summaryrefslogtreecommitdiff
path: root/static/redfish/v1/schema/Cable_v1.xml
blob: b30963309384491f87e44c492c32b90655dffe81 (plain)
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
26
27
28
29
30
31
32
33
34
35
36
37
38
39
40
41
42
43
44
45
46
47
48
49
50
51
52
53
54
55
56
57
58
59
60
61
62
63
64
65
66
67
68
69
70
71
72
73
74
75
76
77
78
79
80
81
82
83
84
85
86
87
88
89
90
91
92
93
94
95
96
97
98
99
100
101
102
103
104
105
106
107
108
109
110
111
112
113
114
115
116
117
118
119
120
121
122
123
124
125
126
127
128
129
130
131
132
133
134
135
136
137
138
139
140
141
142
143
144
145
146
147
148
149
150
151
152
153
154
155
156
157
158
159
160
161
162
163
164
165
166
167
168
169
170
171
172
173
174
175
176
177
178
179
180
181
182
183
184
185
186
187
188
189
190
191
192
193
194
195
196
197
198
199
200
201
202
203
204
205
206
207
208
209
210
211
212
213
214
215
216
217
218
219
220
221
222
223
224
225
226
227
228
229
230
231
232
233
234
235
236
237
238
239
240
241
242
243
244
245
246
247
248
249
250
251
252
253
254
255
256
257
258
259
260
261
262
263
264
265
266
267
268
269
270
271
272
273
274
275
276
277
278
279
280
281
282
283
284
285
286
287
288
289
290
291
292
293
294
295
296
297
298
299
300
301
302
303
304
305
306
307
308
309
310
311
312
313
314
315
316
317
318
319
320
321
322
323
324
325
326
327
328
329
330
331
332
333
334
335
336
337
338
339
340
341
342
343
344
345
346
347
348
349
350
351
352
353
354
355
356
357
358
359
360
361
362
363
364
365
366
367
368
369
370
371
372
373
374
375
376
377
378
379
380
381
382
383
384
385
386
387
388
389
390
391
392
393
394
395
396
397
<?xml version="1.0" encoding="UTF-8"?>
<!---->
<!--################################################################################       -->
<!--# Redfish Schema:  Cable v1.2.0                                                        -->
<!--#                                                                                      -->
<!--# For a detailed change log, see the README file contained in the DSP8010 bundle,      -->
<!--# available at http://www.dmtf.org/standards/redfish                                   -->
<!--# Copyright 2014-2021 DMTF.                                                            -->
<!--# For the full DMTF copyright policy, see http://www.dmtf.org/about/policies/copyright -->
<!--################################################################################       -->
<!---->
<edmx:Edmx xmlns:edmx="http://docs.oasis-open.org/odata/ns/edmx" Version="4.0">

  <edmx:Reference Uri="http://docs.oasis-open.org/odata/odata/v4.0/errata03/csd01/complete/vocabularies/Org.OData.Core.V1.xml">
    <edmx:Include Namespace="Org.OData.Core.V1" Alias="OData"/>
  </edmx:Reference>
  <edmx:Reference Uri="http://docs.oasis-open.org/odata/odata/v4.0/errata03/csd01/complete/vocabularies/Org.OData.Capabilities.V1.xml">
    <edmx:Include Namespace="Org.OData.Capabilities.V1" Alias="Capabilities"/>
  </edmx:Reference>
  <edmx:Reference Uri="http://redfish.dmtf.org/schemas/v1/RedfishExtensions_v1.xml">
    <edmx:Include Namespace="RedfishExtensions.v1_0_0" Alias="Redfish"/>
  </edmx:Reference>
  <edmx:Reference Uri="http://redfish.dmtf.org/schemas/v1/Resource_v1.xml">
    <edmx:Include Namespace="Resource"/>
    <edmx:Include Namespace="Resource.v1_0_0"/>
  </edmx:Reference>
  <edmx:Reference Uri="http://redfish.dmtf.org/schemas/v1/Chassis_v1.xml">
    <edmx:Include Namespace="Chassis"/>
  </edmx:Reference>
  <edmx:Reference Uri="http://redfish.dmtf.org/schemas/v1/Port_v1.xml">
    <edmx:Include Namespace="Port"/>
  </edmx:Reference>
  <edmx:Reference Uri="http://redfish.dmtf.org/schemas/v1/Assembly_v1.xml">
    <edmx:Include Namespace="Assembly"/>
  </edmx:Reference>

  <edmx:DataServices>

    <Schema xmlns="http://docs.oasis-open.org/odata/ns/edm" Namespace="Cable">
      <Annotation Term="Redfish.OwningEntity" String="DMTF"/>

      <EntityType Name="Cable" BaseType="Resource.v1_0_0.Resource" Abstract="true">
        <Annotation Term="OData.AdditionalProperties" Bool="true"/>
        <Annotation Term="OData.Description" String="The Cable schema contains properties that describe a cable connecting endpoints of a chassis, port, or any other cable-compatible endpoint."/>
        <Annotation Term="OData.LongDescription" String="This resource contains a simple cable for a Redfish implementation."/>
        <Annotation Term="Capabilities.InsertRestrictions">
          <Record>
            <PropertyValue Property="Insertable" Bool="false"/>
          </Record>
        </Annotation>
        <Annotation Term="Capabilities.UpdateRestrictions">
          <Record>
            <PropertyValue Property="Updatable" Bool="true"/>
          </Record>
        </Annotation>
        <Annotation Term="Capabilities.DeleteRestrictions">
          <Record>
            <PropertyValue Property="Deletable" Bool="true"/>
          </Record>
        </Annotation>
        <Annotation Term="Redfish.Uris">
          <Collection>
            <String>/redfish/v1/Cables/{CableId}</String>
          </Collection>
        </Annotation>
      </EntityType>
    </Schema>

    <Schema xmlns="http://docs.oasis-open.org/odata/ns/edm" Namespace="Cable.v1_0_0">
      <Annotation Term="Redfish.OwningEntity" String="DMTF"/>
      <Annotation Term="Redfish.Release" String="2021.2"/>

      <EntityType Name="Cable" BaseType="Cable.Cable">
        <Property Name="UserDescription" Type="Edm.String">
          <Annotation Term="OData.Permissions" EnumMember="OData.Permission/ReadWrite"/>
          <Annotation Term="OData.Description" String="The description of this cable."/>
          <Annotation Term="OData.LongDescription" String="This property shall contain a user-defined description for this cable."/>
        </Property>
        <Property Name="CableType" Type="Edm.String">
          <Annotation Term="OData.Permissions" EnumMember="OData.Permission/ReadWrite"/>
          <Annotation Term="OData.Description" String="The type of this cable."/>
          <Annotation Term="OData.LongDescription" String="This property shall contain a user-defined type for this cable."/>
        </Property>
        <Property Name="LengthMeters" Type="Edm.Decimal">
          <Annotation Term="OData.Permissions" EnumMember="OData.Permission/ReadWrite"/>
          <Annotation Term="OData.Description" String="The length of the cable in meters."/>
          <Annotation Term="OData.LongDescription" String="This property shall contain the length of the cable in meters."/>
        </Property>
        <Property Name="DownstreamName" Type="Edm.String">
          <Annotation Term="OData.Permissions" EnumMember="OData.Permission/ReadWrite"/>
          <Annotation Term="OData.Description" String="The identifier for the downstream resource."/>
          <Annotation Term="OData.LongDescription" String="This property shall contain any identifier for a downstream resource."/>
        </Property>
        <Property Name="UpstreamName" Type="Edm.String">
          <Annotation Term="OData.Permissions" EnumMember="OData.Permission/ReadWrite"/>
          <Annotation Term="OData.Description" String="The identifier for the downstream resource."/>
          <Annotation Term="OData.LongDescription" String="This property shall contain any identifier for an upstream resource."/>
        </Property>
        <Property Name="Actions" Type="Cable.v1_0_0.Actions" Nullable="false">
          <Annotation Term="OData.Description" String="The available actions for this resource."/>
          <Annotation Term="OData.LongDescription" String="This property shall contain the available actions for this resource."/>
        </Property>
        <Property Name="Model" Type="Edm.String">
          <Annotation Term="OData.Permissions" EnumMember="OData.Permission/ReadWrite"/>
          <Annotation Term="OData.Description" String="The model number of the cable."/>
          <Annotation Term="OData.LongDescription" String="This property shall contain the name by which the manufacturer generally refers to the cable."/>
        </Property>
        <Property Name="Manufacturer" Type="Edm.String">
          <Annotation Term="OData.Permissions" EnumMember="OData.Permission/ReadWrite"/>
          <Annotation Term="OData.Description" String="The manufacturer of this cable."/>
          <Annotation Term="OData.LongDescription" String="This property shall contain the name of the organization responsible for producing the cable.  This organization might be the entity from whom the cable is purchased, but this is not necessarily true."/>
        </Property>
        <Property Name="Vendor" Type="Edm.String">
          <Annotation Term="OData.Permissions" EnumMember="OData.Permission/ReadWrite"/>
          <Annotation Term="OData.Description" String="The manufacturer of this cable."/>
          <Annotation Term="OData.LongDescription" String="This property shall contain the name of the company that provides the final product that includes this cable."/>
        </Property>
        <Property Name="SKU" Type="Edm.String">
          <Annotation Term="OData.Permissions" EnumMember="OData.Permission/ReadWrite"/>
          <Annotation Term="OData.Description" String="The SKU for this cable."/>
          <Annotation Term="OData.LongDescription" String="This property shall contain the stock-keeping unit (SKU) number for this cable."/>
        </Property>
        <Property Name="SerialNumber" Type="Edm.String">
          <Annotation Term="OData.Permissions" EnumMember="OData.Permission/ReadWrite"/>
          <Annotation Term="OData.Description" String="The serial number for this cable."/>
          <Annotation Term="OData.LongDescription" String="This property shall contain the manufacturer-allocated number that identifies the cable."/>
        </Property>
        <Property Name="PartNumber" Type="Edm.String">
          <Annotation Term="OData.Permissions" EnumMember="OData.Permission/ReadWrite"/>
          <Annotation Term="OData.Description" String="The part number for this cable."/>
          <Annotation Term="OData.LongDescription" String="This property shall contain the part number assigned by the organization that is responsible for producing or manufacturing the cable."/>
        </Property>
        <Property Name="AssetTag" Type="Edm.String">
          <Annotation Term="OData.Permissions" EnumMember="OData.Permission/ReadWrite"/>
          <Annotation Term="OData.Description" String="The user-assigned asset tag for this cable."/>
          <Annotation Term="OData.LongDescription" String="This property shall track the cable for inventory purposes."/>
        </Property>
        <Property Name="CableClass" Type="Cable.v1_0_0.CableClass">
          <Annotation Term="OData.Permissions" EnumMember="OData.Permission/ReadWrite"/>
          <Annotation Term="OData.Description" String="The identifier for the downstream resource."/>
          <Annotation Term="OData.LongDescription" String="The property shall contain the cable class for this cable."/>
        </Property>
        <Property Name="DownstreamConnectorTypes" Type="Collection(Cable.v1_0_0.ConnectorType)" Nullable="false">
          <Annotation Term="OData.Permissions" EnumMember="OData.Permission/ReadWrite"/>
          <Annotation Term="OData.Description" String="The connector types this cable supports."/>
          <Annotation Term="OData.LongDescription" String="The property shall contain an array of connector types this cable supports."/>
        </Property>
        <Property Name="UpstreamConnectorTypes" Type="Collection(Cable.v1_0_0.ConnectorType)" Nullable="false">
          <Annotation Term="OData.Permissions" EnumMember="OData.Permission/ReadWrite"/>
          <Annotation Term="OData.Description" String="The connector types this cable supports."/>
          <Annotation Term="OData.LongDescription" String="The property shall contain an array of connector types this cable supports."/>
        </Property>
        <Property Name="Links" Type="Cable.v1_0_0.Links" Nullable="false">
          <Annotation Term="OData.Description" String="The links to other resources that are related to this resource."/>
          <Annotation Term="OData.LongDescription" String="This property shall contain links to resources that are related to but are not contained by, or subordinate to, this resource."/>
        </Property>
        <Property Name="CableStatus" Type="Cable.v1_0_0.CableStatus" Nullable="false">
          <Annotation Term="OData.Permissions" EnumMember="OData.Permission/ReadWrite"/>
          <Annotation Term="OData.Description" String="The user-reported status of this resource."/>
          <Annotation Term="OData.LongDescription" String="This property shall contain the user-reported status of this resource."/>
        </Property>
        <Property Name="Status" Type="Resource.Status" Nullable="false">
          <Annotation Term="OData.Description" String="The status and health of the resource and its subordinate or dependent resources."/>
          <Annotation Term="OData.LongDescription" String="This property shall contain any status or health properties of the resource."/>
        </Property>
        <Property Name="Location" Type="Resource.Location" Nullable="false">
          <Annotation Term="OData.Description" String="The location of the assembly."/>
          <Annotation Term="OData.LongDescription" String="This property shall contain location information of the associated assembly."/>
        </Property>
        <NavigationProperty Name="Assembly" Type="Assembly.Assembly" ContainsTarget="true" Nullable="false">
          <Annotation Term="OData.Permissions" EnumMember="OData.Permission/Read"/>
          <Annotation Term="OData.Description" String="The link to the assembly associated with this cable."/>
          <Annotation Term="OData.LongDescription" String="This property shall contain a link to a resource of type Assembly."/>
          <Annotation Term="OData.AutoExpandReferences"/>
        </NavigationProperty>
      </EntityType>

      <EnumType Name="CableClass">
        <Member Name="Power">
          <Annotation Term="OData.Description" String="This cable is used for connecting to a power system."/>
        </Member>
        <Member Name="Network">
          <Annotation Term="OData.Description" String="This cable is used for connecting to a networking system."/>
        </Member>
        <Member Name="Storage">
          <Annotation Term="OData.Description" String="This cable is used for connecting to a storage system."/>
        </Member>
        <Member Name="Fan">
          <Annotation Term="OData.Description" String="This cable is used for connecting to a fan system."/>
        </Member>
        <Member Name="PCIe">
          <Annotation Term="OData.Description" String="This cable is used for connecting to a PCIe endpoint."/>
        </Member>
        <Member Name="USB">
          <Annotation Term="OData.Description" String="This cable is used for connecting to a USB endpoint."/>
        </Member>
        <Member Name="Video">
          <Annotation Term="OData.Description" String="This cable is used for connecting to a video system."/>
        </Member>
        <Member Name="Fabric">
          <Annotation Term="OData.Description" String="This cable is used for connecting to a fabric."/>
        </Member>
        <Member Name="Serial">
          <Annotation Term="OData.Description" String="This cable is used for connecting to a serial endpoint."/>
        </Member>
        <Member Name="General">
          <Annotation Term="OData.Description" String="This cable is used for providing general connectivity."/>
        </Member>
      </EnumType>

      <EnumType Name="ConnectorType">
        <Member Name="ACPower">
          <Annotation Term="OData.Description" String="This cable connects to a AC power connector."/>
        </Member>
        <Member Name="DB9">
          <Annotation Term="OData.Description" String="This cable connects to a DB9 connector."/>
        </Member>
        <Member Name="DCPower">
          <Annotation Term="OData.Description" String="This cable connects to a DC power connector."/>
        </Member>
        <Member Name="DisplayPort">
          <Annotation Term="OData.Description" String="This cable connects to a DisplayPort power connector."/>
        </Member>
        <Member Name="HDMI">
          <Annotation Term="OData.Description" String="This cable connects to an HDMI connector."/>
        </Member>
        <Member Name="ICI">
          <Annotation Term="OData.Description" String="This cable connects to an ICI connector."/>
        </Member>
        <Member Name="IPASS">
          <Annotation Term="OData.Description" String="This cable connects to an IPASS connector."/>
        </Member>
        <Member Name="PCIe">
          <Annotation Term="OData.Description" String="This cable connects to a PCIe connector."/>
        </Member>
        <Member Name="Proprietary">
          <Annotation Term="OData.Description" String="This cable connects to a proprietary connector."/>
        </Member>
        <Member Name="RJ45">
          <Annotation Term="OData.Description" String="This cable connects to an RJ45 connector."/>
        </Member>
        <Member Name="SATA">
          <Annotation Term="OData.Description" String="This cable connects to a SATA connector."/>
        </Member>
        <Member Name="SCSI">
          <Annotation Term="OData.Description" String="This cable connects to a SCSI connector."/>
        </Member>
        <Member Name="SlimSAS">
          <Annotation Term="OData.Description" String="This cable connects to a SlimSAS connector."/>
        </Member>
        <Member Name="SFP">
          <Annotation Term="OData.Description" String="This cable connects to a SFP connector."/>
        </Member>
        <Member Name="SFPPlus">
          <Annotation Term="OData.Description" String="This cable connects to a SFPPlus connector."/>
        </Member>
        <Member Name="USBA">
          <Annotation Term="OData.Description" String="This cable connects to a USB-A connector."/>
        </Member>
        <Member Name="USBC">
          <Annotation Term="OData.Description" String="This cable connects to a USB-C connector."/>
        </Member>
        <Member Name="QSFP">
          <Annotation Term="OData.Description" String="This cable connects to a QSFP connector."/>
        </Member>
        <Member Name="CDFP">
          <Annotation Term="OData.Description" String="This cable connects to a CDFP connector."/>
          <Annotation Term="Redfish.Revisions">
            <Collection>
              <Record>
                <PropertyValue Property="Kind" EnumMember="Redfish.RevisionKind/Added"/>
                <PropertyValue Property="Version" String="v1_2_0"/>
              </Record>
            </Collection>
          </Annotation>
        </Member>
        <Member Name="OSFP">
          <Annotation Term="OData.Description" String="This cable connects to a OSFP connector."/>
          <Annotation Term="Redfish.Revisions">
            <Collection>
              <Record>
                <PropertyValue Property="Kind" EnumMember="Redfish.RevisionKind/Added"/>
                <PropertyValue Property="Version" String="v1_2_0"/>
              </Record>
            </Collection>
          </Annotation>
        </Member>
      </EnumType>

      <EnumType Name="CableStatus">
        <Member Name="Normal">
          <Annotation Term="OData.Description" String="The cable is operating normally."/>
          <Annotation Term="OData.LongDescription" String="This value shall indicate the cable is operating normally.  The State property in Status shall contain the value `Enabled` and The Health property in Status shall contain the value `OK`."/>
        </Member>
        <Member Name="Degraded">
          <Annotation Term="OData.Description" String="The cable is degraded."/>
          <Annotation Term="OData.LongDescription" String="This value shall indicate the cable is degraded.  The State property in Status shall contain the value `Enabled` and The Health property in Status shall contain the value `Warning`."/>
        </Member>
        <Member Name="Failed">
          <Annotation Term="OData.Description" String="The cable has failed."/>
          <Annotation Term="OData.LongDescription" String="This value shall indicate the cable has failed.  The State property in Status shall contain the value `Enabled` and The Health property in Status shall contain the value `Critical`."/>
        </Member>
        <Member Name="Testing">
          <Annotation Term="OData.Description" String="The cable is under test."/>
          <Annotation Term="OData.LongDescription" String="This value shall indicate the cable is under test.  The State property in Status shall contain the value `InTest`."/>
        </Member>
        <Member Name="Disabled">
          <Annotation Term="OData.Description" String="The cable is disabled."/>
          <Annotation Term="OData.LongDescription" String="This value shall indicate the cable is disabled.  The State property in Status shall contain the value `Disabled`."/>
        </Member>
        <Member Name="SetByService">
          <Annotation Term="OData.Description" String="The cable status is set by the service."/>
          <Annotation Term="OData.LongDescription" String="This value shall indicate the status for the cable is not defined by the user.  If implemented, the service shall determine the value of the State and Health properties in Status."/>
        </Member>
      </EnumType>

      <ComplexType Name="Actions">
        <Annotation Term="OData.AdditionalProperties" Bool="false"/>
        <Annotation Term="OData.Description" String="The available actions for this resource."/>
        <Annotation Term="OData.LongDescription" String="This type shall contain the available actions for this resource."/>
        <Property Name="Oem" Type="Cable.v1_0_0.OemActions" Nullable="false">
          <Annotation Term="OData.Description" String="The available OEM-specific actions for this resource."/>
          <Annotation Term="OData.LongDescription" String="This property shall contain the available OEM-specific actions for this resource."/>
        </Property>
      </ComplexType>

      <ComplexType Name="OemActions">
        <Annotation Term="OData.AdditionalProperties" Bool="true"/>
        <Annotation Term="OData.Description" String="The available OEM-specific actions for this resource."/>
        <Annotation Term="OData.LongDescription" String="This type shall contain the available OEM-specific actions for this resource."/>
      </ComplexType>

      <ComplexType Name="Links" BaseType="Resource.Links">
        <Annotation Term="OData.Description" String="The links to other resources that are related to this resource."/>
        <Annotation Term="OData.LongDescription" String="This Redfish Specification-described type shall contain links to resources that are related to but are not contained by, or subordinate to, this resource."/>
        <NavigationProperty Name="DownstreamChassis" Type="Collection(Chassis.Chassis)">
          <Annotation Term="OData.Permissions" EnumMember="OData.Permission/ReadWrite"/>
          <Annotation Term="OData.Description" String="An array of links to the downstream chassis connected to this cable."/>
          <Annotation Term="OData.LongDescription" String="This property shall contain an array of links to resources of type Chassis that represent the physical downstream containers connected to this cable."/>
          <Annotation Term="OData.AutoExpandReferences"/>
        </NavigationProperty>
        <NavigationProperty Name="UpstreamChassis" Type="Collection(Chassis.Chassis)">
          <Annotation Term="OData.Permissions" EnumMember="OData.Permission/ReadWrite"/>
          <Annotation Term="OData.Description" String="An array of links to the upstream chassis connected to this cable."/>
          <Annotation Term="OData.LongDescription" String="This property shall contain an array of links to resources of type Chassis that represent the physical upstream containers connected to this cable."/>
          <Annotation Term="OData.AutoExpandReferences"/>
        </NavigationProperty>
        <NavigationProperty Name="DownstreamPorts" Type="Collection(Port.Port)">
          <Annotation Term="OData.Permissions" EnumMember="OData.Permission/ReadWrite"/>
          <Annotation Term="OData.Description" String="An array of links to the downstream ports connected to this cable."/>
          <Annotation Term="OData.LongDescription" String="This property shall contain an array of links to resources of type Port that represent the physical downstream connections connected to this cable."/>
          <Annotation Term="OData.AutoExpandReferences"/>
        </NavigationProperty>
        <NavigationProperty Name="UpstreamPorts" Type="Collection(Port.Port)">
          <Annotation Term="OData.Permissions" EnumMember="OData.Permission/ReadWrite"/>
          <Annotation Term="OData.Description" String="An array of links to the upstream ports connected to this cable."/>
          <Annotation Term="OData.LongDescription" String="This property shall contain an array of links to resources of type Port that represent the physical upstream connections connected to this cable."/>
          <Annotation Term="OData.AutoExpandReferences"/>
        </NavigationProperty>
        <NavigationProperty Name="DownstreamResources" Type="Collection(Resource.Resource)">
          <Annotation Term="OData.Permissions" EnumMember="OData.Permission/ReadWrite"/>
          <Annotation Term="OData.Description" String="An array of links to the downstream resources connected to this cable."/>
          <Annotation Term="OData.LongDescription" String="This property shall contain an array of links to resources that represent the physical downstream connections connected to this cable.  Even if the resource is already referenced in another property within Links, such as DownstreamPorts or DownstreamChassis, it shall also be referenced in this property."/>
          <Annotation Term="OData.AutoExpandReferences"/>
        </NavigationProperty>
        <NavigationProperty Name="UpstreamResources" Type="Collection(Resource.Resource)">
          <Annotation Term="OData.Permissions" EnumMember="OData.Permission/ReadWrite"/>
          <Annotation Term="OData.Description" String="An array of links to the upstream resources connected to this cable."/>
          <Annotation Term="OData.LongDescription" String="This property shall contain an array of links to resources that represent the physical upstream connections connected to this cable.  Even if the resource is already referenced in another property within Links, such as UpstreamPorts or UpstreamChassis, it shall also be referenced in this property."/>
          <Annotation Term="OData.AutoExpandReferences"/>
        </NavigationProperty>
      </ComplexType>
    </Schema>

    <Schema xmlns="http://docs.oasis-open.org/odata/ns/edm" Namespace="Cable.v1_1_0">
      <Annotation Term="Redfish.OwningEntity" String="DMTF"/>
      <Annotation Term="Redfish.Release" String="2021.3"/>

      <EntityType Name="Cable" BaseType="Cable.v1_0_0.Cable">
        <Property Name="UserLabel" Type="Edm.String" Nullable="false">
          <Annotation Term="OData.Permissions" EnumMember="OData.Permission/ReadWrite"/>
          <Annotation Term="OData.Description" String="A user-assigned label."/>
          <Annotation Term="OData.LongDescription" String="This property shall contain a user-assigned label used to identify this resource.  If a value has not been assigned by a user, the value of this property shall be an empty string."/>
        </Property>
      </EntityType>
    </Schema>

    <Schema xmlns="http://docs.oasis-open.org/odata/ns/edm" Namespace="Cable.v1_2_0">
      <Annotation Term="Redfish.OwningEntity" String="DMTF"/>
      <Annotation Term="Redfish.Release" String="2021.4"/>
      <Annotation Term="OData.Description" String="This version was created to add `CDFP` and `OSFP` to ConnectorType."/>

      <EntityType Name="Cable" BaseType="Cable.v1_1_0.Cable"/>
    </Schema>

  </edmx:DataServices>
</edmx:Edmx>