summaryrefslogtreecommitdiff
path: root/arch/arm64/boot/dts/renesas/r8a77995.dtsi
diff options
context:
space:
mode:
authorKieran Bingham <kieran.bingham+renesas@ideasonboard.com>2018-09-25 19:33:35 +0300
committerSimon Horman <horms+renesas@verge.net.au>2018-09-26 12:13:39 +0300
commit0dc733988b813b4054e2243539855ef535d3c9dd (patch)
treee9523d46486db6947919a098421a6d9f2838de43 /arch/arm64/boot/dts/renesas/r8a77995.dtsi
parent13ee2bfc5444c8950d3c74bd47ff2a7b53c34aa6 (diff)
downloadlinux-0dc733988b813b4054e2243539855ef535d3c9dd.tar.xz
arm64: dts: renesas: r8a77995: Add LVDS support
The r8a77995 D3 platform has 2 LVDS channels connected to the DU. Signed-off-by: Kieran Bingham <kieran.bingham+renesas@ideasonboard.com> [uli: moved lvds* into the soc node, added PM domains, resets] Signed-off-by: Ulrich Hecht <uli+renesas@fpond.eu> Reviewed-by: Laurent Pinchart <laurent.pinchart@ideasonboard.com> Tested-by: Jacopo Mondi <jacopo+renesas@jmondi.org> Signed-off-by: Simon Horman <horms+renesas@verge.net.au>
Diffstat (limited to 'arch/arm64/boot/dts/renesas/r8a77995.dtsi')
-rw-r--r--arch/arm64/boot/dts/renesas/r8a77995.dtsi56
1 files changed, 56 insertions, 0 deletions
diff --git a/arch/arm64/boot/dts/renesas/r8a77995.dtsi b/arch/arm64/boot/dts/renesas/r8a77995.dtsi
index 89a04a4496fd..214f4954b321 100644
--- a/arch/arm64/boot/dts/renesas/r8a77995.dtsi
+++ b/arch/arm64/boot/dts/renesas/r8a77995.dtsi
@@ -972,12 +972,68 @@
port@1 {
reg = <1>;
du_out_lvds0: endpoint {
+ remote-endpoint = <&lvds0_in>;
};
};
port@2 {
reg = <2>;
du_out_lvds1: endpoint {
+ remote-endpoint = <&lvds1_in>;
+ };
+ };
+ };
+ };
+
+ lvds0: lvds-encoder@feb90000 {
+ compatible = "renesas,r8a77995-lvds";
+ reg = <0 0xfeb90000 0 0x20>;
+ clocks = <&cpg CPG_MOD 727>;
+ power-domains = <&sysc R8A77995_PD_ALWAYS_ON>;
+ resets = <&cpg 727>;
+ status = "disabled";
+
+ ports {
+ #address-cells = <1>;
+ #size-cells = <0>;
+
+ port@0 {
+ reg = <0>;
+ lvds0_in: endpoint {
+ remote-endpoint = <&du_out_lvds0>;
+ };
+ };
+
+ port@1 {
+ reg = <1>;
+ lvds0_out: endpoint {
+ };
+ };
+ };
+ };
+
+ lvds1: lvds-encoder@feb90100 {
+ compatible = "renesas,r8a77995-lvds";
+ reg = <0 0xfeb90100 0 0x20>;
+ clocks = <&cpg CPG_MOD 727>;
+ power-domains = <&sysc R8A77995_PD_ALWAYS_ON>;
+ resets = <&cpg 726>;
+ status = "disabled";
+
+ ports {
+ #address-cells = <1>;
+ #size-cells = <0>;
+
+ port@0 {
+ reg = <0>;
+ lvds1_in: endpoint {
+ remote-endpoint = <&du_out_lvds1>;
+ };
+ };
+
+ port@1 {
+ reg = <1>;
+ lvds1_out: endpoint {
};
};
};