fru-fault-monitor: Enable OperationalStatus monitor feature
Currently, the phosphor-fru-fault-monitor updates the Asserted property of the Led Group D-Bus object by monitoring the `/xyz/openbmc_project/logging` object path. The intent behind this commit is to add another way to monitor the `xyz.openbmc_project.State.Decorator.OperationalStatus` interface of the Inventory D-Bus object, and check whether the Inventory D-Bus object is associated with the LED group D-Bus object, and then update the Asserted property of the LedManager. Since both these methods handle the faults differently, Only ONE of these 2 methods can be enabled and NOT both. The first way is supported by default. To turn OFF the default way AND turn ON this second way, Enable monitor-operational-status. Change-Id: I03701e599b6a120bc1f83da6f473b12f38660d64 Signed-off-by: Vishwanatha Subbanna <vishwa@linux.vnet.ibm.com>