulator_nolinear_ops, regulator_list_voltage_table,
- NULL, bd71837_set_voltage_sel_restricted,
- regulator_get_voltage_sel_regmap, NULL, NULL);
-
-BD718XX_OPS(bd71837_buck_regulator_ops, regulator_list_voltage_linear_range,
- NULL, bd71837_set_voltage_sel_restricted,
- regulator_get_voltage_sel_regmap, regulator_set_voltage_time_sel,
- NULL);
-
-BD718XX_OPS(bd71837_buck_regulator_nolinear_ops, regulator_list_voltage_table,
- regulator_map_voltage_ascend, bd71837_set_voltage_sel_restricted,
- regulator_get_voltage_sel_regmap, regulator_set_voltage_time_sel,
- NULL);
-/*
- * BD71837 bucks 3 and 4 support defining their enable/disable state also
- * when buck enable state is under HW state machine control. In that case the
- * bit [2] in CTRL register is used to indicate if regulator should be ON.
- */
-static const struct regulator_ops bd71837_buck34_ops_hwctrl = {
- .is_enabled = bd71837_get_buck34_enable_hwctrl,
- .list_voltage = regulator_list_voltage_linear_range,
- .set_voltage_sel = regulator_set_voltage_sel_regmap,
- .get_voltage_sel = regulator_get_voltage_sel_regmap,
- .set_voltage_time_sel = regulator_set_voltage_time_sel,
- .set_ramp_delay = regulator_set_ramp_delay_regmap,
-};
-
-/*
- * OPS for all of the ICs - BD718(37/47/50)
- */
-BD718XX_OPS(bd718xx_dvs_buck_regulator_ops, regulator_list_voltage_linear_range,
- NULL, regulator_set_voltage_sel_regmap,
- regulator_get_voltage_sel_regmap, regulator_set_voltage_time_sel,
- /* bd718xx_buck1234_set_ramp_delay */ regulator_set_ramp_delay_regmap);
-
-/*
* BD71837 BUCK1/2/3/4
* BD71847 BUCK1/2
* 0.70 to 1.30V (10mV step)
@@ -536,6 +455,238 @@ struct bd718xx_regulator_data {
int additional_init_amnt;
};
+static int bd718x7_xvp_sanity_check(struct regulator_dev *rdev, int lim_uV,
+ int severity)
+{
+ /*
+ * BD71837/47/50 ... (ICs supported by this driver) do not provide
+ * warnings, only protection
+ */
+ if (severity != REGULATOR_SEVERITY_PROT) {
+ dev_err(&rdev->dev,
+ "Unsupported Under Voltage protection level\n");
+ return -EINVAL;
+ }
+
+ /*
+ * And protection limit is not changeable. It can only be enabled
+ * or disabled
+ */
+ if (lim_uV)
+ return -EINVAL;
+
+ return 0;
+}
+
+static int bd718x7_set_ldo_uvp(struct regulator_dev *rdev, int lim_uV,
+ int severity, bool enable)
+{
+ int ldo_offset = rdev->desc->id - BD718XX_LDO1;
+ int prot_bit, ret;
+
+ ret = bd718x7_xvp_sanity_check(rdev, lim_uV, severity);
+ if (ret)
+ return ret;
+
+ prot_bit = BD718XX_LDO1_VRMON80 << ldo_offset;
+
+ if (enable)
+ return regmap_clear_bits(rdev->regmap, BD718XX_REG_MVRFLTMASK2,
+ prot_bit);
+
+ return regmap_set_bits(rdev->regmap, BD718XX_REG_MVRFLTMASK2,
+ prot_bit);
+}
+
+static int bd718x7_get_buck_prot_reg(int id, int *reg)
+{
+
+ if (id > BD718XX_BUCK8) {
+ WARN_ON(id > BD718XX_BUCK8);
+ return -EINVAL;
+ }
+
+ if (id > BD718XX_BUCK4)
+ *reg = BD718XX_REG_MVRFLTMASK0;
+ else
+ *reg = BD718XX_REG_MVRFLTMASK1;
+
+ return 0;
+}
+
+static int bd718x7_get_buck_ovp_info(int id, int *reg, int *bit)
+{
+ int ret;
+
+ ret = bd718x7_get_buck_prot_reg(id, reg);
+ if (ret)
+ return ret;
+
+ *bit = BIT((id % 4) * 2 + 1);
+
+ return 0;
+}
+
+static int bd718x7_get_buck_uvp_info(int id, int *reg, int *bit)
+{
+ int ret;
+
+ ret = bd718x7_get_buck_prot_reg(id, reg);
+ if (ret)
+ return ret;
+
+ *bit = BIT((id % 4) * 2);
+
+ return 0;
+}
+
+static int bd718x7_set_buck_uvp(struct regulator_dev *rdev, int lim_uV,
+ int severity, bool enable)
+{
+ int bit, reg, ret;
+
+ ret = bd718x7_xvp_sanity_check(rdev, lim_uV, severity);
+ if (ret)
+ return ret;
+
+ ret = bd718x7_get_buck_uvp_info(rdev->desc->id, &reg, &bit);
+ if (ret)
+ return ret;
+
+ if (enable)
+ return regmap_clear_bits(rdev->regmap, reg, bit);
+
+ return regmap_set_bits(rdev->regmap, reg, bit);
+
+}
+
+static int bd718x7_set_buck_ovp(struct regulator_dev *rdev, int lim_uV,
+ int severity,
+ bool enable)
+{
+ int bit, reg, ret;
+
+ ret = bd718x7_xvp_sanity_check(rdev, lim_uV, severity);
+ if (ret)
+ return ret;
+
+ ret = bd718x7_get_buck_ovp_info(rdev->desc->id, &reg, &bit);
+ if (ret)
+ return ret;
+
+ if (enable)
+ return regmap_clear_bits(rdev->regmap, reg, bit);
+
+ return regmap_set_bits(rdev->regmap, reg, bit);
+}
+
+/*
+ * OPS common for BD71847 and BD71850
+ */
+BD718XX_OPS(bd718xx_pickable_range_ldo_ops,
+ regulator_list_voltage_pickable_linear_range, NULL,
+ bd718xx_set_voltage_sel_pickable_restricted,
+ regulator_get_voltage_sel_pickable_regmap, NULL, NULL,
+ bd718x7_set_ldo_uvp, NULL);
+
+/* BD71847 and BD71850 LDO 5 is by default OFF at RUN state */
+static const struct regulator_ops bd718xx_ldo5_ops_hwstate = {
+ .is_enabled = never_enabled_by_hwstate,
+ .list_voltage = regulator_list_voltage_pickable_linear_range,
+ .set_voltage_sel = bd718xx_set_voltage_sel_pickable_restricted,
+ .get_voltage_sel = regulator_get_voltage_sel_pickable_regmap,
+ .set_under_voltage_protection = bd718x7_set_ldo_uvp,
+};
+
+BD718XX_OPS(bd718xx_pickable_range_buck_ops,
+ regulator_list_voltage_pickable_linear_range, NULL,
+ regulator_set_voltage_sel_pickable_regmap,
+ regulator_get_voltage_sel_pickable_regmap,
+ regulator_set_voltage_time_sel, NULL, bd718x7_set_buck_uvp,
+ bd718x7_set_buck_ovp);
+
+BD718XX_OPS(bd718xx_ldo_regulator_ops, regulator_list_voltage_linear_range,
+ NULL, bd718xx_set_voltage_sel_restricted,
+ regulator_get_voltage_sel_regmap, NULL, NULL, bd718x7_set_ldo_uvp,
+ NULL);
+
+BD718XX_OPS(bd718xx_ldo_regulator_nolinear_ops, regulator_list_voltage_table,
+ NULL, bd718xx_set_voltage_sel_restricted,
+ regulator_get_voltage_sel_regmap, NULL, NULL, bd718x7_set_ldo_uvp,
+ NULL);
+
+BD718XX_OPS(bd718xx_buck_regulator_ops, regulator_list_voltage_linear_range,
+ NULL, regulator_set_voltage_sel_regmap,
+ regulator_get_voltage_sel_regmap, regulator_set_voltage_time_sel,
+ NULL, bd718x7_set_buck_uvp, bd718x7_set_buck_ovp);
+
+BD718XX_OPS(bd718xx_buck_regulator_nolinear_ops, regulator_list_voltage_table,
+ regulator_map_voltage_ascend, regulator_set_voltage_sel_regmap,
+ regulator_get_voltage_sel_regmap, regulator_set_voltage_time_sel,
+ NULL, bd718x7_set_buck_uvp, bd718x7_set_buck_ovp);
+
+/*
+ * OPS for BD71837
+ */
+BD718XX_OPS(bd71837_pickable_range_ldo_ops,
+ regulator_list_voltage_pickable_linear_range, NULL,
+ bd71837_set_voltage_sel_pickable_restricted,
+ regulator_get_voltage_sel_pickable_regmap, NULL, NULL,
+ bd718x7_set_ldo_uvp, NULL);
+
+BD718XX_OPS(bd71837_pickable_range_buck_ops,
+ regulator_list_voltage_pickable_linear_range, NULL,
+ bd71837_set_voltage_sel_pickable_restricted,
+ regulator_get_voltage_sel_pickable_regmap,
+ regulator_set_voltage_time_sel, NULL, bd718x7_set_buck_uvp,
+ bd718x7_set_buck_ovp);
+
+BD718XX_OPS(bd71837_ldo_regulator_ops, regulator_list_voltage_linear_range,
+ NULL, bd71837_set_voltage_sel_restricted,
+ regulator_get_voltage_sel_regmap, NULL, NULL, bd718x7_set_ldo_uvp,
+ NULL);
+
+BD718XX_OPS(bd71837_ldo_regulator_nolinear_ops, regulator_list_voltage_table,
+ NULL, bd71837_set_voltage_sel_restricted,
+ regulator_get_voltage_sel_regmap, NULL, NULL, bd718x7_set_ldo_uvp,
+ NULL);
+
+BD718XX_OPS(bd71837_buck_regulator_ops, regulator_list_voltage_linear_range,
+ NULL, bd71837_set_voltage_sel_restricted,
+ regulator_get_voltage_sel_regmap, regulator_set_voltage_time_sel,
+ NULL, bd718x7_set_buck_uvp, bd718x7_set_buck_ovp);
+
+BD718XX_OPS(bd71837_buck_regulator_nolinear_ops, regulator_list_voltage_table,
+ regulator_map_voltage_ascend, bd71837_set_voltage_sel_restricted,
+ regulator_get_voltage_sel_regmap, regulator_set_voltage_time_sel,
+ NULL, bd718x7_set_buck_uvp, bd718x7_set_buck_ovp);
+/*
+ * BD71837 bucks 3 and 4 support defining their enable/disable state also
+ * when buck enable state is under HW state machine control. In that case the
+ * bit [2] in CTRL register is used to indicate if regulator should be ON.
+ */
+static const struct regulator_ops bd71837_buck34_ops_hwctrl = {
+ .is_enabled = bd71837_get_buck34_enable_hwctrl,
+ .list_voltage = regulator_list_voltage_linear_range,
+ .set_voltage_sel = regulator_set_voltage_sel_regmap,
+ .get_voltage_sel = regulator_get_voltage_sel_regmap,
+ .set_voltage_time_sel = regulator_set_voltage_time_sel,
+ .set_ramp_delay = regulator_set_ramp_delay_regmap,
+ .set_under_voltage_protection = bd718x7_set_buck_uvp,
+ .set_over_voltage_protection = bd718x7_set_buck_ovp,
+};
+
+/*
+ * OPS for all of the ICs - BD718(37/47/50)
+ */
+BD718XX_OPS(bd718xx_dvs_buck_regulator_ops, regulator_list_voltage_linear_range,
+ NULL, regulator_set_voltage_sel_regmap,
+ regulator_get_voltage_sel_regmap, regulator_set_voltage_time_sel,
+ regulator_set_ramp_delay_regmap, bd718x7_set_buck_uvp,
+ bd718x7_set_buck_ovp);
+
+
+
/*
* There is a HW quirk in BD71837. The shutdown sequence timings for