iio: humidity: hdc3020: fix hysteresis representation
commit 9547d6a4c65e975e40e203900322342ef7379c52 upstream. According to the ABI docs hysteresis values are represented as offsets to threshold values. Current implementation represents hysteresis values as absolute values which is wrong. Nevertheless the device stores them as absolute values and the datasheet refers to them as clear thresholds. Fix the reading and writing of hysteresis values by including thresholds into calculations. Hysteresis values that result in threshold clear values that are out of limits will be truncated. To check that the threshold clear values are correct, registers are read out using i2ctransfer and the corresponding temperature and relative humidity thresholds are calculated using the formulas in the datasheet. Fixes: 3ad0e7e5f0cb ("iio: humidity: hdc3020: add threshold events support") Signed-off-by: Dimitri Fedrau <dima.fedrau@gmail.com> Reviewed-by: Javier Carrasco <javier.carrasco.cruz@gmail.com> Link: https://lore.kernel.org/r/20240605192136.38146-1-dima.fedrau@gmail.com Cc: <Stable@vger.kernel.org> Signed-off-by: Jonathan Cameron <Jonathan.Cameron@huawei.com> Signed-off-by: Greg Kroah-Hartman <gregkh@linuxfoundation.org>
-rw-r--r--drivers/iio/humidity/hdc3020.c325
1 files changed, 249 insertions, 76 deletions
diff --git a/drivers/iio/humidity/hdc3020.c b/drivers/iio/humidity/hdc3020.c
index 1e5d0d4797b1..1e702fcc4851 100644
--- a/drivers/iio/humidity/hdc3020.c
+++ b/drivers/iio/humidity/hdc3020.c
@@ -18,6 +18,7 @@
#include <linux/i2c.h>
#include <linux/init.h>
#include <linux/interrupt.h>
+#include <linux/math64.h>
#include <linux/module.h>
#include <linux/mutex.h>
#include <linux/units.h>
@@ -63,8 +64,10 @@
#define HDC3020_CRC8_POLYNOMIAL 0x31
-#define HDC3020_MIN_TEMP -40
-#define HDC3020_MAX_TEMP 125
+#define HDC3020_MIN_TEMP_MICRO -39872968
+#define HDC3020_MAX_TEMP_MICRO 124875639
+#define HDC3020_MAX_TEMP_HYST_MICRO 164748607
+#define HDC3020_MAX_HUM_MICRO 99220264
struct hdc3020_data {
struct i2c_client *client;
@@ -363,6 +366,105 @@ static int hdc3020_write_raw(struct iio_dev *indio_dev,
return -EINVAL;
}
+static int hdc3020_thresh_get_temp(u16 thresh)
+{
+ int temp;
+
+ /*
+ * Get the temperature threshold from 9 LSBs, shift them to get
+ * the truncated temperature threshold representation and
+ * calculate the threshold according to the formula in the
+ * datasheet. Result is degree celsius scaled by 65535.
+ */
+ temp = FIELD_GET(HDC3020_THRESH_TEMP_MASK, thresh) <<
+ HDC3020_THRESH_TEMP_TRUNC_SHIFT;
+
+ return -2949075 + (175 * temp);
+}
+
+static int hdc3020_thresh_get_hum(u16 thresh)
+{
+ int hum;
+
+ /*
+ * Get the humidity threshold from 7 MSBs, shift them to get the
+ * truncated humidity threshold representation and calculate the
+ * threshold according to the formula in the datasheet. Result is
+ * percent scaled by 65535.
+ */
+ hum = FIELD_GET(HDC3020_THRESH_HUM_MASK, thresh) <<
+ HDC3020_THRESH_HUM_TRUNC_SHIFT;
+
+ return hum * 100;
+}
+
+static u16 hdc3020_thresh_set_temp(int s_temp, u16 curr_thresh)
+{
+ u64 temp;
+ u16 thresh;
+
+ /*
+ * Calculate temperature threshold, shift it down to get the
+ * truncated threshold representation in the 9LSBs while keeping
+ * the current humidity threshold in the 7 MSBs.
+ */
+ temp = (u64)(s_temp + 45000000) * 65535ULL;
+ temp = div_u64(temp, 1000000 * 175) >> HDC3020_THRESH_TEMP_TRUNC_SHIFT;
+ thresh = FIELD_PREP(HDC3020_THRESH_TEMP_MASK, temp);
+ thresh |= (FIELD_GET(HDC3020_THRESH_HUM_MASK, curr_thresh) <<
+ HDC3020_THRESH_HUM_TRUNC_SHIFT);
+
+ return thresh;
+}
+
+static u16 hdc3020_thresh_set_hum(int s_hum, u16 curr_thresh)
+{
+ u64 hum;
+ u16 thresh;
+
+ /*
+ * Calculate humidity threshold, shift it down and up to get the
+ * truncated threshold representation in the 7MSBs while keeping
+ * the current temperature threshold in the 9 LSBs.
+ */
+ hum = (u64)(s_hum) * 65535ULL;
+ hum = div_u64(hum, 1000000 * 100) >> HDC3020_THRESH_HUM_TRUNC_SHIFT;
+ thresh = FIELD_PREP(HDC3020_THRESH_HUM_MASK, hum);
+ thresh |= FIELD_GET(HDC3020_THRESH_TEMP_MASK, curr_thresh);
+
+ return thresh;
+}
+
+static
+int hdc3020_thresh_clr(s64 s_thresh, s64 s_hyst, enum iio_event_direction dir)
+{
+ s64 s_clr;
+
+ /*
+ * Include directions when calculation the clear value,
+ * since hysteresis is unsigned by definition and the
+ * clear value is an absolute value which is signed.
+ */
+ if (dir == IIO_EV_DIR_RISING)
+ s_clr = s_thresh - s_hyst;
+ else
+ s_clr = s_thresh + s_hyst;
+
+ /* Divide by 65535 to get units of micro */
+ return div_s64(s_clr, 65535);
+}
+
+static int _hdc3020_write_thresh(struct hdc3020_data *data, u16 reg, u16 val)
+{
+ u8 buf[5];
+
+ put_unaligned_be16(reg, buf);
+ put_unaligned_be16(val, buf + 2);
+ buf[4] = crc8(hdc3020_crc8_table, buf + 2, 2, CRC8_INIT_VALUE);
+
+ return hdc3020_write_bytes(data, buf, 5);
+}
+
static int hdc3020_write_thresh(struct iio_dev *indio_dev,
const struct iio_chan_spec *chan,
enum iio_event_type type,
@@ -371,67 +473,126 @@ static int hdc3020_write_thresh(struct iio_dev *indio_dev,
int val, int val2)
{
struct hdc3020_data *data = iio_priv(indio_dev);
- u8 buf[5];
- u64 tmp;
- u16 reg;
- int ret;
-
- /* Supported temperature range is from –40 to 125 degree celsius */
- if (val < HDC3020_MIN_TEMP || val > HDC3020_MAX_TEMP)
- return -EINVAL;
-
- /* Select threshold register */
- if (info == IIO_EV_INFO_VALUE) {
- if (dir == IIO_EV_DIR_RISING)
- reg = HDC3020_S_T_RH_THRESH_HIGH;
- else
- reg = HDC3020_S_T_RH_THRESH_LOW;
+ u16 reg, reg_val, reg_thresh_rd, reg_clr_rd, reg_thresh_wr, reg_clr_wr;
+ s64 s_thresh, s_hyst, s_clr;
+ int s_val, thresh, clr, ret;
+
+ /* Select threshold registers */
+ if (dir == IIO_EV_DIR_RISING) {
+ reg_thresh_rd = HDC3020_R_T_RH_THRESH_HIGH;
+ reg_thresh_wr = HDC3020_S_T_RH_THRESH_HIGH;
+ reg_clr_rd = HDC3020_R_T_RH_THRESH_HIGH_CLR;
+ reg_clr_wr = HDC3020_S_T_RH_THRESH_HIGH_CLR;
} else {
- if (dir == IIO_EV_DIR_RISING)
- reg = HDC3020_S_T_RH_THRESH_HIGH_CLR;
- else
- reg = HDC3020_S_T_RH_THRESH_LOW_CLR;
+ reg_thresh_rd = HDC3020_R_T_RH_THRESH_LOW;
+ reg_thresh_wr = HDC3020_S_T_RH_THRESH_LOW;
+ reg_clr_rd = HDC3020_R_T_RH_THRESH_LOW_CLR;
+ reg_clr_wr = HDC3020_S_T_RH_THRESH_LOW_CLR;
}
guard(mutex)(&data->lock);
- ret = hdc3020_read_be16(data, reg);
+ ret = hdc3020_read_be16(data, reg_thresh_rd);
if (ret < 0)
return ret;
+ thresh = ret;
+ ret = hdc3020_read_be16(data, reg_clr_rd);
+ if (ret < 0)
+ return ret;
+
+ clr = ret;
+ /* Scale value to include decimal part into calculations */
+ s_val = (val < 0) ? (val * 1000000 - val2) : (val * 1000000 + val2);
switch (chan->type) {
case IIO_TEMP:
- /*
- * Calculate temperature threshold, shift it down to get the
- * truncated threshold representation in the 9LSBs while keeping
- * the current humidity threshold in the 7 MSBs.
- */
- tmp = ((u64)(((val + 45) * MICRO) + val2)) * 65535ULL;
- tmp = div_u64(tmp, MICRO * 175);
- val = tmp >> HDC3020_THRESH_TEMP_TRUNC_SHIFT;
- val = FIELD_PREP(HDC3020_THRESH_TEMP_MASK, val);
- val |= (FIELD_GET(HDC3020_THRESH_HUM_MASK, ret) <<
- HDC3020_THRESH_HUM_TRUNC_SHIFT);
+ switch (info) {
+ case IIO_EV_INFO_VALUE:
+ s_val = max(s_val, HDC3020_MIN_TEMP_MICRO);
+ s_val = min(s_val, HDC3020_MAX_TEMP_MICRO);
+ reg = reg_thresh_wr;
+ reg_val = hdc3020_thresh_set_temp(s_val, thresh);
+ ret = _hdc3020_write_thresh(data, reg, reg_val);
+ if (ret < 0)
+ return ret;
+
+ /* Calculate old hysteresis */
+ s_thresh = (s64)hdc3020_thresh_get_temp(thresh) * 1000000;
+ s_clr = (s64)hdc3020_thresh_get_temp(clr) * 1000000;
+ s_hyst = div_s64(abs(s_thresh - s_clr), 65535);
+ /* Set new threshold */
+ thresh = reg_val;
+ /* Set old hysteresis */
+ s_val = s_hyst;
+ fallthrough;
+ case IIO_EV_INFO_HYSTERESIS:
+ /*
+ * Function hdc3020_thresh_get_temp returns temperature
+ * in degree celsius scaled by 65535. Scale by 1000000
+ * to be able to subtract scaled hysteresis value.
+ */
+ s_thresh = (s64)hdc3020_thresh_get_temp(thresh) * 1000000;
+ /*
+ * Units of s_val are in micro degree celsius, scale by
+ * 65535 to get same units as s_thresh.
+ */
+ s_val = min(abs(s_val), HDC3020_MAX_TEMP_HYST_MICRO);
+ s_hyst = (s64)s_val * 65535;
+ s_clr = hdc3020_thresh_clr(s_thresh, s_hyst, dir);
+ s_clr = max(s_clr, HDC3020_MIN_TEMP_MICRO);
+ s_clr = min(s_clr, HDC3020_MAX_TEMP_MICRO);
+ reg = reg_clr_wr;
+ reg_val = hdc3020_thresh_set_temp(s_clr, clr);
+ break;
+ default:
+ return -EOPNOTSUPP;
+ }
break;
case IIO_HUMIDITYRELATIVE:
- /*
- * Calculate humidity threshold, shift it down and up to get the
- * truncated threshold representation in the 7MSBs while keeping
- * the current temperature threshold in the 9 LSBs.
- */
- tmp = ((u64)((val * MICRO) + val2)) * 65535ULL;
- tmp = div_u64(tmp, MICRO * 100);
- val = tmp >> HDC3020_THRESH_HUM_TRUNC_SHIFT;
- val = FIELD_PREP(HDC3020_THRESH_HUM_MASK, val);
- val |= FIELD_GET(HDC3020_THRESH_TEMP_MASK, ret);
+ s_val = (s_val < 0) ? 0 : min(s_val, HDC3020_MAX_HUM_MICRO);
+ switch (info) {
+ case IIO_EV_INFO_VALUE:
+ reg = reg_thresh_wr;
+ reg_val = hdc3020_thresh_set_hum(s_val, thresh);
+ ret = _hdc3020_write_thresh(data, reg, reg_val);
+ if (ret < 0)
+ return ret;
+
+ /* Calculate old hysteresis */
+ s_thresh = (s64)hdc3020_thresh_get_hum(thresh) * 1000000;
+ s_clr = (s64)hdc3020_thresh_get_hum(clr) * 1000000;
+ s_hyst = div_s64(abs(s_thresh - s_clr), 65535);
+ /* Set new threshold */
+ thresh = reg_val;
+ /* Try to set old hysteresis */
+ s_val = min(abs(s_hyst), HDC3020_MAX_HUM_MICRO);
+ fallthrough;
+ case IIO_EV_INFO_HYSTERESIS:
+ /*
+ * Function hdc3020_thresh_get_hum returns relative
+ * humidity in percent scaled by 65535. Scale by 1000000
+ * to be able to subtract scaled hysteresis value.
+ */
+ s_thresh = (s64)hdc3020_thresh_get_hum(thresh) * 1000000;
+ /*
+ * Units of s_val are in micro percent, scale by 65535
+ * to get same units as s_thresh.
+ */
+ s_hyst = (s64)s_val * 65535;
+ s_clr = hdc3020_thresh_clr(s_thresh, s_hyst, dir);
+ s_clr = max(s_clr, 0);
+ s_clr = min(s_clr, HDC3020_MAX_HUM_MICRO);
+ reg = reg_clr_wr;
+ reg_val = hdc3020_thresh_set_hum(s_clr, clr);
+ break;
+ default:
+ return -EOPNOTSUPP;
+ }
break;
default:
return -EOPNOTSUPP;
}
- put_unaligned_be16(reg, buf);
- put_unaligned_be16(val, buf + 2);
- buf[4] = crc8(hdc3020_crc8_table, buf + 2, 2, CRC8_INIT_VALUE);
- return hdc3020_write_bytes(data, buf, 5);
+ return _hdc3020_write_thresh(data, reg, reg_val);
}
static int hdc3020_read_thresh(struct iio_dev *indio_dev,
@@ -442,48 +603,60 @@ static int hdc3020_read_thresh(struct iio_dev *indio_dev,
int *val, int *val2)
{
struct hdc3020_data *data = iio_priv(indio_dev);
- u16 reg;
- int ret;
+ u16 reg_thresh, reg_clr;
+ int thresh, clr, ret;
- /* Select threshold register */
- if (info == IIO_EV_INFO_VALUE) {
- if (dir == IIO_EV_DIR_RISING)
- reg = HDC3020_R_T_RH_THRESH_HIGH;
- else
- reg = HDC3020_R_T_RH_THRESH_LOW;
+ /* Select threshold registers */
+ if (dir == IIO_EV_DIR_RISING) {
+ reg_thresh = HDC3020_R_T_RH_THRESH_HIGH;
+ reg_clr = HDC3020_R_T_RH_THRESH_HIGH_CLR;
} else {
- if (dir == IIO_EV_DIR_RISING)
- reg = HDC3020_R_T_RH_THRESH_HIGH_CLR;
- else
- reg = HDC3020_R_T_RH_THRESH_LOW_CLR;
+ reg_thresh = HDC3020_R_T_RH_THRESH_LOW;
+ reg_clr = HDC3020_R_T_RH_THRESH_LOW_CLR;
}
guard(mutex)(&data->lock);
- ret = hdc3020_read_be16(data, reg);
+ ret = hdc3020_read_be16(data, reg_thresh);
if (ret < 0)
return ret;
switch (chan->type) {
case IIO_TEMP:
- /*
- * Get the temperature threshold from 9 LSBs, shift them to get
- * the truncated temperature threshold representation and
- * calculate the threshold according to the formula in the
- * datasheet.
- */
- *val = FIELD_GET(HDC3020_THRESH_TEMP_MASK, ret);
- *val = *val << HDC3020_THRESH_TEMP_TRUNC_SHIFT;
- *val = -2949075 + (175 * (*val));
+ thresh = hdc3020_thresh_get_temp(ret);
+ switch (info) {
+ case IIO_EV_INFO_VALUE:
+ *val = thresh;
+ break;
+ case IIO_EV_INFO_HYSTERESIS:
+ ret = hdc3020_read_be16(data, reg_clr);
+ if (ret < 0)
+ return ret;
+
+ clr = hdc3020_thresh_get_temp(ret);
+ *val = abs(thresh - clr);
+ break;
+ default:
+ return -EOPNOTSUPP;
+ }
*val2 = 65535;
return IIO_VAL_FRACTIONAL;
case IIO_HUMIDITYRELATIVE:
- /*
- * Get the humidity threshold from 7 MSBs, shift them to get the
- * truncated humidity threshold representation and calculate the
- * threshold according to the formula in the datasheet.
- */
- *val = FIELD_GET(HDC3020_THRESH_HUM_MASK, ret);
- *val = (*val << HDC3020_THRESH_HUM_TRUNC_SHIFT) * 100;
+ thresh = hdc3020_thresh_get_hum(ret);
+ switch (info) {
+ case IIO_EV_INFO_VALUE:
+ *val = thresh;
+ break;
+ case IIO_EV_INFO_HYSTERESIS:
+ ret = hdc3020_read_be16(data, reg_clr);
+ if (ret < 0)
+ return ret;
+
+ clr = hdc3020_thresh_get_hum(ret);
+ *val = abs(thresh - clr);
+ break;
+ default:
+ return -EOPNOTSUPP;
+ }
*val2 = 65535;
return IIO_VAL_FRACTIONAL;
default: