summaryrefslogtreecommitdiff
path: root/static/redfish/v1/schema/Sensor_v1.xml
blob: bdba6c96f27b2c7a4a9c242138b7228d2d662867 (plain)
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
26
27
28
29
30
31
32
33
34
35
36
37
38
39
40
41
42
43
44
45
46
47
48
49
50
51
52
53
54
55
56
57
58
59
60
61
62
63
64
65
66
67
68
69
70
71
72
73
74
75
76
77
78
79
80
81
82
83
84
85
86
87
88
89
90
91
92
93
94
95
96
97
98
99
100
101
102
103
104
105
106
107
108
109
110
111
112
113
114
115
116
117
118
119
120
121
122
123
124
125
126
127
128
129
130
131
132
133
134
135
136
137
138
139
140
141
142
143
144
145
146
147
148
149
150
151
152
153
154
155
156
157
158
159
160
161
162
163
164
165
166
167
168
169
170
171
172
173
174
175
176
177
178
179
180
181
182
183
184
185
186
187
188
189
190
191
192
193
194
195
196
197
198
199
200
201
202
203
204
205
206
207
208
209
210
211
212
213
214
215
216
217
218
219
220
221
222
223
224
225
226
227
228
229
230
231
232
233
234
235
236
237
238
239
240
241
242
243
244
245
246
247
248
249
250
251
252
253
254
255
256
257
258
259
260
261
262
263
264
265
266
267
268
269
270
271
272
273
274
275
276
277
278
279
280
281
282
283
284
285
286
287
288
289
290
291
292
293
294
295
296
297
298
299
300
301
302
303
304
305
306
307
308
309
310
311
312
313
314
315
316
317
318
319
320
321
322
323
324
325
326
327
328
329
330
331
332
333
334
335
336
337
338
339
340
341
342
343
344
345
346
347
348
349
350
351
352
353
354
355
356
357
358
359
360
361
362
363
364
365
366
367
368
369
370
371
372
373
374
375
376
377
378
379
380
381
382
383
384
385
386
387
388
389
390
391
392
393
394
395
396
397
398
399
400
401
402
403
404
405
406
407
408
409
410
411
412
413
414
415
416
417
418
419
420
421
422
423
424
425
426
427
428
429
430
431
432
433
434
435
436
437
438
439
440
441
442
443
444
445
446
447
448
449
450
451
452
453
454
455
456
457
458
459
460
461
462
463
464
465
466
467
468
469
470
471
472
473
474
475
476
477
478
479
480
481
482
483
484
485
486
487
488
489
490
491
492
493
494
495
496
497
498
499
500
501
502
503
504
505
506
507
508
509
510
511
512
513
514
515
516
517
518
519
520
521
522
523
524
525
526
527
528
529
530
531
532
533
534
535
536
537
538
539
540
541
542
543
544
545
546
547
548
549
550
551
552
553
554
555
556
557
558
559
560
561
562
563
564
565
566
567
568
569
570
571
572
573
574
575
576
577
578
579
580
581
582
583
584
585
586
587
588
589
590
<?xml version="1.0" encoding="UTF-8"?>
<!---->
<!--################################################################################       -->
<!--# Redfish Schema:  Sensor v1.1.1                                                       -->
<!--#                                                                                      -->
<!--# For a detailed change log, see the README file contained in the DSP8010 bundle,      -->
<!--# available at http://www.dmtf.org/standards/redfish                                   -->
<!--# Copyright 2014-2020 DMTF.                                                            -->
<!--# For the full DMTF copyright policy, see http://www.dmtf.org/about/policies/copyright -->
<!--################################################################################       -->
<!---->
<edmx:Edmx xmlns:edmx="http://docs.oasis-open.org/odata/ns/edmx" Version="4.0">

  <edmx:Reference Uri="http://docs.oasis-open.org/odata/odata/v4.0/errata03/csd01/complete/vocabularies/Org.OData.Core.V1.xml">
    <edmx:Include Namespace="Org.OData.Core.V1" Alias="OData"/>
  </edmx:Reference>
  <edmx:Reference Uri="http://docs.oasis-open.org/odata/odata/v4.0/errata03/csd01/complete/vocabularies/Org.OData.Capabilities.V1.xml">
    <edmx:Include Namespace="Org.OData.Capabilities.V1" Alias="Capabilities"/>
  </edmx:Reference>
  <edmx:Reference Uri="http://docs.oasis-open.org/odata/odata/v4.0/errata03/csd01/complete/vocabularies/Org.OData.Measures.V1.xml">
    <edmx:Include Namespace="Org.OData.Measures.V1" Alias="Measures"/>
  </edmx:Reference>
  <edmx:Reference Uri="http://redfish.dmtf.org/schemas/v1/RedfishExtensions_v1.xml">
    <edmx:Include Namespace="RedfishExtensions.v1_0_0" Alias="Redfish"/>
    <edmx:Include Namespace="Validation.v1_0_0" Alias="Validation"/>
  </edmx:Reference>
  <edmx:Reference Uri="http://redfish.dmtf.org/schemas/v1/Resource_v1.xml">
    <edmx:Include Namespace="Resource"/>
    <edmx:Include Namespace="Resource.v1_0_0"/>
  </edmx:Reference>
  <edmx:Reference Uri="http://redfish.dmtf.org/schemas/v1/PhysicalContext_v1.xml">
    <edmx:Include Namespace="PhysicalContext"/>
  </edmx:Reference>

  <edmx:DataServices>

    <Schema xmlns="http://docs.oasis-open.org/odata/ns/edm" Namespace="Sensor">
      <Annotation Term="Redfish.OwningEntity" String="DMTF"/>

      <EntityType Name="Sensor" BaseType="Resource.v1_0_0.Resource" Abstract="true">
        <Annotation Term="OData.Description" String="The Sensor schema describes a sensor and its properties."/>
        <Annotation Term="OData.LongDescription" String="This resource shall represent a sensor for a Redfish implementation."/>
        <Annotation Term="Capabilities.InsertRestrictions">
          <Record>
            <PropertyValue Property="Insertable" Bool="false"/>
          </Record>
        </Annotation>
        <Annotation Term="Capabilities.UpdateRestrictions">
          <Record>
            <PropertyValue Property="Updatable" Bool="true"/>
            <Annotation Term="OData.Description" String="Any writable properties, such as limits and exceptions, can be updated for sensors."/>
          </Record>
        </Annotation>
        <Annotation Term="Capabilities.DeleteRestrictions">
          <Record>
            <PropertyValue Property="Deletable" Bool="false"/>
          </Record>
        </Annotation>
        <Annotation Term="Redfish.Uris">
          <Collection>
            <String>/redfish/v1/Chassis/{ChassisId}/Sensors/{SensorId}</String>
            <String>/redfish/v1/PowerEquipment/Sensors/{SensorId}</String>
            <String>/redfish/v1/PowerEquipment/RackPDUs/{PowerDistributionId}/Sensors/{SensorId}</String>
            <String>/redfish/v1/PowerEquipment/FloorPDUs/{PowerDistributionId}/Sensors/{SensorId}</String>
            <String>/redfish/v1/PowerEquipment/TransferSwitches/{PowerDistributionId}/Sensors/{SensorId}</String>
          </Collection>
        </Annotation>
      </EntityType>

      <Action Name="ResetMetrics" IsBound="true">
        <Annotation Term="OData.Description" String="Resets metrics related to this sensor."/>
        <Annotation Term="OData.LongDescription" String="This action shall reset any time intervals or counted values for this sensor.  The SensorResetTime property shall be updated to reflect the time that this action was performed."/>
        <Parameter Name="Sensor" Type="Sensor.v1_0_0.Actions"/>
      </Action>

      <EnumType Name="VoltageType">
        <Member Name="AC">
          <Annotation Term="OData.Description" String="Alternating current."/>
        </Member>
        <Member Name="DC">
          <Annotation Term="OData.Description" String="Direct current."/>
        </Member>
      </EnumType>

      <EnumType Name="ElectricalContext">
        <Member Name="Line1">
          <Annotation Term="OData.Description" String="The circuits that share the L1 current-carrying conductor."/>
          <Annotation Term="OData.LongDescription" String="This value shall represent a circuit that shares the L1 current-carrying conductor, such as circuits with phase wiring types of Two-phase / 3-Wire or 4-Wire, or Three-phase / 4-Wire or 5-Wire."/>
        </Member>
        <Member Name="Line2">
          <Annotation Term="OData.Description" String="The circuits that share the L2 current-carrying conductor."/>
          <Annotation Term="OData.LongDescription" String="This value shall represent a circuit that shares the L2 current-carrying conductor, such as circuits with phase wiring types of Two-phase / 4-Wire or Three-phase / 4-Wire or 5-Wire."/>
        </Member>
        <Member Name="Line3">
          <Annotation Term="OData.Description" String="The circuits that share the L3 current-carrying conductor."/>
          <Annotation Term="OData.LongDescription" String="This value shall represent a circuit that shares the L3 current-carrying conductor, such as circuits with phase wiring types of Three-phase / 4-Wire or 5-Wire."/>
        </Member>
        <Member Name="Neutral">
          <Annotation Term="OData.Description" String="The grounded current-carrying return circuit of current-carrying conductors."/>
          <Annotation Term="OData.LongDescription" String="This value shall represent the grounded current-carrying return circuit of current-carrying conductors, such as circuits with phase wiring types of Single-phase / 3-Wire, Two-phase / 4-Wire, or Three-phase / 5-Wire."/>
        </Member>
        <Member Name="LineToLine">
          <Annotation Term="OData.Description" String="The circuit formed by two current-carrying conductors."/>
          <Annotation Term="OData.LongDescription" String="This value shall represent a circuit formed by two current-carrying conductors, such as circuits with phase wiring types of Two-phase / 3-Wire or 4-Wire, or Three-phase / 4-Wire or 5-Wire."/>
        </Member>
        <Member Name="Line1ToLine2">
          <Annotation Term="OData.Description" String="The circuit formed by L1 and L2 current-carrying conductors."/>
          <Annotation Term="OData.LongDescription" String="This value shall represent a circuit formed by L1 and L2 current-carrying conductors, such as circuits with phase wiring types of Two-phase / 3-Wire or 4-Wire, or Three-phase / 4-Wire or 5-Wire."/>
        </Member>
        <Member Name="Line2ToLine3">
          <Annotation Term="OData.Description" String="The circuit formed by L2 and L3 current-carrying conductors."/>
          <Annotation Term="OData.LongDescription" String="This value shall represent a circuit formed by L2 and L3 current-carrying conductors, such as circuits with phase wiring types of Three-phase / 4-Wire or 5-Wire."/>
        </Member>
        <Member Name="Line3ToLine1">
          <Annotation Term="OData.Description" String="The circuit formed by L3 and L1 current-carrying conductors."/>
          <Annotation Term="OData.LongDescription" String="This value shall represent a circuit formed by L3 and L1 current-carrying conductors, such as circuits with phase wiring types of Three-phase / 4-Wire or 5-Wire."/>
        </Member>
        <Member Name="LineToNeutral">
          <Annotation Term="OData.Description" String="The circuit formed by a line and neutral current-carrying conductor."/>
          <Annotation Term="OData.LongDescription" String="This value shall represent a circuit formed by a line and neutral current-carrying conductor, such as circuits with phase wiring types of Single-phase / 3-Wire, Two-phase / 4-Wire, or Three-phase / 4-Wire or 5-Wire."/>
        </Member>
        <Member Name="Line1ToNeutral">
          <Annotation Term="OData.Description" String="The circuit formed by L1 and neutral current-carrying conductors."/>
          <Annotation Term="OData.LongDescription" String="This value shall represent a circuit formed by L1 and neutral current-carrying conductors, such as circuits with phase wiring types of Single-pase / 3-Wire, Two-phase / 3-Wire or 4-Wire, or Three-phase / 4-Wire or 5-Wire."/>
        </Member>
        <Member Name="Line2ToNeutral">
          <Annotation Term="OData.Description" String="The circuit formed by L2 and neutral current-carrying conductors."/>
          <Annotation Term="OData.LongDescription" String="This value shall represent a circuit formed by L2 and neutral current-carrying conductors, such as circuits with phase wiring types of Two-phase / 4-Wire or Three-phase / 5-Wire."/>
        </Member>
        <Member Name="Line3ToNeutral">
          <Annotation Term="OData.Description" String="The circuit formed by L3 and neutral current-carrying conductors."/>
          <Annotation Term="OData.LongDescription" String="This value shall represent a circuit formed by L3 and neutral current-carrying conductors, such as circuits with a phase wiring type of Three-phase / 5-Wire."/>
        </Member>
         <Member Name="Line1ToNeutralAndL1L2">
          <Annotation Term="OData.Description" String="The circuit formed by L1, L2, and neutral current-carrying conductors."/>
          <Annotation Term="OData.LongDescription" String="This value shall represent circuit formed by L1, L2, and neutral current-carrying conductors, such as circuits with phase wiring types of Two-phase/ 4-Wire or Three-phase / 5-Wire."/>
        </Member>
        <Member Name="Line2ToNeutralAndL1L2">
          <Annotation Term="OData.Description" String="The circuit formed by L1, L2, and Neutral current-carrying conductors."/>
          <Annotation Term="OData.LongDescription" String="This value shall represent a circuit formed by L1, L2, and neutral current-carrying conductors, such as circuits with phase wiring types of Two-phase/ 4-Wire or Three-phase / 5-Wire."/>
        </Member>
        <Member Name="Line2ToNeutralAndL2L3">
          <Annotation Term="OData.Description" String="The circuits formed by L2, L3, and neutral current-carrying conductors."/>
          <Annotation Term="OData.LongDescription" String="This value shall represent a circuit formed by L2, L3, and neutral current-carrying conductors, such as circuits with a phase wiring type of Three-phase / 5-Wire."/>
        </Member>
        <Member Name="Line3ToNeutralAndL3L1">
          <Annotation Term="OData.Description" String="The circuit formed by L3, L1, and neutral current-carrying conductors."/>
          <Annotation Term="OData.LongDescription" String="This value shall represent a circuit formed by L3, L1, and neutral current-carrying conductors, such as circuits with a phase wiring type of Three-phase / 5-Wire."/>
        </Member>
        <Member Name="Total">
          <Annotation Term="OData.Description" String="The circuit formed by all current-carrying conductors."/>
          <Annotation Term="OData.LongDescription" String="This value shall represent the circuits formed by all current-carrying conductors for any phase wiring type."/>
        </Member>
      </EnumType>
    </Schema>

    <Schema xmlns="http://docs.oasis-open.org/odata/ns/edm" Namespace="Sensor.v1_0_0">
      <Annotation Term="Redfish.OwningEntity" String="DMTF"/>
      <Annotation Term="Redfish.Release" String="2018.3"/>

      <EntityType Name="Sensor" BaseType="Sensor.Sensor">
        <Property Name="ReadingType" Type="Sensor.v1_0_0.ReadingType">
          <Annotation Term="OData.Permissions" EnumMember="OData.Permission/Read"/>
          <Annotation Term="OData.Description" String="The type of sensor."/>
          <Annotation Term="OData.LongDescription" String="This property shall contain the type of the sensor."/>
        </Property>
        <Property Name="DataSourceUri" Type="Edm.String">
          <Annotation Term="OData.Permissions" EnumMember="OData.Permission/Read"/>
          <Annotation Term="OData.Description" String="The link to the resource that provides the data for this sensor."/>
          <Annotation Term="OData.LongDescription" String="This property shall contain a URI to the resource that provides the source of the excerpt contained within this copy."/>
          <Annotation Term="OData.IsURL"/>
          <Annotation Term="Redfish.ExcerptCopyOnly"/>
        </Property>

        <Property Name="Status" Type="Resource.Status" Nullable="false">
          <Annotation Term="OData.Description" String="The status and health of the resource and its subordinate or dependent resources."/>
          <Annotation Term="OData.LongDescription" String="This property shall contain any status or health properties of the resource."/>
        </Property>

        <Property Name="Reading" Type="Edm.Decimal">
          <Annotation Term="OData.Permissions" EnumMember="OData.Permission/Read"/>
          <Annotation Term="OData.Description" String="The sensor value."/>
          <Annotation Term="OData.LongDescription" String="This property shall contain the sensor value."/>
          <Annotation Term="Redfish.Excerpt"/>
        </Property>
        <Property Name="ReadingUnits" Type="Edm.String">
          <Annotation Term="OData.Permissions" EnumMember="OData.Permission/Read"/>
          <Annotation Term="OData.Description" String="The units of the reading and thresholds."/>
          <Annotation Term="OData.LongDescription" String="This property shall contain the units of the sensor's reading and thresholds."/>
        </Property>
        <Property Name="PhysicalContext" Type="PhysicalContext.PhysicalContext">
          <Annotation Term="OData.Permissions" EnumMember="OData.Permission/Read"/>
          <Annotation Term="OData.Description" String="The area or device to which this sensor measurement applies."/>
          <Annotation Term="OData.LongDescription" String="This property shall contain a description of the affected component or region within the equipment to which this sensor measurement applies."/>
          <Annotation Term="Redfish.Excerpt" String="Array"/>
        </Property>
        <Property Name="PhysicalSubContext" Type="PhysicalContext.PhysicalSubContext">
          <Annotation Term="OData.Permissions" EnumMember="OData.Permission/Read"/>
          <Annotation Term="OData.Description" String="The usage or location within a device to which this sensor measurement applies."/>
          <Annotation Term="OData.LongDescription" String="This property shall contain a description of the usage or sub-region within the equipment to which this sensor measurement applies.  This property generally differentiates multiple sensors within the same PhysicalContext instance."/>
          <Annotation Term="Redfish.Excerpt" String="Array"/>
        </Property>
        <Property Name="PeakReading" Type="Edm.Decimal">
          <Annotation Term="OData.Permissions" EnumMember="OData.Permission/Read"/>
          <Annotation Term="OData.Description" String="The peak sensor value."/>
          <Annotation Term="OData.LongDescription" String="This property shall contain the peak sensor value since the last ResetStatistics action was performed or the service last reset the time-based property values."/>
        </Property>

        <Property Name="MaxAllowableOperatingValue" Type="Edm.Decimal">
          <Annotation Term="OData.Permissions" EnumMember="OData.Permission/Read"/>
          <Annotation Term="OData.Description" String="The maximum allowable operating value for this equipment."/>
          <Annotation Term="OData.LongDescription" String="This property shall contain the maximum allowable operating value for the equipment that this sensor monitors, as specified by a standards body, manufacturer, or both."/>
        </Property>
        <Property Name="MinAllowableOperatingValue" Type="Edm.Decimal">
          <Annotation Term="OData.Permissions" EnumMember="OData.Permission/Read"/>
          <Annotation Term="OData.Description" String="The minimum allowable operating value for this equipment."/>
          <Annotation Term="OData.LongDescription" String="This property shall contain the minimum allowable operating value for the equipment that this sensor monitors, as specified by a standards body, manufacturer, or both."/>
        </Property>
        <Property Name="AdjustedMaxAllowableOperatingValue" Type="Edm.Decimal">
          <Annotation Term="OData.Permissions" EnumMember="OData.Permission/Read"/>
          <Annotation Term="OData.Description" String="The adjusted maximum allowable operating value for this equipment based on the environmental conditions."/>
          <Annotation Term="OData.LongDescription" String="This property shall contain the adjusted maximum allowable operating value for the equipment that this sensor monitors, as specified by a standards body, manufacturer, or both.  The value is adjusted based on environmental conditions.  For example, liquid inlet temperature can be adjusted based on the available liquid pressure."/>
        </Property>
        <Property Name="AdjustedMinAllowableOperatingValue" Type="Edm.Decimal">
          <Annotation Term="OData.Permissions" EnumMember="OData.Permission/Read"/>
          <Annotation Term="OData.Description" String="The adjusted minimum allowable operating value for this equipment based on the environmental conditions."/>
          <Annotation Term="OData.LongDescription" String="This property shall contain the adjusted minimum allowable operating value for the equipment that this sensor monitors, as specified by a standards body, manufacturer, or both.  This value is adjusted based on environmental conditions.  For example, liquid inlet temperature can be adjusted based on the available liquid pressure."/>
        </Property>

        <Property Name="ApparentVA" Type="Edm.Decimal">
          <Annotation Term="OData.Permissions" EnumMember="OData.Permission/Read"/>
          <Annotation Term="OData.Description" String="The product of voltage and current for an AC circuit, in Volt-Ampere units."/>
          <Annotation Term="OData.LongDescription" String="This property shall contain the product of VoltageRMS multiplied by CurrentRMS for a circuit.  This property can appear in sensors of the Power ReadingType, and shall not appear in sensors of other ReadingType values."/>
          <Annotation Term="Measures.Unit" String="V.A"/>
          <Annotation Term="Redfish.Excerpt" String="Power"/>
        </Property>
        <Property Name="ReactiveVAR" Type="Edm.Decimal">
          <Annotation Term="OData.Permissions" EnumMember="OData.Permission/Read"/>
          <Annotation Term="OData.Description" String="The square root of the difference term of squared ApparentVA and squared Power (Reading) for a circuit, in var units."/>
          <Annotation Term="OData.LongDescription" String="This property shall contain the arithmetic mean of product terms of instantaneous voltage and quadrature current measurements calculated over an integer number of line cycles for a circuit.  This property can appear in sensors of the Power ReadingType, and shall not appear in sensors of other ReadingType values."/>
          <Annotation Term="Measures.Unit" String="V.A"/>
          <Annotation Term="Redfish.Excerpt" String="Power"/>
        </Property>
        <Property Name="PowerFactor" Type="Edm.Decimal">
          <Annotation Term="OData.Permissions" EnumMember="OData.Permission/Read"/>
          <Annotation Term="OData.Description" String="The power factor for this sensor."/>
          <Annotation Term="OData.LongDescription" String="This property shall identify the quotient of PowerRealWatts and PowerApparentVA for a circuit.  PowerFactor is expressed in unit-less 1/100ths.  This property can appear in sensors of the Power ReadingType, and shall not appear in sensors of other ReadingType values."/>
          <Annotation Term="Validation.Minimum" Int="0"/>
          <Annotation Term="Validation.Maximum" Int="1"/>
          <Annotation Term="Redfish.Excerpt" String="Power"/>
        </Property>
        <Property Name="LoadPercent" Type="Edm.Decimal">
          <Annotation Term="OData.Permissions" EnumMember="OData.Permission/Read"/>
          <Annotation Term="OData.Description" String="The power load utilization for this sensor."/>
          <Annotation Term="OData.LongDescription" String="This property shall indicate the power load utilization percent for this sensor.  This property can appear in sensors of the Power ReadingType, and shall not appear in sensors of other ReadingType values."/>
          <Annotation Term="Measures.Unit" String="%"/>
          <Annotation Term="Redfish.Revisions">
            <Collection>
              <Record>
                <PropertyValue Property="Kind" EnumMember="Redfish.RevisionKind/Deprecated"/>
                <PropertyValue Property="Version" String="v1_1_0"/>
                <PropertyValue Property="Description" String="This property has been deprecated in favor of using a sensor instance with a ReadingType of `Percent` to show utilization values when needed."/>
              </Record>
            </Collection>
          </Annotation>
        </Property>

        <Property Name="Location" Type="Resource.Location" Nullable="false">
          <Annotation Term="OData.Description" String="The location information for this sensor."/>
          <Annotation Term="OData.LongDescription" String="This property shall indicate the location information for this sensor."/>
        </Property>
        <Property Name="ElectricalContext" Type="Sensor.ElectricalContext">
          <Annotation Term="OData.Permissions" EnumMember="OData.Permission/Read"/>
          <Annotation Term="OData.Description" String="The combination of current-carrying conductors."/>
          <Annotation Term="OData.LongDescription" String="This property shall represent the combination of current-carrying conductors that distribute power."/>
        </Property>
        <Property Name="VoltageType" Type="Sensor.VoltageType">
          <Annotation Term="OData.Permissions" EnumMember="OData.Permission/Read"/>
          <Annotation Term="OData.Description" String="The voltage type for this sensor."/>
          <Annotation Term="OData.LongDescription" String="This property shall represent the type of input voltage the sensor monitors."/>
        </Property>

        <Property Name="Thresholds" Type="Sensor.v1_0_0.Thresholds" Nullable="false">
          <Annotation Term="OData.Description" String="The set of thresholds defined for this sensor."/>
          <Annotation Term="OData.LongDescription" String="This property shall contain the set of thresholds that derive a sensor's health and operational range."/>
        </Property>

        <Property Name="ReadingRangeMax" Type="Edm.Decimal">
          <Annotation Term="OData.Permissions" EnumMember="OData.Permission/Read"/>
          <Annotation Term="OData.Description" String="The maximum possible value for this sensor."/>
          <Annotation Term="OData.LongDescription" String="This property shall indicate the maximum possible value of the Reading property for this sensor.  This value is the range of valid readings for this sensor.  Values outside this range are discarded as reading errors."/>
        </Property>
        <Property Name="ReadingRangeMin" Type="Edm.Decimal">
          <Annotation Term="OData.Permissions" EnumMember="OData.Permission/Read"/>
          <Annotation Term="OData.Description" String="The minimum possible value for this sensor."/>
          <Annotation Term="OData.LongDescription" String="This property shall indicate the minimum possible value of the Reading property for this sensor.  This value is the range of valid readings for this sensor.  Values outside this range are discarded as reading errors."/>
        </Property>
        <Property Name="Precision" Type="Edm.Decimal">
          <Annotation Term="OData.Permissions" EnumMember="OData.Permission/Read"/>
          <Annotation Term="OData.Description" String="The number of significant digits in the reading."/>
          <Annotation Term="OData.LongDescription" String="This property shall contain the number of significant digits in the Reading property."/>
        </Property>
        <Property Name="Accuracy" Type="Edm.Decimal">
          <Annotation Term="OData.Permissions" EnumMember="OData.Permission/Read"/>
          <Annotation Term="OData.Description" String="The estimated percent error of measured versus actual values."/>
          <Annotation Term="OData.LongDescription" String="This property shall contain the percent error +/- of the measured versus actual values of the Reading property."/>
          <Annotation Term="Measures.Unit" String="%"/>
        </Property>
        <Property Name="SensingFrequency" Type="Edm.Decimal">
          <Annotation Term="OData.Permissions" EnumMember="OData.Permission/Read"/>
          <Annotation Term="OData.Description" String="The time interval between readings of the physical sensor."/>
          <Annotation Term="OData.LongDescription" String="This property shall contain the time interval between readings of the physical sensor."/>
          <Annotation Term="Redfish.Revisions">
            <Collection>
              <Record>
                <PropertyValue Property="Kind" EnumMember="Redfish.RevisionKind/Deprecated"/>
                <PropertyValue Property="Version" String="v1_1_0"/>
                <PropertyValue Property="Description" String="This property has been deprecated in favor of the SensingInterval property, which uses the duration time format for interoperability."/>
              </Record>
            </Collection>
          </Annotation>
        </Property>
        <Property Name="PeakReadingTime" Type="Edm.DateTimeOffset">
          <Annotation Term="OData.Permissions" EnumMember="OData.Permission/Read"/>
          <Annotation Term="OData.Description" String="The time when the peak sensor value occurred."/>
          <Annotation Term="OData.LongDescription" String="This property shall contain the date and time when the peak sensor value was observed."/>
        </Property>
        <Property Name="SensorResetTime" Type="Edm.DateTimeOffset">
          <Annotation Term="OData.Permissions" EnumMember="OData.Permission/Read"/>
          <Annotation Term="OData.Description" String="The date and time when the time-based properties were last reset."/>
          <Annotation Term="OData.LongDescription" String="This property shall contain the date and time when the ResetStatistics action was last performed or the service last reset the time-based property values."/>
          <Annotation Term="Redfish.Excerpt" String="EnergykWh"/>
        </Property>

        <Property Name="Actions" Type="Sensor.v1_0_0.Actions" Nullable="false">
          <Annotation Term="OData.Description" String="The available actions for this resource."/>
          <Annotation Term="OData.LongDescription" String="This property shall contain the available actions for this resource."/>
        </Property>
      </EntityType>

      <ComplexType Name="Thresholds">
        <Annotation Term="OData.AdditionalProperties" Bool="false"/>
        <Annotation Term="OData.Description" String="The set of thresholds defined for a sensor."/>
        <Annotation Term="OData.LongDescription" String="This object shall contain the set of thresholds that derive a sensor's health and operational range."/>
        <Property Name="UpperCaution" Type="Sensor.v1_0_0.Threshold" Nullable="false">
          <Annotation Term="OData.Description" String="The value at which the reading is above normal range."/>
          <Annotation Term="OData.LongDescription" String="This property shall contain the value at which the Reading property is above the normal range.  The value of the property shall use the same units as the Reading property."/>
        </Property>
        <Property Name="UpperCritical" Type="Sensor.v1_0_0.Threshold" Nullable="false">
          <Annotation Term="OData.Description" String="The value at which the reading is above normal range but not yet fatal."/>
          <Annotation Term="OData.LongDescription" String="This property shall contain the value at which the Reading property is above the normal range but is not yet fatal.  The value of the property shall use the same units as the Reading property."/>
        </Property>
        <Property Name="UpperFatal" Type="Sensor.v1_0_0.Threshold" Nullable="false">
          <Annotation Term="OData.Description" String="The value at which the reading is above normal range and fatal."/>
          <Annotation Term="OData.LongDescription" String="This property shall contain the value at which the Reading property is above the normal range and is fatal.  The value of the property shall use the same units as the Reading property."/>
        </Property>
        <Property Name="LowerCaution" Type="Sensor.v1_0_0.Threshold" Nullable="false">
          <Annotation Term="OData.Description" String="The value at which the reading is below normal range."/>
          <Annotation Term="OData.LongDescription" String="This property shall contain the value at which the Reading property is below normal range.  The value of the property shall use the same units as the Reading property."/>
        </Property>
        <Property Name="LowerCritical" Type="Sensor.v1_0_0.Threshold" Nullable="false">
          <Annotation Term="OData.Description" String="The value at which the reading is below normal range but not yet fatal."/>
          <Annotation Term="OData.LongDescription" String="This property shall contain the value at which the Reading property is below the normal range but is not yet fatal.  The value of the property shall use the same units as the Reading property."/>
        </Property>
        <Property Name="LowerFatal" Type="Sensor.v1_0_0.Threshold" Nullable="false">
          <Annotation Term="OData.Description" String="The value at which the reading is below normal range and fatal."/>
          <Annotation Term="OData.LongDescription" String="This property shall contain the value at which the Reading property is below the normal range and is fatal.  The value of the property shall use the same units as the Reading property."/>
        </Property>
      </ComplexType>

      <ComplexType Name="Threshold">
        <Annotation Term="OData.AdditionalProperties" Bool="false"/>
        <Annotation Term="OData.Description" String="The threshold definition for a sensor."/>
        <Annotation Term="OData.LongDescription" String="This type shall contain the properties for an individual threshold for this sensor."/>
        <Property Name="Reading" Type="Edm.Decimal">
          <Annotation Term="OData.Permissions" EnumMember="OData.Permission/ReadWrite"/>
          <Annotation Term="OData.Description" String="The threshold value."/>
          <Annotation Term="OData.LongDescription" String="This property shall indicate the reading for this sensor that activates the threshold.  The value of the property shall use the same units as the Reading property."/>
        </Property>
        <Property Name="Activation" Type="Sensor.v1_0_0.ThresholdActivation">
          <Annotation Term="OData.Permissions" EnumMember="OData.Permission/ReadWrite"/>
          <Annotation Term="OData.Description" String="The direction of crossing that activates this threshold."/>
          <Annotation Term="OData.LongDescription" String="This property shall indicate the direction of crossing of the reading for this sensor that activates the threshold."/>
        </Property>
        <Property Name="DwellTime" Type="Edm.Duration">
          <Annotation Term="OData.Permissions" EnumMember="OData.Permission/ReadWrite"/>
          <Annotation Term="OData.Description" String="The duration the sensor value must violate the threshold before the threshold is activated."/>
          <Annotation Term="OData.LongDescription" String="This property shall indicate the duration the sensor value must violate the threshold before the threshold is activated."/>
        </Property>
      </ComplexType>

      <ComplexType Name="Actions">
        <Annotation Term="OData.AdditionalProperties" Bool="false"/>
        <Annotation Term="OData.Description" String="The available actions for this resource."/>
        <Annotation Term="OData.LongDescription" String="This type shall contain the available actions for this resource."/>
        <Property Name="Oem" Type="Sensor.v1_0_0.OemActions" Nullable="false">
          <Annotation Term="OData.Description" String="The available OEM-specific actions for this resource."/>
          <Annotation Term="OData.LongDescription" String="This property shall contain the available OEM-specific actions for this resource."/>
        </Property>
      </ComplexType>

      <ComplexType Name="OemActions">
        <Annotation Term="OData.AdditionalProperties" Bool="true"/>
        <Annotation Term="OData.Description" String="The available OEM-specific actions for this resource."/>
        <Annotation Term="OData.LongDescription" String="This type shall contain the available OEM-specific actions for this resource."/>
      </ComplexType>

      <EnumType Name="ThresholdActivation">
        <Member Name="Increasing">
          <Annotation Term="OData.Description" String="Value increases above the threshold."/>
          <Annotation Term="OData.LongDescription" String="This threshold is activated when the reading changes from a value lower than the threshold to a value higher than the threshold."/>
        </Member>
        <Member Name="Decreasing">
          <Annotation Term="OData.Description" String="Value decreases below the threshold."/>
          <Annotation Term="OData.LongDescription" String="This threshold is activated when the reading changes from a value higher than the threshold to a value lower than the threshold."/>
        </Member>
        <Member Name="Either">
          <Annotation Term="OData.Description" String="Value crosses the threshold in either direction."/>
          <Annotation Term="OData.LongDescription" String="This threshold is activated when either the increasing or decreasing conditions are met."/>
        </Member>
      </EnumType>

      <EnumType Name="ReadingType">
        <Member Name="Temperature">
          <Annotation Term="OData.Description" String="Temperature."/>
          <Annotation Term="OData.LongDescription" String="This value shall indicate a temperature measurement, in degrees Celsius units, and the ReadingUnits value shall be 'Cel'."/>
        </Member>
        <Member Name="Humidity">
          <Annotation Term="OData.Description" String="Relative Humidity."/>
          <Annotation Term="OData.LongDescription" String="This value shall indicate a relative humidity measurement, in percent units, and the ReadingUnits value shall be '%'."/>
        </Member>
        <Member Name="Power">
          <Annotation Term="OData.Description" String="Power."/>
          <Annotation Term="OData.LongDescription" String="This value shall indicate the arithmetic mean of product terms of instantaneous voltage and current values measured over integer number of line cycles for a circuit, in Watt units, and the ReadingUnits value shall be 'W'."/>
        </Member>
        <Member Name="EnergykWh">
          <Annotation Term="OData.Description" String="Energy (kWh)."/>
          <Annotation Term="OData.LongDescription" String="This value shall indicate the energy, integral of real power over time, of the monitored item since the sensor metrics were last reset.  The value of the Reading property shall be in kilowatt-hour units and the ReadingUnits value shall be `kW.h`.  This value is used for large-scale energy consumption measurements, while EnergyJoules is used for device-level consumption measurements."/>
        </Member>
        <Member Name="EnergyJoules">
          <Annotation Term="OData.Description" String="Energy (Joules)."/>
          <Annotation Term="OData.LongDescription" String="This value shall indicate the energy, integral of real power over time, of the monitored item since the sensor metrics were last reset.  The value of the Reading property shall be in Joule units and the ReadingUnits value shall be `J`.  This value is used for device-level energy consumption measurements, while EnergykWh is used for large-scale consumption measurements."/>
        </Member>
        <Member Name="Voltage">
          <Annotation Term="OData.Description" String="Voltage (AC or DC)."/>
          <Annotation Term="OData.LongDescription" String="This value shall indicate a measurement of the root mean square (RMS) of instantaneous voltage calculated over an integer number of line cycles for a circuit.  Voltage is expressed in Volts units and the ReadingUnits value shall be `V`."/>
        </Member>
        <Member Name="Current">
          <Annotation Term="OData.Description" String="Current."/>
          <Annotation Term="OData.LongDescription" String="This value shall indicate a measurement of the root mean square (RMS) of instantaneous current calculated over an integer number of line cycles for a circuit.  Current is expressed in Amperes units and the ReadingUnits value shall be `A`."/>
        </Member>
        <Member Name="Frequency">
          <Annotation Term="OData.Description" String="Frequency."/>
          <Annotation Term="OData.LongDescription" String="This value shall indicate a frequency measurement, in Hertz units, and the ReadingUnits value shall be `Hz`."/>
        </Member>
        <Member Name="Pressure">
          <Annotation Term="OData.Description" String="Pressure."/>
          <Annotation Term="OData.LongDescription" String="This value shall indicate a measurement of force applied perpendicular to the surface of an object per unit area over which that force is distributed.  The ReadingUnits shall be `Pa`."/>
        </Member>
        <Member Name="LiquidLevel">
          <Annotation Term="OData.Description" String="Liquid level."/>
          <Annotation Term="OData.LongDescription" String="This value shall indicate a measurement of fluid height relative to a specified vertical datum and the ReadingUnits value shall be `cm`."/>
        </Member>
        <Member Name="Rotational">
          <Annotation Term="OData.Description" String="Rotational."/>
          <Annotation Term="OData.LongDescription" String="This value shall indicate a measurement of rotational frequency, in revolutions per minute unit, and the ReadingUnits value shall be `RPM`."/>
        </Member>
        <Member Name="AirFlow">
          <Annotation Term="OData.Description" String="Airflow."/>
          <Annotation Term="OData.LongDescription" String="This value shall indicate a measurement of a volume of gas per unit of time that flows through a particular junction.  The ReadingUnits shall be `cft_i/min`."/>
        </Member>
        <Member Name="LiquidFlow">
          <Annotation Term="OData.Description" String="Liquid flow."/>
          <Annotation Term="OData.LongDescription" String="This value shall indicate a measurement of a volume of liquid per unit of time that flows through a particular junction.  The ReadingUnits shall be `L/s`."/>
        </Member>
        <Member Name="Barometric">
          <Annotation Term="OData.Description" String="Barometric pressure."/>
          <Annotation Term="OData.LongDescription" String="This value shall indicate a measurement of barometric pressure, in millimeters, of a mercury column, and the ReadingUnits value shall be `mm[Hg]`."/>
        </Member>
        <Member Name="Altitude">
          <Annotation Term="OData.Description" String="Altitude."/>
          <Annotation Term="OData.LongDescription" String="This value shall indicate a measurement of altitude, in meter units, and the ReadingUnits value shall be `m`."/>
        </Member>
        <Member Name="Percent">
          <Annotation Term="OData.Description" String="Percent."/>
          <Annotation Term="OData.LongDescription" String="This value shall indicate a percentage measurement, in percent units, and the ReadingUnits value shall be `%`."/>
          <Annotation Term="Redfish.Revisions">
            <Collection>
              <Record>
                <PropertyValue Property="Kind" EnumMember="Redfish.RevisionKind/Added"/>
                <PropertyValue Property="Version" String="v1_1_0"/>
              </Record>
            </Collection>
          </Annotation>
        </Member>
      </EnumType>
    </Schema>

    <Schema xmlns="http://docs.oasis-open.org/odata/ns/edm" Namespace="Sensor.v1_0_1">
      <Annotation Term="Redfish.OwningEntity" String="DMTF"/>
      <Annotation Term="OData.Description" String="This version was created to correct the ReadingUnits definition for the EnergykWh ReadingType and the EnergykWh and EnergyJoules descriptions.  It also forces the regeneration of JSON Schema so that URI properties use the uri-reference format, and to add a missing term on several properties to not allow them to be null."/>
      <EntityType Name="Sensor" BaseType="Sensor.v1_0_0.Sensor"/>
    </Schema>

    <Schema xmlns="http://docs.oasis-open.org/odata/ns/edm" Namespace="Sensor.v1_0_2">
      <Annotation Term="Redfish.OwningEntity" String="DMTF"/>
      <Annotation Term="OData.Description" String="This version was created to update descriptions that this schema defines."/>
      <EntityType Name="Sensor" BaseType="Sensor.v1_0_1.Sensor"/>
    </Schema>

    <Schema xmlns="http://docs.oasis-open.org/odata/ns/edm" Namespace="Sensor.v1_0_3">
      <Annotation Term="Redfish.OwningEntity" String="DMTF"/>
      <Annotation Term="OData.Description" String="This version was created to remove the excerpt annotation from the LoadPercent and PeakReading properties, and to provide a specific excerpt type for PhysicalContext and PhysicalSubContext.  It was also created to add unit annotations for ApparentVA and ReactiveVAR properties."/>
      <EntityType Name="Sensor" BaseType="Sensor.v1_0_2.Sensor"/>
    </Schema>

    <Schema xmlns="http://docs.oasis-open.org/odata/ns/edm" Namespace="Sensor.v1_0_4">
      <Annotation Term="Redfish.OwningEntity" String="DMTF"/>
      <Annotation Term="OData.Description" String="This version was created to correct the name of the ResetStatistics action to ResetMetrics for consistency.  It also removed the excerpt annotation from the Status and ReadingUnits properties for the base sensor excerpt definition."/>
      <EntityType Name="Sensor" BaseType="Sensor.v1_0_3.Sensor"/>
    </Schema>

    <Schema xmlns="http://docs.oasis-open.org/odata/ns/edm" Namespace="Sensor.v1_0_5">
      <Annotation Term="Redfish.OwningEntity" String="DMTF"/>
      <Annotation Term="OData.Description" String="This version was created to correct various typographical errors."/>
      <EntityType Name="Sensor" BaseType="Sensor.v1_0_4.Sensor"/>
    </Schema>

    <Schema xmlns="http://docs.oasis-open.org/odata/ns/edm" Namespace="Sensor.v1_1_0">
      <Annotation Term="Redfish.OwningEntity" String="DMTF"/>
      <Annotation Term="Redfish.Release" String="2019.4"/>
      <Annotation Term="OData.Description" String="This version was created to move the ElectricalContext and VoltageType EnumTypes to the unversioned namespace.  It adds properties related to electrical sensors, LifetimeReading, and an ImplementationType for a sensor.  It also deprecated the narrowly-defined LoadPercent property in favor of a more general usage of Reading with a ReadingType of Percent."/>

      <EntityType Name="Sensor" BaseType="Sensor.v1_0_4.Sensor">
        <Property Name="CrestFactor" Type="Edm.Decimal">
          <Annotation Term="OData.Permissions" EnumMember="OData.Permission/Read"/>
          <Annotation Term="OData.Description" String="The crest factor for this sensor."/>
          <Annotation Term="OData.LongDescription" String="This property shall contain the ratio of the peak measurement divided by the RMS measurement and calculated over same N line cycles.  A sine wave would have a value of 1.414."/>
          <Annotation Term="Redfish.Excerpt" String="Current,Voltage"/>
        </Property>
        <Property Name="THDPercent" Type="Edm.Decimal">
          <Annotation Term="OData.Permissions" EnumMember="OData.Permission/Read"/>
          <Annotation Term="OData.Description" String="The total harmonic distortion (THD)."/>
          <Annotation Term="OData.LongDescription" String="This property shall contain the total harmonic distortion of the Reading property in percent units."/>
          <Annotation Term="Redfish.Excerpt" String="Current,Voltage"/>
        </Property>
        <Property Name="LifetimeReading" Type="Edm.Decimal">
          <Annotation Term="OData.Permissions" EnumMember="OData.Permission/Read"/>
          <Annotation Term="OData.Description" String="The total accumulation value for this sensor."/>
          <Annotation Term="OData.LongDescription" String="This property shall contain the total accumulation of the Reading property over the sensor's life time.  This value shall not be reset by the ResetStatistics action."/>
          <Annotation Term="Redfish.Excerpt" String="EnergykWh"/>
        </Property>
        <Property Name="SensingInterval" Type="Edm.Duration">
          <Annotation Term="OData.Permissions" EnumMember="OData.Permission/Read"/>
          <Annotation Term="OData.Description" String="The time interval between readings of the sensor."/>
          <Annotation Term="OData.LongDescription" String="This property shall contain the time interval between readings of data from the sensor."/>
        </Property>
        <Property Name="ReadingTime" Type="Edm.DateTimeOffset">
          <Annotation Term="OData.Permissions" EnumMember="OData.Permission/Read"/>
          <Annotation Term="OData.Description" String="The date and time that the reading was acquired from the sensor."/>
          <Annotation Term="OData.LongDescription" String="This property shall contain the date and timetime that the reading data was acquired from the sensor.  This value is used to synchronize readings from multiple sensors, and does not represent the time at which the resource was accessed."/>
        </Property>
        <Property Name="Implementation" Type="Sensor.v1_1_0.ImplementationType">
          <Annotation Term="OData.Permissions" EnumMember="OData.Permission/Read"/>
          <Annotation Term="OData.Description" String="The implementation of the sensor."/>
          <Annotation Term="OData.LongDescription" String="This property shall contain the implementation of the sensor."/>
        </Property>
      </EntityType>

      <EnumType Name="ImplementationType">
        <Member Name="PhysicalSensor">
          <Annotation Term="OData.Description" String="The reading is acquired from a physical sensor."/>
        </Member>
        <Member Name="Synthesized">
          <Annotation Term="OData.Description" String="The reading is obtained by applying a calculation on one or more properties.  The calculation is not provided."/>
        </Member>
        <Member Name="Reported">
          <Annotation Term="OData.Description" String="The reading is obtained from software or a device."/>
        </Member>
      </EnumType>
    </Schema>

    <Schema xmlns="http://docs.oasis-open.org/odata/ns/edm" Namespace="Sensor.v1_1_1">
      <Annotation Term="Redfish.OwningEntity" String="DMTF"/>
      <Annotation Term="OData.Description" String="This version was created to correct various typographical errors."/>
      <EntityType Name="Sensor" BaseType="Sensor.v1_1_0.Sensor"/>
    </Schema>

  </edmx:DataServices>