Age | Commit message (Collapse) | Author | Files | Lines |
|
The UID button is used to provide visual identification of the system
when pushed. Pressing the UID button toggles the UID LED. The same
action can be done via Redfish (by patching IndicatorLED from
redfish/v1/Systems/system) or the IPMI chassis identify command.
Tested:
1. Press the UID button to toggles the UID on/off
2. Turn on the UID LED via ipmi command
$ ipmitool chassis identify
3. Turn Lit/Blinking/Off UID LED via Redfish then check the IndicatorLED
values
$ curl -X PATCH --user root:0penBmc -H "Content-Type: application/json" \
-H "If-Match: *" --insecure https://BMC_IP/redfish/v1/Systems/system \
-d '{"IndicatorLED": "Lit/Blinking/Off"}'
$curl -X GET --user root:0penBmc -H "Content-Type: application/json" \
--insecure https://BMC_IP/redfish/v1/Systems/system
The IndicatorLED is "Lit/Blinking/Off"
Signed-off-by: Hieu Huynh <hieu.huynh@amperecomputing.com>
Signed-off-by: Chanh Nguyen <chanh@os.amperecomputing.com>
Change-Id: I58eeae7ac22a9d4ddd4acdfbd167095bdc74072c
|
|
Monitor the Socket 0 and Socket 1's CPU_FAULT GPIO and turn on the Fault
LED when any GPIO turns ON.
Tested:
1. Flash special SCP image to stimulate CPU Fault LED
2. Check if the Fault LED is ON.
Signed-off-by: Tung Nguyen <tung.nguyen@amperecomputing.com>
Signed-off-by: Chanh Nguyen <chanh@os.amperecomputing.com>
Change-Id: I73bf34b4361528c9c8825942ddc7f24d51589189
|
|
Add initial LED YAML and related files for Mt. Jade LED support.
Tested: Check power LED ON during BMC boot.
Signed-off-by: Hieu Cong Huynh <hieu.huynh@amperecomputing.com>
Signed-off-by: Chanh Nguyen <chanh@os.amperecomputing.com>
Change-Id: I8c39a2b9c61366d588afd4847833ceb19f24a390
|