diff --git a/Documentation/ABI/testing/sysfs-bus-iio-temperature-max31856 b/Documentation/ABI/testing/sysfs-bus-iio-temperature-max31856 deleted file mode 100644 index e5ef6d8e5da1..000000000000 --- a/Documentation/ABI/testing/sysfs-bus-iio-temperature-max31856 +++ /dev/null @@ -1,31 +0,0 @@ -What: /sys/bus/iio/devices/iio:deviceX/fault_oc -KernelVersion: 5.1 -Contact: linux-iio@vger.kernel.org -Description: - Open-circuit fault. The detection of open-circuit faults, - such as those caused by broken thermocouple wires. - Reading returns either '1' or '0'. - - === ======================================================= - '1' An open circuit such as broken thermocouple wires - has been detected. - '0' No open circuit or broken thermocouple wires are detected - === ======================================================= - -What: /sys/bus/iio/devices/iio:deviceX/fault_ovuv -KernelVersion: 5.1 -Contact: linux-iio@vger.kernel.org -Description: - Overvoltage or Undervoltage Input Fault. The internal circuitry - is protected from excessive voltages applied to the thermocouple - cables by integrated MOSFETs at the T+ and T- inputs, and the - BIAS output. These MOSFETs turn off when the input voltage is - negative or greater than VDD. - - Reading returns either '1' or '0'. - - === ======================================================= - '1' The input voltage is negative or greater than VDD. - '0' The input voltage is positive and less than VDD (normal - state). - === ======================================================= |